Michell QMA601 Quartz Crystal Microbalance Moisture Analyzer
Description
Michell QMA601 overview: Exd trace moisture analyzer with quartz crystal microbalance
Michell QMA601 is the parent order code of the Michell QMA601 process moisture analyzer, an Exd-certified, automatic online quartz crystal microbalance instrument. The datasheet gives a measurement range of 0.1 to 2000 ppmV, with accuracy of plus or minus 0.1 ppmV below 1 ppmV and 10 percent of reading from 1 to 2000 ppmV.
It has a seven-inch colour touch screen, RS485 Modbus RTU and Modbus TCP, two 4-20 mA outputs and four volt-free contact outputs, with an internal moisture generator that is traceable to NPL and NIST. The manufacturer states that it is maintenance free for three years.
It is used for glycol and molecular sieve dehydration of natural gas, refinery catalytic reforming recycle gas, ethylene and propylene production and LNG.
The image shows the QMA601 analyzer in a sampling system from the manufacturer datasheet.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list QMA601 so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of QMA601
- Fast response quartz crystal microbalance: T63 under 2 minutes and T95 under 5 minutes for the standard variant.
- Built-in automatic calibration using an internal moisture generator traceable to NPL and NIST.
- Units selectable: ppmV, ppmW, mg per normal cubic metre, vapour pressure, dew point and lb per MMscf.
- Flameproof GUB enclosure in cast copper-free aluminium with explosion-proof glass window, IP66 and NEMA 4.
- Alarms: one system alarm and three process alarms as volt-free change-over contacts.
- Certifications listed: ATEX and UKCA II 2 GD Ex db IIB+H2 T6 Gb, IECEx, cQPSus and TR CU Ex.
QMA601 technical specifications
The table below lists values published by the manufacturer for the product family of QMA601. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.
| Parameter | Value |
|---|---|
| Order code (parent) | QMA601, QMA601 analyzer |
| Technology | Fast response quartz crystal microbalance |
| Calibrated range | 0.1 to 700 ppmV |
| Measurement range | 0.1 to 2000 ppmV |
| Accuracy | Plus or minus 10 percent of reading (1 to 2000 ppmV); plus or minus 0.1 ppmV (0.1 to 1 ppmV) |
| Limit of detection | 0.1 ppmV |
| Response | T63 under 2 min; T95 under 5 min (standard 30-30 second cycle) |
| Supply | 85 to 264 V AC or 24 V DC (ATEX/IECEx/UKCA); 24 V DC only (cQPSus) |
| Outputs | Two 4-20 mA or 1-5 V; RS485 Modbus RTU; Modbus TCP |
| Inlet and outlet pressure | 2 barg inlet; 1 barg outlet |
| Sample flow | 300 ml/min total flow |
| Gas connections | 1/8 inch NPT |
| Weight | 35 kg without sampling system |
| Local interface | 7 inch colour LCD with touch HMI |
Typical applications of QMA601 in Oman and the GCC
- Glycol dehydration of natural gas.
- Molecular sieve dehydration of natural gas.
- Natural gas transmission and storage.
- Refinery catalytic reforming recycle gas.
- Ethylene and propylene production and LNG revaporisation.
For operators in Oman and the GCC, process analyzers of this type are used where quality, safety or custody transfer depends on a defined gas composition: natural gas conditioning and export, glycol and molecular sieve dehydration units, LNG trains, refinery recycle gas, hydrogen and inert gas systems, and power generation fuel gas. Remote sites with high ambient temperatures need analyzers that are properly housed, certified for the area class, and supported with spares, which is why exact part numbers such as QMA601 matter.
Selection and compatibility notes
The QMA601 order string selects hazardous configuration (ATEX/IECEx, or cQPSus at 24 V DC), moisture generator range (low about 0.5 ppmV, medium about 5 ppmV, high about 50 ppmV) and calibration (standard 0.1 to 700 ppmV, asymmetric, or CO2 calibration 1 to 1000 ppmV). Material certificates QMA601-M1 and M2 are ordered separately.
For very low moisture, the QMA601-LR extends the range down to 0.02 ppmV.
When selecting QMA601, state the gas composition, operating pressure range, area classification, power supply and output requirements, and whether a sampling system is needed. Process analyzers are built to configuration, so we match your request to the manufacturer order-code sheet and confirm each option before quotation.
Installation and commissioning of QMA601
The analyzer-only unit is supplied with a desiccant dryer, back pressure regulator and gauge. Sampling systems QMA601-SYS-I and QMA601-SYS-M are separate codes with options for fast loop bypass.
Install the analyzer close to the sample point where practical, supply it with a conditioned, representative sample at the pressure and flow stated in the manufacturer documentation, and make cable and gas entries with fittings that match the hazardous-area certificate. Follow the manual for electrical connections, vent routing and the first power-up sequence, and have a competent person verify the installation against the local area-classification drawings before energising.
Maintenance, calibration and service
The manufacturer lists spares including QMA601-SHMI display assembly, QMA601-SDA dryer assembly, QMA601-SCT contamination trap, QMA-SMG moisture generators, QMA601-SFK filter kit and QMA-THERMAL-FUSE.
Routine care is mainly calibration verification, sample conditioning upkeep and replacement of consumable or wear items. Keep a record of calibration checks, alarms and any service performed, use the manufacturer recommended intervals as a starting point, and adjust them to your process experience and your site integrity procedures.
Related products and ordering notes for QMA601
- QMA601-LR: low-range version down to 0.02 ppmV.
- QMA-SMG-5P: replacement medium range moisture generator.
- PT-MON: Promet EExd moisture analyzer.
When you request QMA601, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.
Frequently asked questions about QMA601
- What is QMA601? QMA601 is the manufacturer parent code for the QMA601 process moisture analyzer, an Exd-certified quartz crystal microbalance analyzer for trace moisture in gases.
- What does QMA601 suit? It suits trace moisture monitoring at 0.1 to 2000 ppmV in natural gas dehydration, LNG, refinery and petrochemical gas streams in classified areas.
- How does QMA601 stay calibrated? It has an internal moisture generator that is traceable to NPL and NIST, which allows automatic calibration and verification of the process gas.
- What should I send with an RFQ for QMA601? Send the part number QMA601, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.
Documents and quotation
A manufacturer document is available for the product family of QMA601 and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number QMA601, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for QMA601 in writing.
Other Models in the Michell Qma601 Range
Seven Star LLC supplies models from the Michell Qma601 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Michell QMA601 Quartz Crystal Microbalance Moisture Analyzer | Gas Analyzer Systems | You are viewing this model |
| Michell QMA601-LR Low-Range Moisture Analyzer 0.02 to 100 ppmV | Gas Analyzer Systems | View details |
Datasheets & Documents
- Datasheet Michell QMA601 Quartz Crystal Microbalance Moisture Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell QMA601 Quartz Crystal Microbalance Moisture
Answers from our engineering team on installation, compatibility and integration.
01What is QMA601?
QMA601 is the manufacturer parent code for the QMA601 process moisture analyzer, an Exd-certified quartz crystal microbalance analyzer for trace moisture in gases.
02What does QMA601 suit?
It suits trace moisture monitoring at 0.1 to 2000 ppmV in natural gas dehydration, LNG, refinery and petrochemical gas streams in classified areas.
03How does QMA601 stay calibrated?
It has an internal moisture generator that is traceable to NPL and NIST, which allows automatic calibration and verification of the process gas.
04Can Seven Star LLC supply QMA601 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for QMA601?
Send the part number QMA601, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.


















Reviews