ION Science MiniPID 2 PPB WR Wide-Range PID Gas Sensor
Description
Overview
The ION Science MiniPID 2 PPB WR is the wide-range sibling in the PPB line of photoionisation sensors. ION SENSE calls it a simple plug-and-play sensor that gives a dynamic and dependable response to thousands of volatile organic compounds, and the datasheet puts numbers on that: a minimum detection limit of 20 ppb and a range above 200 ppm. Seven Star LLC is an independent supplier serving Oman and the GCC. It is a module for builders of gas monitors rather than a finished instrument.
Trading the last ppb for headroom
Every PID designer faces a choice between sensitivity at the bottom and capacity at the top. The PPB WR sits in the middle. Its sensitivity is above 5 mV per ppm, compared with more than 30 mV per ppm on the PPB, so each ppm of vapour moves the output less, and the sensor therefore stays linear and useful up to concentrations five times higher than the PPB can handle. Response is fast, with a T90 of less than 8 seconds. If the application is an outdoor or indoor air quality monitor that needs to flag a solvent spike from 20 ppb up to a few hundred ppm without changing sensor, this is the model the datasheet points to.
Technical data of ION Science MiniPID 2 PPB WR
| Item | Value |
|---|---|
| Electrode stack colour | white |
| Minimum detection limit | 20 ppb |
| Range | more than 200 ppm |
| T90 response time | less than 8 seconds |
| Sensitivity | more than 5 mV/ppm |
| Lamp | 10.6 eV |
| Supply voltage, internal regulator | 3.6 to 18 V (10 to 18 V when not intrinsically safe) |
| Supply voltage, regulated supply | 3 to 3.6 V |
| Current | 20 to 32 mA, 130 mA for 100 ms at start-up |
| Power consumption | 100 mW at 3.3 V |
| Output signal | 0 to rail voltage minus 0.1 V |
| Temperature range | minus 40 to plus 65 degrees C |
| Humidity range | 0 to 99 percent RH, non-condensing |
| Sensor body life | more than 5 years |
| Lamp life | 10,000 hours |
| Package | Series 4/A |
| Order codes | MP3SWBLBAU2 (3.0 to 3.2 V), MP3SWBLBBU2 (3.2 to 3.6 V), MP3SWBLBCU2 (3.6 to 10.0 V), MP3SWBLBNU2 (3.6 to 18 V) |
| Hazardous area approvals | ATEX II 1G Ex ia IIC Ga and IECEx Ex ia IIC Ga, minus 40 to plus 55 degrees C ambient at 1.1 W; UL913 Class I, II, III Division 1; EAC |
Typical uses of the ION Science MiniPID 2 PPB WR
- Outdoor and indoor air quality monitoring
- HVAC control and ventilation checks
- Industrial health and safety and confined space entry
- Arson investigation, where residual accelerant vapours must be found
- Leak detection
- Soil contamination and remediation
In Gulf cities and industrial zones, ambient VOC monitoring is gaining attention around refineries, ports, and dense traffic corridors. A sensor with a 200 ppm range copes with the occasional spike near a vent without saturating, while the 20 ppb limit still reports background levels.
How MiniPID 2 PPB WR differs from the PPB and PPM versions
Against the ION Science MiniPID 2 PPB WR family neighbours the arithmetic is simple. The PPB reads from 1 ppb but tops out above 40 ppm. The PPB WR reads from 20 ppb and tops out above 200 ppm. The PPM covers 100 ppb to above 4,000 ppm and responds in under 3 seconds, and the PPM WR covers 500 ppb to above 10,000 ppm with sensitivity above 0.4 mV per ppm. Pick by the highest concentration you must measure first, then check that the lowest alarm point sits comfortably above the detection limit.
Design-in notes
The package is the Series 4/A format, and the supply can be 3.6 to 18 V through the internal regulator, or 3 to 3.6 V from a regulated rail. Current draw is 20 to 32 mA, with a 130 mA surge for 100 ms at start-up, so size the regulator and any battery accordingly. Power consumption is 100 mW at 3.3 V. The output is a voltage from zero up to the rail minus 0.1 V. ION CONNECT communicates over UART and I2C and works with ION PC software for calibration, alarm thresholds and response factors; ION TRANSMIT adds RS-485 Modbus RTU and 4 to 20 mA outputs. The four order codes differ by intrinsically safe supply voltage window.
Approvals and environment
The sensor is certified ATEX II 1G Ex ia IIC Ga and IECEx for ambient temperatures from minus 40 to plus 55 degrees C at 1.1 W, and holds UL913 and CSA approvals for Class I, II and III Division 1. It operates from minus 40 to plus 65 degrees C and from 0 to 99 percent relative humidity without condensation. Sensor body life is stated as more than five years, lamp life as 10,000 hours.
Calibration strategy for a wide range
A wide-range sensor deserves a two-point approach. Zero in clean, dry air removes the baseline, and a span gas near the middle of the intended measuring range fixes the slope. Because the response of a PID is not perfectly linear over three orders of magnitude, many designers store a correction table or use a second span point at the top of the range. If your alarms sit at low and high levels, check the sensor with gas near each alarm point at commissioning. Keep records for each unit, including date, gas, concentration and output, so that later drift can be traced to the sensor, the lamp or the electronics.
Care of the sensor
Schedule lamp and electrode stack service according to the contamination at the site. Dust, oil mist and silicones are the usual enemies; a pre-filter helps. Calibrate using a gas close to the one you expect, record the response factor, and check zero in clean air at each service. The lamp-out diagnostic is not offered as a feature of this model’s key list, so monitor output behaviour and set service intervals in the host firmware.
Related items you may also need: ION Science Titan 2 Fixed Benzene Monitor | ION Science Tiger XT Handheld VOC Detector | Honeywell FSL100 Series UV, UV/IR and IR3 Flame Detector | All ION Science products.
ION Science MiniPID 2 PPB WR ordering checklist
- When the ION Science MiniPID 2 PPB WR replaces an installed unit, check the existing nameplate against the code on this page before ordering.
- Every enquiry for the ION Science MiniPID 2 PPB WR is answered with a written confirmation of the code and expected lead time.
- Use the attached datasheet to check the ION Science MiniPID 2 PPB WR ratings, dimensions and connection details against your drawings.
- We supply the ION Science MiniPID 2 PPB WR as part of our fire & gas detectors range to plants in Oman and the GCC.
- For critical duty, keeping one ION Science MiniPID 2 PPB WR as a site spare shortens downtime after a failure.
Documents and quotation
The ION Science MiniPID 2 PPB WR datasheet shows the performance table, approvals and order codes. We include the sensor datasheet with this page; it shows the drawings and the order codes. Send your RFQ stating the model, the order code that matches your supply voltage, the quantity, and your delivery location in Oman or the GCC.
Other Models in the MiniPID2 Range
Seven Star LLC supplies models from the MiniPID2 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ION Science MiniPID 2 PPB VOC PID Gas Sensor | Fire & Gas Detectors | View details |
| ION Science MiniPID 2 PPB WR Wide-Range PID Gas Sensor | Fire & Gas Detectors | You are viewing this model |
Datasheets & Documents
- Datasheet ION Science MiniPID 2 PPB WR Wide-Range PID Gas Sensor Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ION Science is a British maker of gas detection instruments, based in Fowlmere, Cambridgeshire. It has been active since 1989 and is best known for photoionisation detectors (PIDs) that measure volatile organic compounds at low concentrations. Its portable and fixed instruments are used for worker exposure monitoring, leak detection and environmental surveys.
Seven Star LLC is an independent supplier in Muscat. We list ION Science detectors for oil and gas, petrochemical and environmental users in Oman and the GCC.
ION Science company profile
| Active since | 1989, United Kingdom |
|---|---|
| Head office | Fowlmere, Cambridgeshire |
| Core technology | Photoionisation detection (PID) with patented Fence Electrode design |
| Product families | Tiger XT and Cub portable PIDs, Titan benzene monitor, Falco fixed detectors |
Milestones
- 1989: ION Science begins operating.
- 1998: Patents its PID sensor.
- 2002: Patents the Fence Electrode for humidity-resistant PIDs.
- 2017: Opens its head office in Fowlmere.
ION Science product series
The Tiger XT is a handheld VOC detector for hazardous areas, and the Titan 2 is a fixed benzene monitor.
A PID uses ultraviolet light to ionise volatile organic compounds and measures the resulting current, which allows detection down to ppb levels. Response factors convert the reading for each specific compound. General VOC detectors measure the total, while benzene-specific monitors separate benzene from other hydrocarbons, which matters because benzene has very low exposure limits.
Where ION Science detectors are used
Leak detection, confined space entry checks, worker exposure monitoring, refinery and terminal benzene monitoring, and environmental and soil surveys.
Ordering ION Science detectors: what we need
Send the model, the compounds and ranges, lamp type, hazardous-area requirement and accessories such as probes, filters and calibration kits.
Facts checked against ION Science's published company history, October 2026.
Browse ION Science products by category: Gas Analyzer Systems, Fire & Gas Detectors.
FAQ
Questions about the ION Science MiniPID 2 PPB WR Wide-Range PID Gas
Answers from our engineering team on installation, compatibility and integration.
01What are the detection limit and range of the ION Science MiniPID 2 PPB WR?
The datasheet gives a minimum detection limit of 20 ppb and a range above 200 ppm, with sensitivity above 5 mV per ppm and T90 under 8 seconds.
02Which order codes does the MiniPID 2 PPB WR have?
MP3SWBLBAU2, MP3SWBLBBU2, MP3SWBLBCU2 and MP3SWBLBNU2, which differ by the intrinsically safe supply voltage window from 3.0 up to 18 V.
03Is the PPB WR better than the PPB for high concentrations?
Yes. The PPB WR reaches above 200 ppm, whereas the PPB covers above 40 ppm, but the PPB has the lower 1 ppb detection limit.
04What temperature and humidity can the MiniPID 2 PPB WR operate in?
It operates from minus 40 to plus 65 degrees C and 0 to 99 percent relative humidity without condensation.
05Which communication kits work with the MiniPID 2 PPB WR?
ION CONNECT supports UART and I2C, and ION TRANSMIT offers RS-485 Modbus RTU and 4 to 20 mA output, both described in the datasheet.


















Reviews