Brand: Schneider Electric
Schneider Electric LA1KN04 TeSys K 4 NC Front Contact Block
Description
LA1KN04: four normally closed contacts in one TeSys K block
The LA1KN04 is a Schneider Electric TeSys K auxiliary contact block with four normally closed contacts in one front-mount housing. It gives a safety-minded panel several series permissive contacts from a single accessory. Seven Star LLC supplies the LA1KN04 in Oman and the GCC as an independent supplier based in Muscat.
The 04 in the reference is the contact count: no NO and four NC. The block is still 30 mm by 38 mm by 35 mm per the datasheet, the same envelope as the two-contact and mixed versions, which is what makes it a space-saver.
Technical specifications of the LA1KN04
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LA1KN04 |
| Description | Product datasheet Auxiliary contact block, TeSys K, 4NC, front mounting, screw clamp terminals |
| Range | TeSys |
| Product name | TeSys K |
| Product or component type | Auxiliary contact block |
| Device short name | LA1 |
| Range compatibility | TeSys K LC1K; TeSys K CA2K; TeSys K CA3K |
| Mounting location | Front |
| Pole contact composition | 4 NC |
| Contacts operation | Instantaneous |
| [Ue] rated operational voltage | 690 V AC 25 to 400 Hz |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1 |
| [Ith] conventional free air thermal | 10 A (at 50 °C) |
| Standards | EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; JIS C8201-5-1; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; CCC; UL; CSA; CE; UKCA |
| Irms rated making capacity | 110 A at <= 690 V AC conforming to IEC 60947 |
| Permissible short-time rating | 80 A 1 s; 60 A 500 ms; 110 A 100 ms |
| Associated fuse rating | 10 A gG at <= 690 V conforming to IEC 60947 |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non overlap distance | 0.5 mm |
| Insulation resistance | > 10 MOhm; are subject to change – check with your local distributor. |
| Connections – terminals | Screw clamp terminals 1 cable(s) 0.34 to 1.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 0.75 to 4 mm²flexible without cable end |
| Height | 30 mm |
| Width | 38 mm |
| Depth | 35 mm |
| Net weight | 0.045 kg |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature (operation, as listed) | -25 to 50 °C |
| Operating altitude | 2000 m |
When four NC contacts on the LA1KN04 are the right answer
A four-NC block is a good fit where one contactor must supply several independent permissive contacts, for example in an interlock chain that crosses a main circuit, a signal circuit and two alarm circuits. It avoids stacking two blocks and gives a cleaner terminal layout.
Remember that all four contacts open together when the contactor closes. If any circuit needs a closing contact at the same moment, a mixed block such as the LA1KN13 is the better pick.
Checklist for the LA1KN04
- Four NC, no NO contact in the block.
- Check the contactor model against LC1K, CA2K and CA3K.
- Confirm the control voltages in each circuit are within 690 V AC.
- Keep the circuits’ total heat in mind in a closed cabinet.
- Use the LA1KN40 if four NO contacts are needed instead.
LA1KN04 compatibility and electrical limits
The datasheet range compatibility is TeSys K LC1K and the relays CA2K and CA3K. The block mounts on the front face.
Ratings are listed once for the whole four-pole block: 690 V AC, 10 A thermal at 50 °C, 10 A gG fuse protection. All four circuits therefore share the same limits and the same housing.
The datasheet describes a front-mounting block with screw clamp terminals, 30 mm high, 38 mm wide and 35 mm deep, weighing 0.045 kg. Rated operational voltage is 690 V AC at 25 to 400 Hz, conventional thermal current is 10 A at 50 °C, and the associated fuse is 10 A gG up to 690 V. Rated making capacity is 110 A, with short-time ratings of 80 A for 1 s, 60 A for 500 ms and 110 A for 100 ms. Minimum switching is 5 mA at 17 V, and the non-overlap distance between NC and NO contacts is 0.5 mm.
LA1KN04 uses in Oman and the GCC
Interlocked gate and shutter drives, small pump control panels and hoist controls make use of multiple NC contacts. In plants with strict permissive logic, such as fuel handling or chemical dosing skids, a four-NC block can feed several permissive loops from one contactor.
Panels in the Gulf run hot, so use the ambient limit from the datasheet as a hard design number.
LA1KN contact block family compared with the LA1KN04
The five TeSys K references below differ only in the arrangement of contacts. The highlighted row is the page you are reading.
| Reference | Contacts | Compatible with |
|---|---|---|
| LA1KN02 | 2 NC | LC1K; CA2K; CA3K; CA4K |
| LA1KN04 | 4 NC | LC1K; CA2K; CA3K |
| LA1KN13 | 1 NO + 3 NC | LC1K; CA2K; CA3K |
| LA1KN20 | 2 NO | LC1K; CA2K; CA3K; CA4K |
| LA1KN40 | 4 NO | LC1K; CA2K; CA3K |
Wiring practice for the LA1KN04
Eight screw clamp terminals demand tidy cabling. Use ferrules on 0.34 to 1.5 mm² flexible wire, tighten to 1.3 N.m and tug-test each lead.
A numbering plan per contact avoids mistakes. Test each of the four circuits individually, both with the contactor open and closed.
Information to send with an RFQ for the LA1KN04
- Full reference and quantity required
- Contactor or relay model the block mounts on
- Contact arrangement needed (NO and NC count)
- Control voltage and load of each circuit
- Delivery location and timing
Documents and quotation
A datasheet for the LA1KN04 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.
Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Tesys K Aux Range
Seven Star LLC supplies models from the Se Tesys K Aux range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric LA1KN02 TeSys K 2 NC Front Contact Block | Contactors & Overload Relays | View details |
| Schneider Electric LA1KN04 TeSys K 4 NC Front Contact Block | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric LA1KN04 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LA1KN04 TeSys K 4 NC Front
Answers from our engineering team on installation, compatibility and integration.
01How many contacts does the LA1KN04 have?
Four normally closed contacts. Check that this arrangement matches your control circuit before ordering.
02Which contactors does the LA1KN04 fit?
TeSys K LC1K and the CA2K and CA3K relays, per the datasheet.
03What size is the LA1KN04?
30 mm high, 38 mm wide and 35 mm deep. See the datasheet linked on this page for the full figures.
04What is the making capacity of the LA1KN04?
110 A at up to 690 V AC. See the datasheet linked on this page for the full figures.
05What is the net weight of the LA1KN04?
0.045 kg. See the datasheet linked on this page for the full figures.