Brand: Flowserve
Flowserve Atomac AKH3 Fluoropolymer Lined Ball Valve
Description
Flowserve Atomac AKH3 fluoropolymer lined standard-port ball valve
The Flowserve Atomac AKH3 is a fully lined ball valve for corrosive duty, in standard-port form to ASME dimensions. Its two-piece ductile iron body is lined with a thick fluoropolymer liner, and the ball and stem are fully encapsulated, so no metal touches the process fluid. The catalogue lists the AKH3 from 1 in (25 mm) through 12 in (300 mm), with Class 150 flanges and ASME B16.10 face-to-face lengths, so it can replace existing standard-port valves without changing the piping. Seven Star LLC supplies the AKH3 in Oman and the GCC as an independent supplier in Muscat.
Flowserve places the AKH3 next to its full-port AKH2A (ASME) and AKH2 (DIN) valves in the same catalogue, along with the AMP3 three-way valve and the AKH5 ceramic-lined valve. The choice between standard and full port is largely one of flow capacity versus cost and face-to-face dimensions.
How to read the Atomac model and ordering text
The catalogue ordering example is written as size, model, liner. For example, 4 AKH2A FEP means a 4 in (100 mm) AKH2A full-port valve with an FEP liner and an encapsulated ball. For the AKH3 the same pattern applies with these options.
| Element | AKH3 options in the catalogue |
|---|---|
| Size | 1 to 12 in (25 to 305 mm), standard port, ASME |
| Liner | PFA, FEP, PP or PVDF |
| Body material | Ductile cast iron (DCI) or CF8M stainless steel |
| Special ball for 1 to 3 in | V (V-port), C (characterized), CER (ceramic ball up to 6 in) |
| Stuffing box | Single or double stuffing box (DB/SB) |
AKH3 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Flowserve / Atomac AKH3 (standard-port fully lined ball valve) |
| Size range | 1 to 12 in (25 to 300 mm) |
| Flange standard | ASME B16.5 Class 150 (DIN 2501 / PN 16); ASME B16.10 face-to-face |
| Body | Two-piece ductile iron ASTM A395 60-40-18 (GGG40.3) with B7 fasteners; B8 as alternate; stainless steel optional |
| Liner | FEP to 150 °C (300 °F) or PFA to 200 °C (400 °F); polypropylene or PVDF options |
| Pressure | Full vacuum to 19 bar (275 psi) |
| Seats | PTFE seat rings |
| Stem | CD-4MCu (1.4462) insert coated with PFA, anti-blowout |
| Stem seal | PTFE chevron packing, adjustable gland with PTFE-graphite bearing |
| Leak test | API 598 or DIN 3230 criteria |
| Mounting pad | ISO 5211 universal pad for automation |
| Face-to-face L | 1 in 127 mm; 2 in 178 mm; 4 in 229 mm; 6 in 267 mm; 8 in 292 mm; 12 in 356 mm |
| Lockout | Standard on the AKH3 |
| Minimum service temperature | For applications below 14 °F (–10 °C), consult the manufacturer |
How the AKH3 resists corrosion and sustains leak tightness
The liner is locked into the body by T slots and locking grooves, and the thick liner is 100 % inspected at 20,000 volts DC for defects. The ball is a floating design that seals against replaceable PTFE seats, and a separate ball/stem connection reduces side loading on the stem seal. A graphite bearing prevents side loading, an anti-blowout stem assembly stays captive even if the top works are removed, and the cavity space is kept small so little process fluid is retained. A C-ball option eliminates media build-up in the ball cavity.
Where the AKH3 fits among Atomac and Flowserve valves
The catalogue also lists the AMP3 and AKH6 three-way and tank-drain variants, AKH7 glass pipe valves, check valves, sight glasses, sampling valves and strainers, which together make up a lined pipework system. For automation, the ISO 5211 pad accepts Flowserve Automax actuators; characterised-ball rotary control valve packages are available for throttling. The Automax RG and SuperNova actuators on this site fit this role.
Selection checklist for the AKH3
- Fluid composition and concentration, with temperature and pressure; FEP limit 150 °C, PFA limit 200 °C.
- Vacuum or pressure service; the rating is full vacuum to 19 bar.
- Size and flange class (Class 150 only).
- Liner: FEP, PFA, PP or PVDF; ball type: standard, V, C or ceramic.
- Body: ductile iron or CF8M stainless steel.
- Packing: standard or extended packing with purge connection and live loading for fugitive emissions (TA Luft certified option).
- Stem extension if the valve is insulated.
- Manual lever or actuator on the ISO 5211 pad; chlorine cleaning if required.
Installation, commissioning and maintenance
Lined valves are installed between mating flanges with full-face gaskets and the bolting tightened gradually in a star pattern to avoid distorting the liner. Follow the manufacturer instructions for gasket type and bolt torque so the liner is not over-compressed. Operate the valve a few times before commissioning, check the packing gland and torque and, on automated valves, set the open and closed stops. Maintenance is simple: replace the PTFE seat rings and the stem packing, which can be done after the valve is removed from the line.
Typical applications of the AKH3 in Oman and the GCC
Lined ball valves are common in acid and caustic handling, chlorine and hypochlorite systems for desalination and water treatment, sulphuric acid and sodium hydroxide dosing, and in chemical units for aggressive solvents and ammonia services. The ability to handle vacuum is useful in distillation and evaporator duty. In Oman and the GCC, seawater desalination dosing skids and power plant chemical-cleaning systems are good matches.
Information to send with your AKH3 RFQ
- Fluid and concentration, temperature and pressure range.
- Size, flange standard and number of valves.
- Liner and ball options, stem extension and packing type.
- Manual operation or actuator details.
- Special cleaning, such as chlorine service.
- Delivery site.
Site conditions in Oman for the AKH3
Valves and their accessories in Oman work in demanding conditions: high ambient temperatures, direct sun on outdoor pipe racks, dust, and corrosive coastal air at many oil, gas and water sites. When you specify the AKH3, confirm the pressure and temperature ratings, body and trim materials and any sour-service or hazardous-area requirements against the actual line data, and check that seals and soft parts suit the process medium and the full temperature range.
For reliable operation, plan access for maintenance, define which spare parts are kept on site, and record the configuration of each installed AKH3. Sending the complete process data sheet with your RFQ allows the selection to be checked before the order is placed.
Documents and quotation
The Flowserve Atomac lined ball valve catalogue (ATENTB0010) is attached on this page. Send your duty data and we will confirm availability and lead time. Seven Star LLC is an independent supplier and does not claim any official status with the manufacturer.
See also: Flowserve Worcester Series 44 Three-Piece Ball Valve.
Datasheets & Documents
- Catalog Flowserve Atomac Lined Ball Valve Catalog ATENTB0010 Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Flowserve is the American flow control company for pumps, valves, mechanical seals and valve automation, known through brands such as Durco, Worthington, Byron Jackson, Valtek, Limitorque, Worcester, Logix and Argus. It was formed on 22 July 1997 by the merger of equals of Durco International and BW/IP, whose heritage reaches back to Simpson & Thompson (1790) and Byron Jackson (1872). Flowserve Corporation is headquartered in Irving, Texas, and listed on the New York Stock Exchange.
Seven Star LLC sources and supplies Flowserve pumps, seals, control valves, ball valves, actuators and positioners for process plants in Oman, working from the nameplate data and the manufacturer's documentation.
Flowserve company profile
| Formed | 22 July 1997, merger of Durco International and BW/IP |
|---|---|
| Heritage companies | Simpson & Thompson, later Worthington Simpson (1790); Byron Jackson (1872); Duriron foundry, later Durco (1912) |
| Headquarters | Irving, Texas, USA |
| Ownership | Flowserve Corporation, public company (NYSE: FLS) |
| Product families | API and ANSI process pumps, Durco and Worcester ball and plug valves, Durco TX3 triple-offset and Valtek butterfly and globe control valves, Limitorque electric actuators, Logix positioners, mechanical seals |
Milestones
- 1790: Thomas Simpson founds Simpson & Thompson, a predecessor of Worthington Simpson pumps.
- 1872: Byron Jackson is founded, a root of BW/IP.
- 1912: The Duriron foundry, later Durco, is launched.
- 1997: Durco International and BW/IP merge on 22 July to form Flowserve, listed on the NYSE as FLS.
Flowserve product families listed here
Flowserve pumps on this page are the Durco Mark 3 ANSI process pump and the ECPJ vertical sump pump built to API 610 type VS4. Sealing products are the ISC2 cartridge mechanical seal to API 682 and DuraClear barrier fluid for dual seal systems. Flowserve valves include the Valtek Mark One globe control valve, Argus floating and trunnion-mounted ball valves (EK71, FK79, FK76M) and Durco Microfinish ball valves. Automation is covered by Limitorque MX and L120 multi-turn electric actuators, the Rotadisk RD and RDF pneumatic actuator and the Logix 3800 digital positioner.
Where Flowserve equipment is used
Mark 3 pumps handle acids, caustic, solvents and utilities in chemical and petrochemical units. VS4 sump pumps drain pits and collection tanks. Valtek control valves and Argus ball valves are found in refining, gas processing, power and desalination, and Limitorque actuators operate gate and globe valves on pipelines, tank farms and water networks across the GCC.
Flowserve products we list
Ordering Flowserve parts: what we need
The serial number on the nameplate is the key to Flowserve records for a pump, valve or actuator. Please add the following by product type:
- Pumps: size and model, impeller diameter, materials, seal arrangement, and the part name and item number from the sectional drawing
- Mechanical seals: seal type and size, drawing or part number, materials code, pumped fluid and flush plan
- Valves: size, pressure class, body and trim materials, end connections, and the actuator and positioner model
- Limitorque actuators: unit size, order and serial number, supply voltage, wiring diagram number
Facts checked against Flowserve's SEC filings and published company histories, October 2026.
Browse Flowserve products by category: Control Valves, Pumps, Valve Actuator, Valve Positioner.
FAQ
Questions about the Flowserve Atomac AKH3 Fluoropolymer Lined Ball Valve
Answers from our engineering team on installation, compatibility and integration.
01What is the Flowserve Atomac AKH3?
It is a standard-port, fully fluoropolymer lined ball valve with a two-piece ductile iron body, encapsulated ball and stem, ASME Class 150 flanges and sizes from 1 to 12 in.
02What temperature limits apply to the AKH3?
The FEP liner is rated to 150 °C (300 °F) and the PFA liner to 200 °C (400 °F). For applications below –10 °C, consult the manufacturer.
03Can the AKH3 be used in vacuum?
Yes. The catalogue states the liner and body can handle pressures from full vacuum to 275 psi (19 bar).
04How does the AKH3 differ from the AKH2A?
The AKH3 is standard port with short-pattern ASME dimensions for 1 to 12 in. The AKH2A is a full-port valve in ASME dimensions for 1 to 6 in with higher flow capacity.
05How is the AKH3 automated?
An ISO 5211 universal mounting pad allows an actuator to be fitted easily, even with the valve in the pipeline.