Lovato ATL500 Automatic Transfer Switch Controller
Description
Changeover logic for mains and generator panels
The ATL500 is an automatic transfer switch controller from Lovato Electric for 2 power sources. The catalogue entry reads: Automatic transfer switch controller for 2 power sources, self-powered, three phase control, with NFC and synoptic. It monitors the voltage and frequency of the supplies, decides when to change over and drives the switching devices through relay outputs.
Input rating 415VAC L-L (240VAC L-N), supply 110-240 VAC, true RMS measurement. The front shows no.
Technical specifications
| Parameter | Specification |
|---|---|
| Order code | ATL500 |
| Product designation | Automatic transfer switch controller for 2 power sources, self-powered, three phase control, with NFC and synoptic |
| Product type designation | ATL500 |
| Number of controlled power sources | 2 |
| Display | No |
| Expandability | No |
| Rated supply voltage AC | 110-240 VAC |
| Operating supply voltage range AC | 90-300VAC L-N |
| Rated frequency | 50/60 Hz |
| Operating frequency range | 45-66 Hz |
| Immunity time for microbreakings, 110VAC | ≤200 ms |
| Immunity time for microbreakings, 220VAC | ≤400 ms |
| Power consumption AC (Max) | 3.7 VA |
| Maximum rated voltage Ue | 415VAC L-L (240VAC L-N) |
| Measurement range | 155-519VAC L-L (90-300VAC L-N) |
| Frequency range | 45-66 Hz |
| Measurement method | True root mean square (TRMS) |
| phase-phase | above 1.0MΩ |
| phase-neutral | above 0.5MΩ |
| Measuring accurancy | ±0.25% f.s. |
| Wiring mode | Single-phase, two-phase, three-phase with neutral system |
| Number of digital input | 2 |
| Type of digital input | Negative |
| Digital current inputs | ≤5mA |
| Low input signal | ≤2.6V VDC |
| High input signal | ≥3.1V VDC |
| Input signal delay | ≥50 ms |
| Number of relay output | 3 |
| Contact arrangement | 2 x 1NO-SPST (OUT1, OUT2) + 1 x C/O-SPDT (OUT3) |
| Electrical life | 10⁵ cycles |
| Mechanical life | 10⁷ cycles |
| NFC interf. | Yes |
| Programmable source type | Single-phase, two-phase, three-phase with neutral |
| Operating temperature (min) | -30 °C |
| Operating temperature (max) | +70 °C |
| Storage temperature (min) | -30 °C |
| Storage temperature (max) | +80 °C |
| Maximum Pollution degree | 2 |
| Overvoltage category | 3 |
| Climatic sequence | Z/ABDM (IEC/EN 60068-2-61) |
| Shock resistance | 15g (IEC/EN 60068-2-27) |
| Vibration resistance | 0.7g (IEC/EN 60068-2-6) |
| Execution | Flush mount |
| Material | Polycarbonate |
| Mounting | Flush mount – panel cut-out 138×138 mm |
| Degree of protection | IP40 on front, IP65 with optional gasket code EXP8001, IP20 on terminals |
| Dimensions (W x H x D) | 144 x 144 x 52.2mm |
| Weight | 580 g |
Selecting the version
The ATL family splits as follows: ATL100 for single-phase two-source panels, ATL500 and ATL600 for three-phase two-source panels, ATL800 for two sources plus a tie-breaker and ATL900 for three sources with two tie-breakers. Pick the one that matches the single-line diagram.
Check the voltage range and the number of relay outputs against the contactor or breaker coils and the generator start signal.
Applications and installation
Typical use is a mains and generator changeover panel for pumping stations, telecom sites, data rooms and building services. The controller is panel-mounted or DIN-rail mounted depending on version.
Dimensions are listed in the table. Relay outputs and inputs are programmable; use the Xpress software or the optical interface to configure.
For panel design and commissioning, the practical figures to keep at hand are: measuring accurancy ±0.25% f.s.; wiring mode Single-phase, two-phase, three-phase with neutral system; climatic sequence Z/ABDM (IEC/EN 60068-2-61); shock resistance 15g (IEC/EN 60068-2-27); vibration resistance 0.7g (IEC/EN 60068-2-6); execution Flush mount; material Polycarbonate; mounting Flush mount – panel cut-out 138×138 mm; degree of protection IP40 on front, IP65 with optional gasket code EXP8001, IP20 on terminals; dimensions (W x H x D) 144 x 144 x 52.2mm; weight 580 g; operating temperature (min) -30 °C; operating temperature (max) +70 °C; number of relay output 3. These come straight from the datasheet and are repeated here so that the key installation limits are visible without opening the PDF.
Related Lovato Electric products: Lovato ATL600 Automatic Transfer Switch Controller 2 Sources, Lovato DCRL8 8-Step Automatic Power Factor Controller, Lovato LVM20A240 LVM20 Level Control Relay, Lovato LVM40A240 LVM40 Level Control Relay, Lovato PMIB1A230 Insulation Monitoring Relay for IT Networks and Lovato LVMP30A240 LVMP30 Pump Start-Up Priority Change Relay.
Documents and quotation
Attached is the English datasheet that Lovato Electric’s online catalogue generates for ATL500; the specification table above reproduces its values. Make sure of the number of sources, the supply voltages, the contactor or breaker type and the generator start arrangement before placing an order, since the published values can change. More products of this type are under controllers & data acquisition. Use the quotation form with the code ATL500 and your quantity; availability is confirmed by Seven Star LLC, an independent supplier in Muscat.
Datasheets & Documents
- Datasheet Lovato Electric ATL500 datasheet (EN, catalogue export) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.
Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.
Lovato Electric at a glance
| Established | 1922, Bergamo, Italy |
|---|---|
| Headquarters | Gorle (Bergamo), Italy |
| Ownership | Private, family-run for four generations |
| Product families | Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs |
Lovato products we list
| Family | Models | Typical use |
|---|---|---|
| Contactors | BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing | Switching motors, heaters, lighting and capacitor banks |
| Motor protection and starters | SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay | Short-circuit and overload protection and direct starting of motors |
| Soft starters | ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 | Reducing starting current and mechanical shock on pumps, fans and compressors |
| Variable speed drives | VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 | Speed control of pumps, fans and conveyors to save energy |
| Power management and control | DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC | Power factor correction, mains/generator changeover and energy monitoring |
Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.
Where Lovato products are used
In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.
Ordering Lovato products: what we need
Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.
Facts checked against Lovato Electric company profile brochures, October 2026.
Browse Lovato Electric products by category: Motor Soft Starters, Automation Accessories, Controllers & Data Acquisition, PLC & I/O Cards, Circuit Breakers, Diesel Generator Spare Parts.
FAQ
Questions about the Lovato ATL500 Automatic Transfer Switch Controller
Answers from our engineering team on installation, compatibility and integration.
01How many power sources does the ATL500 control?
2.
02What display does it have?
No.
03What supply range does it accept?
110-240 VAC.
04How many relay outputs does it have?
3.
05What is the weight of the ATL500?
580 g.