Schneider Electric A9E18320 iIL Red Indicator Light 110-230 V

Description

A9E18320 Acti9 iIL red indicator light: purpose and product description

The A9E18320 is a Schneider Electric Acti9 iIL modular pilot light with a single red LED. It is built into a standard DIN-rail module, two 9 mm pitches wide, so a status lamp can sit in the same row as the circuit breakers it reports on. The datasheet lists a rated supply voltage of 110 to 230 V AC at 50/60 Hz or 110 to 130 V DC. Seven Star LLC supplies the A9E18320 in Oman and the GCC as an independent supplier based in Muscat.

A pilot light is the simplest status device in a distribution board. A lit lamp confirms that a circuit has voltage, that a protective device has not tripped, or that a function is active. The red colour is normally chosen for alarms or for a live-state warning, and the LED type removes the need for lamp replacement in service.

Technical specifications of the A9E18320

Parameter Specification
Manufacturer / part number Schneider Electric / A9E18320
Description Acti9 iIL single indicator light – Red – 110-230 Vac
Range of product Acti9
Product name Acti9 iIL
Product or component type Modular pilot light
Device short name iIL
[Us] rated supply voltage 110 to 230 V AC at 50/60 Hz; 110 to 130 V DC
Indicator light 1 LED red, service life 100000 h of constant lighting efficiency (consumption 0.3 W)
Mounting mode Fixed
Mounting support Symmetrical DIN rail
Comb busbar and distribution Upside: ProDis
9 mm pitches 2
Height 82 mm
Width 18 mm
Depth 69.5 mm
Auxiliary connection terminal Tunnel type terminal 1 cable(s) rigid 0.5 mm²; Tunnel type terminal 2 cable(s) rigid 2.5 mm²; Tunnel type terminal 1 cable(s) flexible 0.5 mm²
Tightening torque 1 N.m
Standards IEC 60947-5-1
IP degree of protection IP2; IPxx B
Relative humidity 95 % at 55 °C
Ambient air temperature, operation -35 to 70 °C
Ambient air temperature, storage -40 to 80 °C

Supply voltage and LED data of the A9E18320

The wide supply window is one of the most practical features of the A9E18320: the same module serves a 110 V circuit, a 230 V circuit and, on DC, a 110 to 130 V control supply, so one stock item covers several panels. The datasheet quotes the indicator as one red LED with a service life of 100,000 hours of constant light efficiency and a consumption of 0.3 W.

A consumption of 0.3 W is low enough that a dozen lamps on a board add less than 4 W of continuous load, and the heat is negligible inside the enclosure. The long LED life means that the lamp is not the part that needs a maintenance visit; a lit-or-dark status is available for the working life of the board.

Mounting, wiring and comb busbar compatibility of the A9E18320

The A9E18320 is mounted on a symmetrical DIN rail in the fixed mounting mode, with a height of 82 mm, a width of 18 mm and a depth of 69.5 mm. The colour is white (RAL 9003). The datasheet lists comb busbar and distribution block compatibility as the upside ProDis connection, which means the supply can be taken from a compatible busbar on the top instead of wiring the module by hand.

The auxiliary connection terminal is a tunnel type, taking one rigid conductor of 0.5 mm squared or two of 2.5 mm squared, as well as flexible conductors with and without ferrules, with a 9 mm stripping length and a 1 N.m tightening torque. For a pilot light the cross-section is more than sufficient; the practical point is to keep conductors short and tidy so that the row remains easy to read.

Protection degree and environment for the A9E18320

Protection is listed as IP2 with IPxx B, and the standard referenced is IEC 60947-5-1. This is a finger-safe, indoor, in-enclosure product: it expects the board door or cover to provide dust and moisture protection. Pollution degree 3 and tropicalisation 2 are listed, with relative humidity of 95 percent at 55 degrees C.

The ambient range is -35 to 70 °C for operation and -40 to 80 °C for storage. The upper operating limit of 70 degrees C is generous compared with many modular devices, but an LED lamp at the top of a hot board still ages faster, so a spare location at a lower row is preferable for lamps that must last.

Choosing a pilot light: the A9E18320 against other indicators

Not every indication task needs the same device. A single LED lamp such as the A9E18320 suits plain voltage presence or a simple alarm. When a board needs to show several states, or a mix of colours, a row of lamps in different colours is common, and combined indicators and push-buttons exist in other ranges. When a circuit must be monitored remotely, a lamp is not enough and an auxiliary contact or a communication-enabled device is needed.

The red colour also has a convention attached. In control panels red normally signals a fault, a stop or a warning condition, while green is used for running or healthy states. Picking a colour that matches the rest of the plant avoids confusion for operators who walk between several boards.

Typical uses of the A9E18320 in Oman and the GCC

In Gulf buildings the iIL red lamp is typically fitted next to a surge protection device or a main breaker to show that the supply is present, or beside a group of circuits that are fed from a stand-by source so that staff can see when the stand-by supply is active. In pumping and water-treatment panels it is used as a general alarm lamp for a circuit that should normally be dark.

Because the supply can be 110 to 230 V AC, the lamp can be placed across the line and neutral of the circuit it watches without a transformer. In hot, dusty outdoor boards the main care is the enclosure: with only IP2 on the module, door seals and filters protect the lamp, not the lamp itself.

Selection checklist for the A9E18320

  • Supply voltage of the circuit to be watched: 110 to 230 V AC or 110 to 130 V DC
  • Colour: red; other colours are different references
  • Space: two 9 mm pitches with 69.5 mm depth
  • Connection: tunnel terminal with 1 N.m torque, or a comb busbar on the upside
  • Environment: IP2, closed enclosure, ambient range as given

Information to send with an RFQ for the A9E18320

  • Reference (A9E18320) and quantity
  • Circuit voltage and whether AC or DC
  • Board type and the busbar system in use
  • Delivery location and timing
  • Spare or new-project purchase

Documents and quotation

A datasheet for the A9E18320 is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it should be read together with the manufacturer’s installation instructions for the final design.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Datasheets & Documents
  • PDF Datasheet Schneider Electric A9E18320 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric A9E18320 iIL Red Indicator Light

Answers from our engineering team on installation, compatibility and integration.

01What coil or control voltage does the A9E18320 use?
The datasheet lists 110 to 230 V AC at 50/60 Hz, 110 to 130 V DC. Check this against the real control supply before ordering.
02What are the dimensions of the A9E18320?
The datasheet gives a width of 18 mm; see the table above for height and depth.
03How is the A9E18320 mounted?
The datasheet gives: Symmetrical DIN rail.
04What ambient temperature range is listed for the A9E18320?
The datasheet lists -35 to 70 °C in operation and -40 to 80 °C in storage. In hot Gulf plant rooms the operating upper limit should be compared with the real panel temperature.
05What ingress protection does the A9E18320 have?
The datasheet states IP2, IPxx B, so it belongs inside a closed enclosure.