Description

RPZF2 relay socket: what it is

RPZF2 is a 16 A mixed-contact socket for two-pole RPM power relays. In the Schneider Electric Harmony Electromechanical Relays range it belongs to the RPZ socket line, and the datasheet records the compatible relay as: Plug-in relay RPM with 2 C/O contact.

A socket like this is the part of a relay installation that outlasts relays: it carries the wiring, takes the clip-in relay and lets a failed relay be swapped without touching a single conductor. Sockets in this family look alike, so check the part number against the relay series and contact count before ordering.

Seven Star LLC supplies RPZF2 in Oman and the GCC as an independent industrial supplier in Muscat; the datasheet we hold is dated 8 Nov 2026.

Relays and parts that go with RPZF2

The socket pairs with RPM relays carrying 2 C/O contacts, such as RPM22BD (24 V DC) and RPM22P7 (230 V AC); the larger RPZF4 is the equivalent for the four-pole RPM relay.

For reference, the compatibility entry in the RPZF2 datasheet reads: Plug-in relay RPM with 2 C/O contact. Where a project needs a time function, the RUW101MW multifunction timer module lists sockets of the RPZ and RUZ lines as compatible; check its own datasheet for the exact sockets that apply.

Information to send with an RFQ

To quote correctly we need:

  • Part number RPZF2 and the quantity.
  • The relay part number that will sit in the socket.
  • Wire size, ferrule use and panel or rail mounting.
  • Delivery location in Oman or the GCC and any project reference.

Socket family comparison

Socket Relay Thermal current Width
RPZF2 (this page) RPM 2 C/O 16 A 30 mm
RPZF4 RPM 4 C/O 16 A 50 mm
RSZE1S48M RSB 2 C/O 10 A 15.5 mm
RUZC3M RUM 3 C/O 10 A 38 mm
RUZSC3M RUM 3 C/O 12 A 36 mm

Wiring and terminal details

The datasheet lists these conductor sizes for RPZF2: – screw clamp terminals, flexible cable with cable end 1 × 0.5–1 × 2.5 mm² / 20 AWG–14 AWG – screw clamp terminals, solid cable without cable end 1 × 0.5–1 × 1.5 mm² / 20 AWG–16 AWG – screw clamp terminals, flexible cable with cable end 2 × 0.5–2 × 2.5 mm² / 20 AWG–14 AWG – screw clamps terminals, solid cable without cable end 2 × 0.5–2 × 1.5 mm² / 20 AWG–16 AWG. Tighten to the value stated, which is < 1 N.m for M3.5 screw(s), and use ferrules on stranded wire in line with the flexible-with-cable-end entries.

The contact terminal arrangement is described as mixed and the pin shape as flat. That pin shape must match the relay, so the lockable test button on the relay is reachable from the front once it is plugged in.

Selection and ordering checklist for RPZF2

Confirm the following before you order RPZF2:

  • The relay type and contact count must match: this socket is for 2 C/O RPM relays.
  • Current: the datasheet gives 16 A conventional free-air thermal current and operational voltage < 250 V.
  • Width on the rail: 30 mm; net weight 0.054 kg.
  • Wire sizes and whether ferrules are fitted, against the terminal table above.
  • Packaging: the datasheet shows a sale quantity of 10, so confirm how many you need.

Installation and maintenance notes

This unit can be fixed by panel screws or clipped onto a 35 mm symmetrical rail. The listed ambient range is -40–55 °C for operation and -40–85 °C for storage; IP20 on the socket means it belongs inside an enclosure.

Good practice is to identify each socket on the panel drawing, retorque terminals after the first thermal cycle, and inspect for discoloured terminals at routine shutdowns. A failed relay is replaced by unplugging it; the socket stays wired, which keeps downtime short.

Typical use of RPZF2 in Oman and the GCC

Typical uses are racks of power relays that switch contactor coils, solenoid valves, alarm horns and heaters in utility panels. Such panels are found in power stations, desalination plants, oil and gas facilities and building services across Oman, usually in air-conditioned rooms or sealed cabinets.

The datasheet limits operation to -40–55 °C and lists pollution degree 3 and overvoltage category III; heat build-up in sun-exposed enclosures and dust ingress through poor cable entries are the practical risks to design around.

RPZF2 technical specifications

Parameter Specification
Manufacturer / part number Schneider Electric / RPZF2
Product type Socket for plug-in relay (RPM series)
Compatible relays Plug-in relay RPM with 2 C/O contact
Contacts 2 C/O
Thermal current (free air) 16 A
Rated operational voltage < 250 V
Contact terminal arrangement Mixed
Pin shape Flat
Terminals – screw clamp terminals, flexible cable with cable end 1 × 0.5–1 × 2.5 mm² / 20 AWG–14 AWG – screw clamp terminals, solid cable without cable end 1 × 0.5–1 × 1.5 mm² / 20 AWG–16 AWG – screw clamp terminals, flexible cable with cable end 2 × 0.5–2 × 2.5 mm² / 20 AWG–14 AWG – screw clamps terminals, solid cable without cable end 2 × 0.5–2 × 1.5 mm² / 20 AWG–16 AWG
Tightening torque < 1 N.m for M3.5 screw(s)
Fixing By screw (panel); Clip-on (35 mm symmetrical DIN rail)
Impulse withstand 4 kV
Overvoltage category / pollution degree III / 3
Width / net weight 30 mm / 0.054 kg
Sold in multiples of 10
Protection IP20 conforming to IEC 60529
Standard IEC 61984
Certifications UL; CSA
Operating / storage temperature -40–55 °C / -40–85 °C

Documents and quotation

The datasheet for this unit is attached to this page (document dated 8 Nov 2026). Please treat it as the reference for every figure above, and tell us if your project specification asks for anything the datasheet does not state.

Send the part number, quantity, required delivery point and any project reference through the quotation form or by email. Seven Star LLC is an independent industrial supplier based in Muscat, serving customers across Oman and the GCC, and we reply with availability and lead time for this exact part number.

Datasheets & Documents
  • PDF Datasheet Schneider Electric RPZF2 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric RPZF2 Socket for RPM2 Relays

Answers from our engineering team on installation, compatibility and integration.

01Which relays fit RPZF2?
The datasheet lists Plug-in relay RPM with 2 C/O contact. Always match the relay series and contact count.
02What current is RPZF2 rated for?
The conventional free-air thermal current is 16 A, with rated operational voltage < 250 V.
03How is RPZF2 mounted?
By panel screws or clip-on to a 35 mm symmetrical DIN rail; it is 30 mm wide.
04What terminals does RPZF2 use?
Screw terminals with the conductor sizes shown in the specification table; tightening torque is < 1 N.m for M3.5 screw(s).
05What temperature range applies to RPZF2?
Operation -40–55 °C, storage -40–85 °C; protection is IP20.