- Automation & ControlView all 3,102 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ION Science
ION Science ARA200 Disposable Personal CO Detector
Description
Overview
Carbon monoxide gives no warning: it is colourless, odourless and binds to blood haemoglobin far more strongly than oxygen does. The ION Science ARA200 is the carbon monoxide member of the ION Science ARA range, a single gas badge that is worn, never serviced and thrown away at the end of its life. Seven Star LLC is an independent supplier serving Oman and the GCC. Everything on this page comes from the ARA brochure, version 1.1, rewritten for buyers who must keep contractors and plant operators safe around combustion equipment.
What you get with the ION Science ARA200
The unit measures 0 to 300 ppm CO using a single plug-in electrochemical cell. A 3.6 Vdc lithium battery rated 1.65 Ah is built in, and the brochure promises 24 months of operation on the standard model with two minutes of alarm per day. The hibernation sibling, ARA200H, stretches that to 36 months with a sleep function. The wearer sees live readings or a countdown of remaining life on a liquid crystal display, and gets warned by a 95 dB sounder at 10 cm, a bright LED and a vibrating alarm.
Operating is deliberately minimal: a single button. The same button starts the self test that checks the three alarm types, and reminders for bump testing and calibration can be configured so the badge nags its owner when a check is overdue.
Data sheet values for ION Science ARA200
| Item | Published value |
|---|---|
| Target gas and model | Carbon monoxide, ION Science ARA200 (ARA200H hibernation option) |
| Range | 0 to 300 ppm |
| Sensor | Plug-in electrochemical cell |
| Battery | 3.6 Vdc, 1.65 Ah lithium; 24 months standard, 36 months hibernation |
| Temperature | -40 to +60 degrees C; 5 to 95 percent RH |
| Ingress protection | IP67 |
| Audible and visual alarms | 95 dB at 10 cm, LED, vibrator (operates at plus or minus 10 degrees C) |
| Event memory | Last 30 events |
| Mass and envelope | 92 g; 87 x 50 x 29 mm |
| Shelf life | 12 months |
| Approvals | Class I Division 1 Groups A, B, C, D T4; Class I Zone 0 AEx ia IIC T4 Ga; Ex ia IIC T4 Ga |
Choosing ARA200 instead of its siblings
Pick the ION Science ARA200 when the hazard is incomplete combustion rather than sour gas. Its range, 0 to 300 ppm, is three times wider than the 0 to 100 ppm of the hydrogen sulphide model ARA100, and six times wider than the 0 to 50 ppm of the sulphur dioxide model ARA400. It is not an oxygen monitor: the ARA300 covers 0 to 25 percent oxygen and has a six month shelf life. The CO unit shares its temperature window of -40 to +60 degrees C and its twelve month shelf life with the H2S and SO2 units.
Typical jobs for the ION Science ARA200 in Oman and the GCC
Carbon monoxide hazards are everywhere in the Gulf where engines and burners run in confined places: generator rooms, boiler houses, compressor stations, tunnels, tank cleaning with portable engines, and welding in poorly ventilated spaces. The brochure lists oil and gas, manufacturing, government and defence, water, aerospace and power generation, and applications such as confined space entry, plant shutdown processes and first response. Disposable badges suit shutdown crews because they arrive configured and need no calibration rig.
Reading the lifetime counter
The lifetime-remaining countdown is the unique management feature of the ARA series. Instead of tracking dates in a spreadsheet, a supervisor can read how many days remain on the display. That helps schedule replacement before a long project begins: a unit with a few weeks left should not be issued for a three month shutdown. Via the optional IR Link and ARA PC software, users can also select whether the screen shows live gas or lifetime, download the 30 most recent events and set low and high alarm levels, user ID, and bump and calibration intervals.
Bump testing the ARA200
The ARA DOCK4, sold separately, bump tests or calibrates up to four detectors at the same time, saving gas and time, and stores readings together with serial number, date and time. Many sites run a bump test before every shift for life-critical alarms; the docking station makes this practical for a crew of dozens.
What a CO reading means in practice
Carbon monoxide effects depend on both concentration and exposure time, which is why exposure standards give a time-weighted average and a short-term limit. A badge with a 0 to 300 ppm span covers the region where those limits sit and the region where headaches and confusion begin. A low alarm gives the worker time to leave calmly, and the high alarm indicates an immediate evacuation. If a unit alarms near an engine exhaust, move to fresh air, report the event and let the event log record what happened for the incident file. Do not rely on sensation or smell, because carbon monoxide provides neither.
Fleet planning for ARA200
Estimate the number of workers who will need protection at the same time, add spares for failures and for staff who join later, and order so that the units arrive close to the start of the job. A disposable fleet does not need a calibration bench, but it does need a store, a rotation rule and a person responsible for running the bump test routine. Record each serial number against the worker who carries it so that an alarm event can be traced to the right person and location.
Care, storage and disposal
Store unused badges in a cool, dry store and rotate stock so that none passes its shelf life of twelve months. Wipe the case with a damp cloth, do not open it, and retire it when the countdown ends or when it fails a self test. Follow local rules for lithium battery disposal.
Ordering notes for ARA200
Specify the quantity, whether you need ION Science ARA200 or the hibernation model ARA200H, and whether accessories such as the IR Link and DOCK4 are wanted. Confirm the exact model number printed on the unit before ordering replacements.
Related items you may also need: ION Science Titan 2 Fixed Benzene Monitor | ION Science Tiger XT Handheld VOC Detector | Honeywell RAEGuard 3 Fixed Gas Detector Transmitter | All ION Science products.
Points to confirm for the ION Science ARA200
- If the ION Science ARA200 is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
- For each ION Science ARA200 request we confirm the exact code and lead time in writing.
- Dimensions, ratings and connection data for the ION Science ARA200 are in the datasheet attached to this page.
How to specify the exact ION Science ARA200 configuration
The ION Science ARA200 is offered as a model with several kit and accessory options, so the exact supply is defined by the points below rather than by the model name alone.
- Target gas or gases and the measuring range needed for the ION Science ARA200 application.
- Lamp or sensor option where the instrument offers more than one, for example the standard VOC lamp or a selective configuration.
- Hazardous area approval required for the site, such as ATEX or IECEx zone rating.
- Accessories needed with the unit, such as charger, calibration adaptor, sampling probe, carry case or docking station.
- Any data logging, software or calibration certificate requirement for your records.
Share these points, or the part number printed on an existing unit or previous order, and the quotation will list the confirmed kit contents.
Documents and quotation
The manufacturer’s ARA brochure is attached to this page as a datasheet. Send your RFQ with the part number ION Science ARA200, the quantity and your delivery location in Oman or the GCC and we will return availability and lead time.
Other Models in the ARA Range
Seven Star LLC supplies models from the ARA range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ION Science ARA100 Disposable Personal H2S Detector | Fire & Gas Detectors | View details |
| ION Science ARA200 Disposable Personal CO Detector | Fire & Gas Detectors | You are viewing this model |
Datasheets & Documents
- Datasheet ION Science ARA200 Disposable Personal CO Detector Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ION Science is a British maker of gas detection instruments, based in Fowlmere, Cambridgeshire. It has been active since 1989 and is best known for photoionisation detectors (PIDs) that measure volatile organic compounds at low concentrations. Its portable and fixed instruments are used for worker exposure monitoring, leak detection and environmental surveys.
Seven Star LLC is an independent supplier in Muscat. We list ION Science detectors for oil and gas, petrochemical and environmental users in Oman and the GCC.
ION Science company profile
| Active since | 1989, United Kingdom |
|---|---|
| Head office | Fowlmere, Cambridgeshire |
| Core technology | Photoionisation detection (PID) with patented Fence Electrode design |
| Product families | Tiger XT and Cub portable PIDs, Titan benzene monitor, Falco fixed detectors |
Milestones
- 1989: ION Science begins operating.
- 1998: Patents its PID sensor.
- 2002: Patents the Fence Electrode for humidity-resistant PIDs.
- 2017: Opens its head office in Fowlmere.
ION Science product series
The Tiger XT is a handheld VOC detector for hazardous areas, and the Titan 2 is a fixed benzene monitor.
A PID uses ultraviolet light to ionise volatile organic compounds and measures the resulting current, which allows detection down to ppb levels. Response factors convert the reading for each specific compound. General VOC detectors measure the total, while benzene-specific monitors separate benzene from other hydrocarbons, which matters because benzene has very low exposure limits.
Where ION Science detectors are used
Leak detection, confined space entry checks, worker exposure monitoring, refinery and terminal benzene monitoring, and environmental and soil surveys.
Ordering ION Science detectors: what we need
Send the model, the compounds and ranges, lamp type, hazardous-area requirement and accessories such as probes, filters and calibration kits.
Facts checked against ION Science's published company history, October 2026.
Browse ION Science products by category: Gas Analyzer Systems, Fire & Gas Detectors.
FAQ
Questions about the ION Science ARA200 Disposable Personal CO Detector
Answers from our engineering team on installation, compatibility and integration.
01What range does the ION Science ARA200 measure?
The ARA200 measures carbon monoxide from 0 to 300 ppm using a single plug-in electrochemical cell.
02How long does the ARA200 operate before disposal?
The standard model runs 24 months and the ARA200H hibernation version 36 months, assuming two minutes of alarm per day.
03What alarms does the ARA200 provide?
It has a 95 dB audible alarm at 10 cm, an LED visual alarm and a vibrating alarm, plus a self test that checks all three.
04Can I see how long the ARA200 has left?
Yes. The display can show live readings or a lifetime-remaining countdown, selectable through the ARA PC software with the optional IR Link.
05How is the ARA200 shelf life specified?
The brochure gives 12 months shelf life for the CO, H2S and SO2 models, against 6 months for the oxygen model.


















Reviews