Brand:

ION Science MiniPID 2 PPM Fast-Response PID Gas Sensor

Description

Overview

The ION Science MiniPID 2 PPM is the ppm-level PID in the MiniPID 2 family, optimised for survey, leak detection and process work rather than for trace ambient air. According to the datasheet it has a minimum detection limit of 100 ppb, a range above 4,000 ppm and a T90 response time of less than 3 seconds, the fastest of any sensor in the series. Seven Star LLC is an independent supplier serving Oman and the GCC. The following notes are an engineering reading of the manufacturer’s data.

A fast sensor for leak hunting

When an operator walks a pipe rack with a handheld, every second of delay moves the apparent position of a leak by a metre or more. A T90 below 3 seconds means that the reading follows the probe tip closely, and a leak can be pinpointed by sweeping the area and watching the signal rise. Sensitivity is more than 0.65 mV per ppm at 100 ppm, lower than the PPB sensors, and that is deliberate: a lower sensitivity keeps the electronics out of saturation at thousands of ppm. The electrode stack is blue, which is the colour used for the PPM line.

Performance data for ION Science MiniPID 2 PPM

Item Value
Electrode stack colour blue
Minimum detection limit 100 ppb
Range more than 4,000 ppm
T90 response time less than 3 seconds
Sensitivity more than 0.65 mV/ppm at 100 ppm
Lamp-out diagnostic yes
Lamp 10.6 eV
Supply voltage, internal regulator 3.6 to 18 V (10 to 18 V when not intrinsically safe)
Supply voltage, regulated supply 3 to 3.6 V
Current 20 to 32 mA, 130 mA for 100 ms at start-up
Power consumption 100 mW at 3.2 V
Output signal 0 to rail voltage minus 0.1 V
Temperature range minus 40 to plus 65 degrees C
Humidity range 0 to 99 percent RH, non-condensing
Sensor body life more than 5 years
Lamp life 10,000 hours
Package Series 4/A
Order codes MP3SMLLAU2 (3.0 to 3.2 V), MP3SMLLBU2 (3.2 to 3.6 V), MP3SMLLCU2 (3.6 to 10.0 V), MP3SMLLNU2 (3.6 to 18 V)
Hazardous area approvals ATEX II 1G Ex ia IIC Ga and IECEx Ex ia IIC Ga, minus 40 to plus 55 degrees C ambient at 1.1 W; UL913 Class I, II, III Division 1; EAC

Applications for the ION Science MiniPID 2 PPM

  • Industrial health and safety and confined space entry
  • Leak detection and repair
  • Survey work and process control
  • Soil contamination and remediation
  • LEL measurement, where the sensor provides an early indication of vapour well below the explosive limit

Oil and gas facilities in Oman use such instruments around pumps, flanges, valves, tank vents and sample stations. For vapour from gasoline, naphtha, solvents and aromatics, PID gives a far earlier warning than a catalytic bead sensor, since it responds in ppm rather than percent of the lower explosive limit.

How MiniPID 2 PPM differs from the PPM WR and PPB sensors

The nearest sibling is the PPM WR, whose detection limit is 500 ppb and whose range is above 10,000 ppm with sensitivity above 0.4 mV per ppm; choose it if concentrations may exceed 4,000 ppm. The PPB line, with limits from 1 to 20 ppb and ranges from 40 to 200 ppm, is for trace work and becomes saturated in a leak survey. The PPM sits between them, covering 100 ppb to above 4,000 ppm, and its T90 under 3 seconds is much quicker than the 8 to 12 seconds of the PPB family.

Electrical and approval data

The sensor runs from 3.6 to 18 V through the internal regulator, or 3 to 3.6 V from a regulated supply; non-intrinsically safe use needs 10 to 18 V. Current is 20 to 32 mA with a start-up surge of 130 mA for 100 ms, and power consumption is 100 mW at 3.2 V, slightly different from the 3.3 V stated for other models. The output reaches the rail minus 0.1 V. Operating range is minus 40 to plus 65 degrees C and 0 to 99 percent RH without condensation. Approvals are ATEX II 1G Ex ia IIC Ga, IECEx, UL913 Class I, II, III Division 1 and Eurasian customs certification. Lamp life is 10,000 hours and body life more than five years.

Calibration for survey instruments

Use isobutylene as the reference gas and set span near the concentration of interest, perhaps 100 or 500 ppm, then apply the response factor of the vapour under investigation. Note that humidity and temperature affect PID readings slightly; the sensor is rated humidity resistant, but calibration in conditions similar to the field gives the best result. The lamp-out diagnostic lets the host instrument warn the user when the lamp fails, which is critical for safety because a dead lamp would give a false clear reading.

Choosing a sampling arrangement

A survey instrument usually draws gas past the sensor with a small pump through a probe and a particulate filter, while a fixed monitor may let gas diffuse in naturally. Impressed flow gives the quickest and most repeatable response; diffusion is simpler and quieter but slower and affected by air movement. The datasheet notes that the ION CONNECT kit is optimised for both methods. Whatever the choice, keep the tubing short, make it of a material that does not adsorb the target vapours, and avoid dead volumes, since sticky compounds such as heavy aromatics linger in long lines and slow the apparent response.

Service notes

Clean the electrode stack and lamp window when the baseline drifts or the sensitivity decreases, and replace the lamp at the end of its life. In dusty environments, add a particulate filter to the sampling inlet. Keep a record of each service so that you know when the next one is due.

System kits

ION CONNECT supports UART and I2C for rapid integration, with PC software for calibration, alarms and response factors, optimised for diffused and impressed flow sampling. The ION GAS HOOD supplies impressed flow, and ION TRANSMIT adds RS-485 Modbus RTU and 4 to 20 mA output.

Related items you may also need: ION Science Tiger XT Handheld VOC Detector | ION Science Titan 2 Fixed Benzene Monitor | MSA Senscient ELDS Open Path Laser Gas Detector | All ION Science products.

Points to confirm for the ION Science MiniPID 2 PPM

  • If the ION Science MiniPID 2 PPM is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
  • For each ION Science MiniPID 2 PPM request we confirm the exact code and lead time in writing.
  • Dimensions, ratings and connection data for the ION Science MiniPID 2 PPM are in the datasheet attached to this page.
  • The ION Science MiniPID 2 PPM belongs to our fire & gas detectors range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
  • Plants that run the ION Science MiniPID 2 PPM on critical service often hold a spare unit in the store.

Documents and quotation

The ION Science MiniPID 2 PPM datasheet from the manufacturer includes the full performance table and order codes. We include the sensor datasheet with this page; it shows the drawings and the order codes. Send your RFQ stating the model, the order code that matches your supply voltage, the quantity, and your delivery location in Oman or the GCC.

Other Models in the MiniPID2 Range

Seven Star LLC supplies models from the MiniPID2 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ION Science MiniPID 2 PPB VOC PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 PPB WR Wide-Range PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 PPB XF Long-Life PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 HS High-Sensitivity PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 10.0 eV BTEX Benzene PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 11.7 eV High-Energy PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 PPM Fast-Response PID Gas SensorFire & Gas DetectorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet ION Science MiniPID 2 PPM Fast-Response PID Gas Sensor Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ION Science is a British maker of gas detection instruments, based in Fowlmere, Cambridgeshire. It has been active since 1989 and is best known for photoionisation detectors (PIDs) that measure volatile organic compounds at low concentrations. Its portable and fixed instruments are used for worker exposure monitoring, leak detection and environmental surveys.

Seven Star LLC is an independent supplier in Muscat. We list ION Science detectors for oil and gas, petrochemical and environmental users in Oman and the GCC.

ION Science company profile

Active since 1989, United Kingdom
Head office Fowlmere, Cambridgeshire
Core technology Photoionisation detection (PID) with patented Fence Electrode design
Product families Tiger XT and Cub portable PIDs, Titan benzene monitor, Falco fixed detectors

Milestones

  • 1989: ION Science begins operating.
  • 1998: Patents its PID sensor.
  • 2002: Patents the Fence Electrode for humidity-resistant PIDs.
  • 2017: Opens its head office in Fowlmere.

ION Science product series

The Tiger XT is a handheld VOC detector for hazardous areas, and the Titan 2 is a fixed benzene monitor.

A PID uses ultraviolet light to ionise volatile organic compounds and measures the resulting current, which allows detection down to ppb levels. Response factors convert the reading for each specific compound. General VOC detectors measure the total, while benzene-specific monitors separate benzene from other hydrocarbons, which matters because benzene has very low exposure limits.

Where ION Science detectors are used

Leak detection, confined space entry checks, worker exposure monitoring, refinery and terminal benzene monitoring, and environmental and soil surveys.

Ordering ION Science detectors: what we need

Send the model, the compounds and ranges, lamp type, hazardous-area requirement and accessories such as probes, filters and calibration kits.

Facts checked against ION Science's published company history, October 2026.

FAQ

Questions about the ION Science MiniPID 2 PPM Fast-Response PID Gas

Answers from our engineering team on installation, compatibility and integration.

01What range does the ION Science MiniPID 2 PPM cover?
The datasheet gives a minimum detection limit of 100 ppb and a range above 4,000 ppm, with sensitivity above 0.65 mV per ppm at 100 ppm.
02How fast is the MiniPID 2 PPM?
T90 response time is less than 3 seconds, the quickest figure among the MiniPID 2 sensors in the datasheets, which suits leak detection.
03Which order codes does the MiniPID 2 PPM have?
MP3SMLLAU2 for 3.0 to 3.2 V, MP3SMLLBU2 for 3.2 to 3.6 V, MP3SMLLCU2 for 3.6 to 10.0 V and MP3SMLLNU2 for 3.6 to 18 V.
04When should I choose the PPM WR instead of the PPM?
Choose the PPM WR if concentrations may exceed 4,000 ppm, since it covers above 10,000 ppm, at the cost of a 500 ppb detection limit.
05Does the MiniPID 2 PPM have a lamp-out diagnostic?
Yes, lamp-out diagnostic is listed among its key features, with a lamp life of 10,000 hours and a serviceable electrode stack.