Michell CD2-MON Condumax II Hydrocarbon Dew-Point Analyzer

Description

Michell CD2-MON overview: automatic hydrocarbon dew-point analyzer for natural gas

Michell CD2-MON is the parent order code of the Michell Condumax II analyzer-only unit. The order-code sheet describes it as an EExd certified, automatic, online hydrocarbon and water dew-point in natural gas analyser, using the fundamental chilled mirror principle with 0.5 degree Celsius hydrocarbon dew-point accuracy.

The analyzer has mains power, a capacitive touch screen, an integrated pressure reading, flow alarms, Modbus RTU and two 4-20 mA outputs, with an operating pressure of 15 to 100 barg and a flow of 0.06 cubic metres per hour.

The datasheet explains that the patented Dark Spot detection technique senses hydrocarbon condensate directly, which makes the measurement objective and repeatable for custody transfer gas quality.

The image shows the Condumax II analyzer from the manufacturer datasheet.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Michell CD2-MON so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.

Key features of CD2-MON

  • Fully automatic online analysis with a three-stage Peltier cooler and a depression of up to 55 K below the main unit temperature.
  • Hydrocarbon dew-point accuracy of plus or minus 0.5 degrees Celsius; optional water dew-point measurement using the Michell ceramic metal-oxide sensor.
  • Self-cleaning operation with no purge or cooling gas needed, suitable for natural gas with up to 20 percent hydrogen.
  • Six measurement cycles per hour recommended, up to twelve maximum.
  • Hazardous-area certification listed: ATEX and UKCA II 2 G Ex db IIB+H2 T3 Gb, IECEx, cQPSus and other national approvals.
  • Modbus RTU and two 4-20 mA outputs, with an analyzer fault flag at 23 mA on output 1.

CD2-MON technical specifications

The table below lists values published by the manufacturer for the product family of CD2-MON. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.

Parameter Value
Order code (parent) CD2-MON, Condumax II analyzer only
Technique Chilled mirror with Dark Spot detection
Accuracy Plus or minus 0.5 degC hydrocarbon dew point
Operating pressure 15 to 100 barg (analyzer for HC dew point)
Sample flow 0.03 m3/hr (0.5 Nl/min) alarm standard; order code states 0.06 m3/h
Measurement frequency 6 cycles per hour recommended; 12 maximum
Water dew-point range (optional) Calibrated minus 100 to plus 20 degC
Water dew-point accuracy Plus or minus 1 degC (minus 59 to plus 20 degC)
Pressure measurement HC dew point 0 to 100 barg; water dew point 0 to 200 barg; accuracy plus or minus 0.25 percent FS
Enclosure EExd cast enclosure with glass window, internally heated
Certification (ATEX/UKCA) II 2 G Ex db IIB+H2 T3 Gb, Tamb minus 40 to plus 60 degC
Communications Modbus RTU; two 4-20 mA outputs

Typical applications of CD2-MON in Oman and the GCC

  • Natural gas processing and protection of turbo-expander plant.
  • Gas quality measurement at custody transfer points.
  • Transmission pipeline monitoring.
  • Confirmation of fuel gas superheat to turbine power plants.

For operators in Oman and the GCC, process analyzers of this type are used where quality, safety or custody transfer depends on a defined gas composition: natural gas conditioning and export, glycol and molecular sieve dehydration units, LNG trains, refinery recycle gas, hydrogen and inert gas systems, and power generation fuel gas. Remote sites with high ambient temperatures need analyzers that are properly housed, certified for the area class, and supported with spares, which is why exact part numbers such as CD2-MON matter.

Selection and compatibility notes

The CD2-MON order string selects the analyzer type (hydrocarbon dew point only, or hydrocarbon and water dew point calculated using IGT 8 or ISO 18453) and the hazardous configuration (ATEX/IECEx or North American). Material certificates CD2-MON-M1 and CD2-MON-M2 are separate lines.

A version supplied with sampling system uses a different parent code.

When selecting CD2-MON, state the gas composition, operating pressure range, area classification, power supply and output requirements, and whether a sampling system is needed. Process analyzers are built to configuration, so we match your request to the manufacturer order-code sheet and confirm each option before quotation.

Installation and commissioning of CD2-MON

The analyzer should receive a conditioned natural gas sample at the stated flow, and the datasheet notes pressure regulation in the sampling system. Use certified glands and follow the manual for mirror cleaning access.

Install the analyzer close to the sample point where practical, supply it with a conditioned, representative sample at the pressure and flow stated in the manufacturer documentation, and make cable and gas entries with fittings that match the hazardous-area certificate. Follow the manual for electrical connections, vent routing and the first power-up sequence, and have a competent person verify the installation against the local area-classification drawings before energising.

Maintenance, calibration and service

The manufacturer lists CD2-SCR-002 hydrocarbon dew-point sensor cell assembly, CD2-WDC-002 water dew-point sensor assembly, CD2-SX-WDC-002 sensor exchange and CD2-SFK filter kit as spares.

Routine care is mainly calibration verification, sample conditioning upkeep and replacement of consumable or wear items. Keep a record of calibration checks, alarms and any service performed, use the manufacturer recommended intervals as a starting point, and adjust them to your process experience and your site integrity procedures.

Related products and ordering notes for CD2-MON

  • CD2-SCR-002: HC dew-point sensor cell assembly.
  • CD2-WDC-002: water dew-point sensor assembly.
  • PT-MON: Promet EExd moisture analyzer.

When you request CD2-MON, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.

Frequently asked questions about CD2-MON

  • What is CD2-MON? CD2-MON is the manufacturer parent code for the Condumax II analyzer, an EExd automatic hydrocarbon and optional water dew-point analyzer for natural gas.
  • What does CD2-MON suit? It suits hydrocarbon dew-point measurement in natural gas processing, custody transfer and pipeline monitoring in classified areas.
  • What accuracy does CD2-MON provide? The datasheet gives plus or minus 0.5 degrees Celsius for hydrocarbon dew point, and plus or minus 1 degree Celsius for the optional water dew-point from minus 59 to plus 20 degrees Celsius.
  • What should I send with an RFQ for CD2-MON? Send the part number CD2-MON, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.

Documents and quotation

A manufacturer document is available for the product family of CD2-MON and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number CD2-MON, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for CD2-MON in writing.

Datasheets & Documents
  • PDF Datasheet Michell CD2-MON Condumax II Hydrocarbon Dew-Point Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the Michell CD2-MON Condumax II Hydrocarbon Dew-Point

Answers from our engineering team on installation, compatibility and integration.

01What is CD2-MON?
CD2-MON is the manufacturer parent code for the Condumax II analyzer, an EExd automatic hydrocarbon and optional water dew-point analyzer for natural gas.
02What does CD2-MON suit?
It suits hydrocarbon dew-point measurement in natural gas processing, custody transfer and pipeline monitoring in classified areas.
03What accuracy does CD2-MON provide?
The datasheet gives plus or minus 0.5 degrees Celsius for hydrocarbon dew point, and plus or minus 1 degree Celsius for the optional water dew-point from minus 59 to plus 20 degrees Celsius.
04Can Seven Star LLC supply CD2-MON in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for CD2-MON?
Send the part number CD2-MON, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.