Schneider Electric LA1KN04 TeSys K 4 NC Front Contact Block

Description

LA1KN04: four normally closed contacts in one TeSys K block

The LA1KN04 is a Schneider Electric TeSys K auxiliary contact block with four normally closed contacts in one front-mount housing. It gives a safety-minded panel several series permissive contacts from a single accessory. Seven Star LLC supplies the LA1KN04 in Oman and the GCC as an independent supplier based in Muscat.

The 04 in the reference is the contact count: no NO and four NC. The block is still 30 mm by 38 mm by 35 mm per the datasheet, the same envelope as the two-contact and mixed versions, which is what makes it a space-saver.

Technical specifications of the LA1KN04

Parameter Specification
Manufacturer / part number Schneider Electric / LA1KN04
Description Product datasheet Auxiliary contact block, TeSys K, 4NC, front mounting, screw clamp terminals
Range TeSys
Product name TeSys K
Product or component type Auxiliary contact block
Device short name LA1
Range compatibility TeSys K LC1K; TeSys K CA2K; TeSys K CA3K
Mounting location Front
Pole contact composition 4 NC
Contacts operation Instantaneous
[Ue] rated operational voltage 690 V AC 25 to 400 Hz
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1
[Ith] conventional free air thermal 10 A (at 50 °C)
Standards EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; JIS C8201-5-1; UL 60335-2-40:Annex JJ
Product certifications CB Scheme; CCC; UL; CSA; CE; UKCA
Irms rated making capacity 110 A at <= 690 V AC conforming to IEC 60947
Permissible short-time rating 80 A 1 s; 60 A 500 ms; 110 A 100 ms
Associated fuse rating 10 A gG at <= 690 V conforming to IEC 60947
Minimum switching current 5 mA
Minimum switching voltage 17 V
Non overlap distance 0.5 mm
Insulation resistance > 10 MOhm; are subject to change – check with your local distributor.
Connections – terminals Screw clamp terminals 1 cable(s) 0.34 to 1.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 0.75 to 4 mm²flexible without cable end
Height 30 mm
Width 38 mm
Depth 35 mm
Net weight 0.045 kg
Environmental characteristic Normal environment
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature (operation, as listed) -25 to 50 °C
Operating altitude 2000 m

When four NC contacts on the LA1KN04 are the right answer

A four-NC block is a good fit where one contactor must supply several independent permissive contacts, for example in an interlock chain that crosses a main circuit, a signal circuit and two alarm circuits. It avoids stacking two blocks and gives a cleaner terminal layout.

Remember that all four contacts open together when the contactor closes. If any circuit needs a closing contact at the same moment, a mixed block such as the LA1KN13 is the better pick.

Checklist for the LA1KN04

  • Four NC, no NO contact in the block.
  • Check the contactor model against LC1K, CA2K and CA3K.
  • Confirm the control voltages in each circuit are within 690 V AC.
  • Keep the circuits’ total heat in mind in a closed cabinet.
  • Use the LA1KN40 if four NO contacts are needed instead.

LA1KN04 compatibility and electrical limits

The datasheet range compatibility is TeSys K LC1K and the relays CA2K and CA3K. The block mounts on the front face.

Ratings are listed once for the whole four-pole block: 690 V AC, 10 A thermal at 50 °C, 10 A gG fuse protection. All four circuits therefore share the same limits and the same housing.

The datasheet describes a front-mounting block with screw clamp terminals, 30 mm high, 38 mm wide and 35 mm deep, weighing 0.045 kg. Rated operational voltage is 690 V AC at 25 to 400 Hz, conventional thermal current is 10 A at 50 °C, and the associated fuse is 10 A gG up to 690 V. Rated making capacity is 110 A, with short-time ratings of 80 A for 1 s, 60 A for 500 ms and 110 A for 100 ms. Minimum switching is 5 mA at 17 V, and the non-overlap distance between NC and NO contacts is 0.5 mm.

LA1KN04 uses in Oman and the GCC

Interlocked gate and shutter drives, small pump control panels and hoist controls make use of multiple NC contacts. In plants with strict permissive logic, such as fuel handling or chemical dosing skids, a four-NC block can feed several permissive loops from one contactor.

Panels in the Gulf run hot, so use the ambient limit from the datasheet as a hard design number.

LA1KN contact block family compared with the LA1KN04

The five TeSys K references below differ only in the arrangement of contacts. The highlighted row is the page you are reading.

Reference Contacts Compatible with
LA1KN02 2 NC LC1K; CA2K; CA3K; CA4K
LA1KN04 4 NC LC1K; CA2K; CA3K
LA1KN13 1 NO + 3 NC LC1K; CA2K; CA3K
LA1KN20 2 NO LC1K; CA2K; CA3K; CA4K
LA1KN40 4 NO LC1K; CA2K; CA3K

Wiring practice for the LA1KN04

Eight screw clamp terminals demand tidy cabling. Use ferrules on 0.34 to 1.5 mm² flexible wire, tighten to 1.3 N.m and tug-test each lead.

A numbering plan per contact avoids mistakes. Test each of the four circuits individually, both with the contactor open and closed.

Information to send with an RFQ for the LA1KN04

  • Full reference and quantity required
  • Contactor or relay model the block mounts on
  • Contact arrangement needed (NO and NC count)
  • Control voltage and load of each circuit
  • Delivery location and timing

Documents and quotation

A datasheet for the LA1KN04 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.

Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Tesys K Aux Range

Seven Star LLC supplies models from the Se Tesys K Aux range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric LA1KN02 TeSys K 2 NC Front Contact BlockContactors & Overload RelaysView details
Schneider Electric LA1KN04 TeSys K 4 NC Front Contact BlockContactors & Overload RelaysYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric LA1KN04 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LA1KN04 TeSys K 4 NC Front

Answers from our engineering team on installation, compatibility and integration.

01How many contacts does the LA1KN04 have?
Four normally closed contacts. Check that this arrangement matches your control circuit before ordering.
02Which contactors does the LA1KN04 fit?
TeSys K LC1K and the CA2K and CA3K relays, per the datasheet.
03What size is the LA1KN04?
30 mm high, 38 mm wide and 35 mm deep. See the datasheet linked on this page for the full figures.
04What is the making capacity of the LA1KN04?
110 A at up to 690 V AC. See the datasheet linked on this page for the full figures.
05What is the net weight of the LA1KN04?
0.045 kg. See the datasheet linked on this page for the full figures.