Lovato BF1801A230 Contactor 18 A AC-3, 230 V AC Coil
Description
Lovato BF1801A230 three-pole contactor, 18 A AC-3, 230 V coil
The Lovato BF1801A230 is a three-pole contactor from the BF18 frame, rated 18 A in AC-3 and 32 A thermal. It switches motors of about 7.5 kW at 400 V and is controlled by a 230 V AC coil. Seven Star LLC supplies the BF1801A230 in Oman and the GCC as an independent supplier in Muscat.
The code breaks down as BF18 for the frame and the 18 A rating, 01 for the integral auxiliary contact version, A for AC coil and 230 for volts. The BF1810A230 sibling in our range shares frame and coil but has the alternative auxiliary arrangement. The BF18 frame is where contactors start to need real attention to heat and to short-circuit protection, so the ratings below deserve a careful read.
BF1801A230 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Lovato / BF1801A230 |
| Poles | 3 |
| Ith at 40 °C | 32 A |
| AC-1 at 40 / 55 / 70 °C | 32 / 26 / 23 A |
| AC-3 operational current | 18 A |
| AC-4 at 400 V | 8.5 A |
| AC-3 power at 230 / 400 / 500 / 690 V | 4 / 7.5 / 10 / 10 kW |
| AC-1 power at 400 V | 21 kW |
| Back-up fuses | 32 A gG; 20 A aM |
| Making capacity / breaking at 440 V | 180 A / 144 A |
| Short-time current, 10 s | 200 A |
| Coil | 230 V AC; 75 VA inrush and 9 VA holding at 50 Hz |
| Power dissipation per pole | 1.5 W at Ith; 0.5 W at AC-3 |
| Life | 20 million mechanical; 1.6 million electrical at AC-3 400 V |
| Auxiliary contact | Ith 10 A; AC-15 3 A at 230 V |
| Weight | 358 g |
The BF1801A230 at AC-3 and AC-1
AC-3 describes squirrel-cage motor starting and stopping while running, which is the main use. At 400 V the 18 A rating gives 7.5 kW. For resistive loads such as heaters, the AC-1 current of 32 A at 40 °C gives 21 kW at 400 V, but the value drops to 26 A at 55 °C and 23 A at 70 °C, so heater stages in hot panels must be sized from the lower figures.
The electrical life of 1.6 million operations at AC-3 400 V is shorter than the 2 million of the smaller BF09, which reflects the heavier current. Frequent starting, jogging or plugging reduces life further, so applications with heavy duty should use a larger frame.
BF1801A230 in a combination starter
Combine the contactor with a motor protection breaker like the SM1P1800 (13 to 18 A) for a coordinated starter. The data sheet recommends 32 A gG or 20 A aM fuses for short-circuit protection. With an 18 A thermal overload relay or an electronic motor relay, a full direct-on-line starter results. The contactor also forms the main element of reversing and star-delta starters when paired with a second or third unit.
BF1801A230 selection checklist
- Motor current of 18 A or less at AC-3 and starting duty
- 230 V AC coil and available control supply
- Auxiliary contact arrangement needed
- Panel ambient temperature and AC-1 derating
- Fuse or breaker protection within the listed values
- Operating frequency and electrical life target
- Terminal wire size, up to 6 mm² flexible
Installing and maintaining the BF1801A230
Mount on rail or by screws with at least the clearances shown in the instruction sheet; terminals take 1.5 to 1.8 Nm and the coil terminals 0.8 to 1 Nm. A contactor operating near its limit runs warm, so avoid stacking units without space.
Inspect for discolouration, check coil voltage under starting conditions and replace the unit when switching becomes noisy. If the coil is driven by an electronic output, add suppression to protect the output stage.
Typical BF1801A230 applications in Oman and the GCC
The 18 A contactor appears on water transfer pumps, ventilation fans, small compressors and conveyors. In coastal sites, humidity and salt in the air make an enclosure with good sealing and anti-condensation heating wise, since corrosion attacks terminals first.
BF18 contactors in this range
| Part | AC-3 current | Coil | Note |
|---|---|---|---|
| BF0901A230 | 9 A | 230 V AC | Smaller frame |
| BF1801A230 | 18 A | 230 V AC | This part |
| BF1810A230 | 18 A | 230 V AC | Alternative auxiliary arrangement |
| BF2510A230 | 25 A | 230 V AC | Larger frame |
When the motor current is close to 18 A, consider the start-up current and the time spent starting. A pump with a long run-up on a weak supply may heat the contacts more than the AC-3 rating suggests, and a larger frame such as the BF2510A230 gives more headroom. For loads that start rarely and run for long periods, the BF18 is an economical choice. Review the cable cross-section too: at 18 A a 4 mm² conductor is commonly used, which sits inside the terminal capacity, but long runs in hot trays may need the next size up to keep voltage drop low and avoid heating at the lugs.
Information to send with an RFQ for the BF1801A230
- Part number BF1801A230 and quantity
- Motor data and duty
- Control voltage
- Auxiliary contact needs
- Temperature in the panel
- Delivery location
Site conditions in Oman for the BF1801A230
Low-voltage switching and protection devices in Oman often sit in motor control centres and outdoor panels where internal temperatures are high for much of the year. When you select the BF1801A230, check its rated values at your real ambient temperature, as stated in the manufacturer documentation, and confirm the coordination with upstream protection and with the motor or load it serves. Short-circuit levels differ from site to site, so verify the breaking capacity required at the point of installation.
Standardising ratings and coil voltages across a project reduces the number of spare part numbers that need to be stocked. Keeping a small stock of the BF1801A230 and recording settings such as trip ranges or ramp times shortens repair work during a breakdown.
Documents and quotation
Send the part number BF1801A230 and we will confirm the documents available for it, such as the technical data sheet, wiring diagram and instruction sheet, together with availability and lead time.
Seven Star LLC is an independent supplier in Muscat and is not an official channel of the manufacturer. Share the quantity, delivery location and project reference with the request and we will answer with a formal quotation.
Other Models in the Lovato Bf Contactor Range
Seven Star LLC supplies models from the Lovato Bf Contactor range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Lovato BF0901A230 Contactor 9 A AC-3, 230 V AC Coil | Contactors & Overload Relays | View details |
| Lovato BF1801A230 Contactor 18 A AC-3, 230 V AC Coil | Contactors & Overload Relays | You are viewing this model |
Reviews (0)
How would you rate this product? Cancel reply
About brand
Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.
Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.
Lovato Electric at a glance
| Established | 1922, Bergamo, Italy |
|---|---|
| Headquarters | Gorle (Bergamo), Italy |
| Ownership | Private, family-run for four generations |
| Product families | Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs |
Lovato products we list
| Family | Models | Typical use |
|---|---|---|
| Contactors | BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing | Switching motors, heaters, lighting and capacitor banks |
| Motor protection and starters | SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay | Short-circuit and overload protection and direct starting of motors |
| Soft starters | ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 | Reducing starting current and mechanical shock on pumps, fans and compressors |
| Variable speed drives | VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 | Speed control of pumps, fans and conveyors to save energy |
| Power management and control | DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC | Power factor correction, mains/generator changeover and energy monitoring |
Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.
Where Lovato products are used
In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.
Ordering Lovato products: what we need
Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.
Facts checked against Lovato Electric company profile brochures, October 2026.
Browse Lovato Electric products by category: Motor Soft Starters, Automation Accessories, Controllers & Data Acquisition, PLC & I/O Cards, Circuit Breakers, Diesel Generator Spare Parts.
FAQ
Questions about the Lovato BF1801A230 Contactor 18 A AC-3, 230 V AC Coil
Answers from our engineering team on installation, compatibility and integration.
01What is the AC-3 rating of the BF1801A230?
It is 18 A, which gives 7.5 kW at 400 V and 4 kW at 230 V.
02What is the thermal current?
The conventional free-air thermal current Ith is 32 A at 40 degrees C.
03What fuses are recommended?
The catalogue lists 32 A gG and 20 A aM back-up fuses.
04How many operations can it perform?
The mechanical life is 20 million operations and the electrical life is 1.6 million at AC-3, 400 V.
05What coil is fitted?
A 230 V AC coil with 75 VA inrush and 9 VA holding power at 50 Hz.