Brand:

Hach 21680-42 DEHA Reagent 2 Solution

Description

Overview

Hach 21680-42 is a genuine Hach DEHA Reagent 2 Solution, supplied in a 100 mL bottle, formulated as the companion reagent to DEHA Reagent 1 for the determination of oxygen scavengers in boiler feedwater and process water systems by the iron reduction method. Used together under Hach Method 8140, the Hach 21680-42 solution enables plant chemists to accurately quantify diethylhydroxylamine (DEHA), carbohydrazide, hydroquinone, iso-ascorbic acid and methylethylketoxime concentrations, providing the analytical confirmation needed to verify correct oxygen scavenger dosing across steam and boiler water treatment programs.

With fast quotation turnaround and technical support, Seven Star LLC proudly supplies genuine Hach 21680-42 DEHA Reagent 2 Solution to industrial plants throughout Oman and the GCC. Every bottle shipped from our Muscat-based facility is sourced directly through Hach’s trusted supply channel, ensuring authentic reagent chemistry, correct shelf-life dating and full compatibility with existing Hach spectrophotometers and DR900-series colorimeters already deployed across regional power generation and process water laboratories.

Operating Principle

The Hach 21680-42 DEHA Reagent 2 is the ferric iron source in the two-part colorimetric reaction specified in Hach Method 8140. Dosed at 0.5 mL into the sample bottle and the reagent blank after the DEHA Reagent 1 powder pillow has been added, it supplies the ferric iron that the oxygen scavenger in the sample reduces to the ferrous state, in an amount equivalent to the scavenger concentration. The chromogenic chemistry of DEHA Reagent 1 then forms a purple complex with that ferrous ion, and the connected Hach spectrophotometer or colorimeter converts the resulting colour intensity into a quantitative reading across the method’s calibrated working range.

Because the reagent solution is factory formulated to a fixed concentration and dosing volume, results obtained using DEHA Reagent 2 alongside DEHA Reagent 1 provide plant chemists with consistent, repeatable analytical accuracy test after test. This reliability allows boiler water treatment programs to confidently verify oxygen scavenger residuals remain within the target dosing range needed to prevent dissolved oxygen corrosion in feedwater heaters, economizers, deaerators and boiler tubes, protecting high-value capital equipment from premature failure.

Engineering Design of the Hach 21680-42

The reagent is supplied as a ready-to-use liquid solution in a 100 mL amber or clear glass bottle designed for laboratory bench use, with a dropper or metered dispensing cap that delivers a consistent, repeatable dose volume for each test performed. This liquid format complements the powder pillow presentation of DEHA Reagent 1, together forming the complete two-reagent kit required to execute the Method 8140 procedure from start to finish.

The 100 mL bottle size is calibrated to support a substantial number of individual test doses before requiring replacement, matching typical laboratory consumption rates in power plant and process water testing programs. The solution is compatible with Hach DR-series spectrophotometers and portable colorimeters commonly deployed in boiler chemistry laboratories, integrating directly into existing Hach-based water quality testing workflows without requiring additional calibration equipment or method adaptation.

Key Features

The Hach 21680-42 DEHA Reagent 2 Solution delivers dependable performance around the following capabilities:

  • Completes the two-part Hach Method 8140 colorimetric procedure for oxygen scavenger determination.
  • Supplies the ferric iron that the oxygen scavenger reduces, driving the Method 8140 colour reaction.
  • Supplied as a ready-to-use 100 mL liquid solution with metered dispensing for consistent dosing.
  • Companion reagent to DEHA Reagent 1, together forming a complete testing kit for DEHA analysis.
  • Compatible with Hach DR-series spectrophotometers and portable colorimeters for lab or field testing.
  • Genuine Hach chemistry ensures repeatable, laboratory-grade analytical results across testing programs.
  • Supports oxygen scavenger verification across carbohydrazide, hydroquinone and DEHA dosing regimes.
  • Enables proactive boiler water treatment monitoring to prevent dissolved oxygen corrosion damage.

Dosing, Yield and Laboratory Handling

Chemically, the role of the Hach 21680-42 solution in Method 8140 is to supply the ferric iron that the oxygen scavenger reduces: DEHA, carbohydrazide, hydroquinone, iso-ascorbic acid or methylethylketoxime in the sample converts that ferric iron to the ferrous state, and the ferrous ion produced is what the accompanying powder pillow chemistry renders as a purple colour for photometric measurement. The published procedure calls for 0.5 mL of the solution to be added to the prepared 25 mL sample bottle and to the reagent blank, so a 100 mL bottle yields roughly 200 individual doses, or in the region of 100 paired sample-and-blank determinations before replacement is needed. Laboratories running high test volumes can specify the same chemistry in a 500 mL presentation (Hach 21680-49), or order both halves of the kit together as the Hach Oxygen Scavenger Reagent Set.

Because the reagent is a metered liquid rather than a sealed single-dose pillow, handling discipline matters more here than on the powder side of the kit. A dedicated dispenser or dropper should be used so that the bottle neck never contacts a reacted sample, the cap should be replaced immediately to limit evaporation and air oxidation of the ferric solution, and the bottle should be stored upright, tightly closed and away from direct sunlight and heat — a relevant point for laboratories in Oman where bench and store temperatures can swing widely. Seven Star LLC ships every bottle of Hach 21680-42 with its batch and expiry information intact, and the current safety data sheet is available on request for plant COSHH files before the reagent enters the laboratory.

Industrial Applications

The Hach 21680-42 DEHA Reagent 2 is used extensively in power generation plant chemistry laboratories, industrial steam boiler operations, and process water treatment facilities where oxygen scavenger dosing must be verified to protect high-pressure boiler and feedwater systems from corrosion damage. In Oman’s power generation and desalination sector, as well as petrochemical steam systems across Muscat, Sohar and Salalah, plant chemists rely on DEHA Reagent 2 in combination with Reagent 1 to confirm oxygen scavenger residuals remain within specification across daily and shift-based monitoring routines.

With engineering support in Muscat, Seven Star LLC supplies 21680-42 reagent bottles on request to power plant laboratories, water treatment operators and industrial testing contractors throughout the region, with lead time confirmed at quotation. Facilities across Sohar’s industrial port zone and Salalah’s free trade zone depend on Seven Star LLC for genuine Hach reagent chemistry with full batch traceability.

Technical Specifications

Parameter Specification
Model Hach 21680-42
Description DEHA Reagent 2 Solution
Method Hach Method 8140, Iron Reduction
Bottle Size 100 mL
Companion Reagent DEHA Reagent 1 (Hach 21679-69)
Application Boiler feedwater oxygen scavenger determination
Dose Volume 0.5 mL per 25 mL sample bottle and per blank
Approximate Yield ~200 doses per 100 mL bottle (~100 paired tests)
Function in Method Ferric iron source reduced by the oxygen scavenger
Measured Compounds DEHA, carbohydrazide, hydroquinone, iso-ascorbic acid, methylethylketoxime
Reaction Conditions 10 minutes in the dark (2 minutes for hydroquinone), 25 ± 3 °C
Alternative Pack Size 500 mL (Hach 21680-49)
Storage Upright, tightly closed, away from direct sunlight and heat
Compatible Instruments Hach DR-series spectrophotometers, colorimeters

Request a Quote for Hach 21680-42 DEHA Reagent 2 Solution

Seven Star LLC invites plant chemists and procurement teams across Oman and the GCC to submit a formal RFQ for the Hach 21680-42 DEHA Reagent 2 Solution. We supply on request with lead time confirmed at quotation, provide technical datasheets and method sheets on request, and offer direct access to our water analytics division for testing program support.

Related Products

Datasheets & Documents
  • PDF Instruction Manual Hach DEHA Oxygen Scavengers Method 8140 Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Water quality testing is the single subject Hach has worked on since 1947, from the reagent pillow in a field kit to online analyzers in a treatment plant. The company is based in Loveland, Colorado. Seven Star LLC lists Hach online analyzers, controllers, sensors, portable meters and reagents, and sources them for water, wastewater, power and process plants in Oman.

Hach analyzers, sensors and reagents listed

The Hach products on this page fall into four main groups, plus a few accessories such as a colorimeter, a reagent dispenser, a power supply and a flow control valve:

  • Online analyzers: CL17sc colorimetric chlorine analyzer, TU5300sc and TU5400sc laser turbidimeters, BioTector B3500ul TOC analyzer, Polymetron 9245 sodium analyzer and Orbisphere 510 dissolved gas analyzer
  • Controllers and digital sensors: SC4500 controller and the LDO 2 luminescent dissolved oxygen sensor
  • Portable and laboratory instruments: 2100Q turbidimeter, HQ4200 multi-parameter meter and IntelliCAL probes such as the LBOD101
  • Reagents: DPD free chlorine powder pillows and DEHA reagents for oxygen scavenger testing

Polymetron and Orbisphere analyzers are aimed at power plant water-steam cycles and similar pure water duties, where sodium, dissolved oxygen and other gases are measured at low levels.

Where Hach instruments are used

Hach instruments appear in drinking water plants, desalination, sewage treatment, cooling and boiler water circuits, and industrial effluent monitoring across the GCC. Operators use the portable meters and reagents for spot checks, and the sc analyzers and probes for continuous signals to the control system.

Ordering Hach products: what we need

Hach identifies every item by a catalog number, for example LXV416.99.20001 for a sensor or 21055-69 for a reagent pack, and the same reagent may be written with or without the dash. Send that number and the quantity. For analyzers and controllers, add the parameter and range, sample conditions, power supply, outputs and communication option. For sensors, tell us the controller model they will connect to and the cable length. For reagents, name the instrument and method so pack size and range can be confirmed against Hach documentation.

Frequently Asked Questions

What does Hach 21680-42 test for?
It is the DEHA Reagent 2 solution used with Hach Method 8140 to determine oxygen scavenger concentrations such as DEHA, carbohydrazide and hydroquinone in boiler feedwater by the iron reduction method.
Does it require special lab setup or reduce downtime?
No specialized titration setup is required. The ready-to-use liquid dosing format lets plant chemists complete the color development step quickly using a standard Hach spectrophotometer or colorimeter.
What is it compatible with?
It is compatible with Hach DR-series spectrophotometers and DR900 colorimeters, and must be paired with DEHA Reagent 1 (Hach 21679-69) to complete the Method 8140 test procedure.
Can it be used with older Hach spectrophotometer models?
Yes, the reagent chemistry is compatible with the full range of Hach DR-series spectrophotometers historically used across power plant chemistry laboratories, supporting legacy testing programs.
Is Seven Star LLC an experienced supply partner for Hach products?
Yes, Seven Star LLC is an experienced supplier of Hach in Oman and the GCC, supplying genuine reagents with full batch traceability.