Michell QMA601-LR Low-Range Moisture Analyzer 0.02 to 100 ppmV

Description

Michell QMA601-LR overview: low-range trace moisture analyzer for hazardous areas

Michell QMA601-LR is the parent order code of the low-range version of the Michell QMA601 process moisture analyzer. The datasheet describes a measurement range of 0.02 to 100 ppmV, trending to 2000 ppmV, with accuracy of plus or minus 0.03 ppmV or plus or minus 10 percent of reading, whichever is greater.

It uses the same fast-response quartz crystal microbalance technology, an internal moisture generator of about 0.5 ppmV that is traceable to NPL and NIST, and an Exd flameproof enclosure. The manufacturer states it is maintenance free for three years and that it is suitable for natural gas containing up to 20 percent hydrogen.

It is aimed at molecular sieve dehydration, LNG production and NGL extraction, where the moisture limits are very low.

The image shows the QMA601 analyzer in a sampling system from the manufacturer datasheet, the family of the low-range version.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Michell QMA601-LR so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.

Key features of QMA601-LR

  • Low-range measurement from 0.02 to 100 ppmV with a limit of detection of 0.02 ppmV.
  • Accuracy of plus or minus 0.03 ppmV or 10 percent of reading, whichever is greater.
  • Repeatability of plus or minus 5 percent of reading from 0.3 to 100 ppmV.
  • Built-in verification of customer process gas and internal moisture generator of about 0.5 ppmV.
  • Colour touch-screen HMI that needs no hot work permit, and 14 internal alarms.
  • IECEx, ATEX, UKCA and TR CU Ex certified for Exd flameproof use; cQPSus certified for explosion proof.

QMA601-LR technical specifications

The table below lists values published by the manufacturer for the product family of QMA601-LR. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.

Parameter Value
Order code (parent) QMA601-LR, QMA601 low-range analyzer
Technology Fast-response quartz crystal microbalance
Calibrated range 0.02 to 100 ppmV, traceable to NPL and NIST
Measurement range 0.02 to 100 ppmV, trending to 2000 ppmV
Accuracy Plus or minus 0.03 ppmV or plus or minus 10 percent of reading, whichever is greater
Repeatability Plus or minus 5 percent of reading from 0.3 to 100 ppmV
Limit of detection 0.02 ppmV
Sensitivity 0.01 ppmV or 1 percent of reading
Inlet and outlet pressure 2 barg and 1 barg
Sample flow 300 ml/min total flow
Sample gas temperature 0 to plus 100 degC
Enclosure GUB flameproof Exd, cast copper-free aluminium LM25, IP66, NEMA 4

Typical applications of QMA601-LR in Oman and the GCC

  • Molecular sieve dehydration of natural gas.
  • LNG production and NGL extraction.
  • Natural gas containing up to 20 percent hydrogen.

For operators in Oman and the GCC, process analyzers of this type are used where quality, safety or custody transfer depends on a defined gas composition: natural gas conditioning and export, glycol and molecular sieve dehydration units, LNG trains, refinery recycle gas, hydrogen and inert gas systems, and power generation fuel gas. Remote sites with high ambient temperatures need analyzers that are properly housed, certified for the area class, and supported with spares, which is why exact part numbers such as QMA601-LR matter.

Selection and compatibility notes

The QMA601-LR order string chooses the hazardous configuration, A for ATEX/IECEx and B for cQPSus at 24 V DC. An example on the sheet is QMA601-LR-A. Material certificates are separate lines.

For moisture above 100 ppmV, the standard QMA601 covers 0.1 to 2000 ppmV.

When selecting QMA601-LR, state the gas composition, operating pressure range, area classification, power supply and output requirements, and whether a sampling system is needed. Process analyzers are built to configuration, so we match your request to the manufacturer order-code sheet and confirm each option before quotation.

Installation and commissioning of QMA601-LR

As with the standard QMA601, the analyzer-only unit includes a desiccant dryer, back pressure regulator and gauge, and a sampling system is a separate code.

Install the analyzer close to the sample point where practical, supply it with a conditioned, representative sample at the pressure and flow stated in the manufacturer documentation, and make cable and gas entries with fittings that match the hazardous-area certificate. Follow the manual for electrical connections, vent routing and the first power-up sequence, and have a competent person verify the installation against the local area-classification drawings before energising.

Maintenance, calibration and service

Spares listed for the low-range model include QMA601-SHMI display assembly, QMA601-SDA dryer assembly, QMA-SMG-0.5P low-range moisture generator, QMA601-SFK filter kit and QMA-THERMAL-FUSE.

Routine care is mainly calibration verification, sample conditioning upkeep and replacement of consumable or wear items. Keep a record of calibration checks, alarms and any service performed, use the manufacturer recommended intervals as a starting point, and adjust them to your process experience and your site integrity procedures.

Related products and ordering notes for QMA601-LR

  • QMA601: standard range analyzer.
  • QMA-SMG-5P: medium range moisture generator for the QMA601.
  • PT-MON: Promet EExd moisture analyzer.

When you request QMA601-LR, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.

Frequently asked questions about QMA601-LR

  • What is QMA601-LR? QMA601-LR is the manufacturer parent code for the low-range QMA601 quartz crystal microbalance moisture analyzer, with a range of 0.02 to 100 ppmV.
  • What does QMA601-LR suit? It suits very low moisture measurement in natural gas, LNG and NGL streams in classified areas.
  • How does QMA601-LR differ from QMA601? The low-range version measures from 0.02 to 100 ppmV with accuracy of plus or minus 0.03 ppmV, while the standard version measures from 0.1 to 2000 ppmV.
  • What should I send with an RFQ for QMA601-LR? Send the part number QMA601-LR, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.

Documents and quotation

A manufacturer document is available for the product family of QMA601-LR and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number QMA601-LR, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for QMA601-LR in writing.

Other Models in the Michell Qma601 Range

Seven Star LLC supplies models from the Michell Qma601 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Michell QMA601 Quartz Crystal Microbalance Moisture AnalyzerGas Analyzer SystemsView details
Michell QMA601-LR Low-Range Moisture Analyzer 0.02 to 100 ppmVGas Analyzer SystemsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Michell QMA601-LR Low-Range Moisture Analyzer 0.02 to 100 ppmV Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the Michell QMA601-LR Low-Range Moisture Analyzer 0.02

Answers from our engineering team on installation, compatibility and integration.

01What is QMA601-LR?
QMA601-LR is the manufacturer parent code for the low-range QMA601 quartz crystal microbalance moisture analyzer, with a range of 0.02 to 100 ppmV.
02What does QMA601-LR suit?
It suits very low moisture measurement in natural gas, LNG and NGL streams in classified areas.
03How does QMA601-LR differ from QMA601?
The low-range version measures from 0.02 to 100 ppmV with accuracy of plus or minus 0.03 ppmV, while the standard version measures from 0.1 to 2000 ppmV.
04Can Seven Star LLC supply QMA601-LR in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for QMA601-LR?
Send the part number QMA601-LR, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.