Brand:

Eaton NZMN2-A160 Molded Case Circuit Breaker 160 A 3-Pole

Description

Eaton NZMN2-A160 molded case circuit-breaker, 160 A, three-pole

The Eaton NZMN2-A160 (catalog number 259092) is a three-pole molded case circuit-breaker from the NZM series, frame size NZM2, with a thermomagnetic release for 160 A. The overload setting is adjustable from 125 to 160 A and the instantaneous setting from 960 to 1600 A. According to the sheet title the breaking capacity is 50 kA at 400/415 V, 50 Hz. It is a fixed-mounted device with screw connection, designed for the protection of feeders, distribution boards and large motors. Seven Star LLC supplies the NZMN2-A160 in Oman and the GCC for switchgear builders, contractors and plant maintenance teams.

Reading the NZMN2-A160 model code

NZM is the series name for Eaton molded case circuit-breakers. The letter N after NZM is the breaking-capacity class; the S class of the same frame, such as the NZMS2-A160, has a higher breaking capacity at 400/415 V. The number 2 is the frame size, NZM2, which covers ratings up to 250 A in the range. A160 describes the release: thermomagnetic with a rated current of 160 A. The neighbouring ratings include the NZMN1-A80, the NZMN2-A250 and the NZMN3-AE400.

NZMN2-A160 technical specifications

Parameter Specification
Manufacturer / part number Eaton NZMN2-A160 (catalog number 259092)
Series Eaton Moeller NZM molded case circuit-breaker
Frame size NZM2
Number of poles Three-pole
Release system Thermomagnetic release
Rated current / amperage rating 160 A
Overload current setting Ir 125 – 160 A
Instantaneous current setting Ii 960 – 1600 A
Rated operational voltage 690 V AC; 750 V DC rating listed
Rated insulation voltage Ui 1000 V AC
Rated impulse withstand voltage Uimp, main / auxiliary contacts 8000 V / 6000 V
Utilization category A (IEC/EN 60947-2)
Overvoltage category III
Rated short-time withstand current, 0.3 s and 1 s 1.9 kA
Short-circuit total break time Less than 10 ms
Handle Rocker lever
Mounting Fixed built-in; DIN rail mounting optional
Degree of protection IP20 basic; IP40 front with insulating surround; IP66 with door-coupling rotary handle; terminals IP10 (tunnel) / IP00
Protection against direct contact Finger and back-of-hand proof, DIN EN 50274 / VDE 0106 part 110
Shock resistance 20 g (half-sinusoidal, 20 ms)
Ambient storage temperature −25 to 70 °C
Maximum operations per hour 120
Short-circuit breaking capacity, 230 V 85 kA
Short-circuit breaking capacity, 400/415 V 50 kA
Short-circuit breaking capacity, 440 V 35 kA
Short-circuit breaking capacity, 525 V 25 kA
Short-circuit breaking capacity, 690 V 5 kA
Short-circuit breaking capacity, 500 V DC / 750 V DC 7.5 kA / 7.5 kA
Short-circuit making capacity Icm, 240 V / 400/415 V 187 kA / 105 kA
Short-circuit making capacity Icm, 440 V / 525 V / 690 V 74 kA / 53 kA / 40 kA
Mechanical lifespan 20,000 operations
Dimensions (depth x height x width) 149 x 184 x 105 mm
Weight 2.321 kg
Equipment heat dissipation at rated current 38.4 W

The breaking-capacity rows follow the table in the manufacturer specification sheet for catalog number 259092, where they are listed under the short-circuit breaking capacity headings; for protection coordination, consult the full sheet or the NZM technical information for Icu and Ics at each voltage.

How the NZMN2-A160 protects a circuit

The thermomagnetic release combines two elements. A bimetal element reacts to sustained overcurrent, and its setting is adjustable between 125 and 160 A, so the breaker can be matched to the actual feeder or motor current. A magnetic element reacts to short circuits, adjustable from 960 to 1600 A, which equals six to ten times the rated current. When either element trips, the breaker opens all three poles at once, with a total break time under 10 ms in the short-circuit range.

The breaker is utilization category A, meaning it is not designed for deliberate short-time delay for selectivity, and it carries a rated short-time withstand current of 1.9 kA. Breaking capacity depends on voltage: 50 kA at 400/415 V, 35 kA at 440 V, 25 kA at 525 V and 5 kA at 690 V according to the sheet. The rated impulse withstand voltage of the main contacts is 8000 V and the insulation voltage is 1000 V AC.

Where the NZMN2-A160 fits in a distribution system

A 160 A molded case breaker normally serves as an outgoing feeder protection in a main distribution board, as an incomer for a sub-distribution board, or as the protective device of a large motor, pump or compressor feeder. The NZMN2-A160 can be fitted with accessories such as auxiliary contacts, shunt trips, undervoltage releases and a motor drive, as indicated by the sheet entry that a motor drive and protection unit are optional. For smaller feeders the NZMN1-A80 is a lower rating, while the NZMN2-A250 covers the upper end of the NZM2 frame.

Selection checklist for the NZMN2-A160

  • Confirm the load current at the operating voltage and set Ir inside 125 to 160 A, with the cable rating in mind.
  • Compare the prospective short-circuit current with the breaking capacity at your voltage: 50 kA at 400/415 V, 5 kA at 690 V.
  • Consider the S version, the NZMS2-A160, if fault levels exceed the N class.
  • Choose accessories before ordering: auxiliary contacts, shunt trip, handle options and terminals.
  • Check the enclosure and door cut-out for the 105 mm width and the rotary handle if IP66 front protection is needed.
  • Verify the temperature rating: derating may apply in hot panels.

Installation and commissioning of the NZMN2-A160

The breaker is fixed-mounted on a plate or on a DIN rail where the optional mounting is used. Connect the supply and load conductors to the screw terminals or to the rear-side connection, following the instruction leaflet for cable sizes and torque, and keep the terminal covers in place. Set Ir and Ii on the release unit, test the trip with the push-to-trip button at commissioning, and record settings. Maintenance includes visual checks for heat marks at terminals, a periodic mechanical operation and checks after any short-circuit trip, following the manufacturer guidance.

Typical applications in Oman and the GCC

In Oman and the GCC, 160 A molded case breakers are used in motor control centres, utility distribution boards, pump stations, desalination plant auxiliaries and industrial buildings. Heat is the main design factor: enclosure temperatures should be checked against breaker ratings, and ventilation provided. Dust and humidity favour sealed boards, and the optional IP66 door-coupling handle keeps front protection high.

Eaton NZM2 and neighbouring ratings

Model Rating / frame Note
NZMN2-A160 125 – 160 A 50 kA at 400/415 V, standard breaking capacity
NZMS2-A160 125 – 160 A 70 kA at 400/415 V, higher breaking capacity
NZMN2-A250 Frame NZM2, 250 A Larger NZM2 rating
NZMN1-A80 Frame NZM1, 80 A Smaller frame
NZMN3-AE400 Frame NZM3, 400 A Larger frame, electronic release

The table places the device within the NZM range; ratings of neighbouring devices must be confirmed from their own sheets.

Information to send with an RFQ for NZMN2-A160

  • Exact model NZMN2-A160 (catalog number 259092) and the quantity, including spares.
  • Required Ir setting range and load type.
  • Prospective short-circuit current and system voltage.
  • Accessories: auxiliary contacts, shunt trip, motor drive, handle and terminals.
  • Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
  • Any documents you need with the quotation, such as an installation leaflet or declaration of conformity.

Documents and quotation

The manufacturer specification sheet for NZMN2-A160 is attached on this page, so you can check the ratings, dimensions and approvals against your project before you order. Installation leaflets and declarations of conformity can be requested separately.

Seven Star LLC supplies Eaton industrial control products in Oman and the GCC. To request a quotation, send model NZMN2-A160, the quantity and your delivery location, and we will confirm availability and lead time for your order.

Other Models in the Eaton Nzm2 Range

Seven Star LLC supplies models from the Eaton Nzm2 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Eaton NZMN2-A160 Molded Case Circuit Breaker 160 A 3-PoleCircuit BreakersYou are viewing this model
Eaton NZMS2-A160 Molded Case Circuit Breaker 160 A 70 kACircuit BreakersView details
Datasheets & Documents
  • PDF Datasheet Eaton NZMN2-A160 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.

Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.

Eaton company profile

Founded 1911, New York, USA, by Joseph O. Eaton
Early move Cleveland, Ohio, 1914
Headquarters Dublin, Ireland, since the 2012 Cooper Industries acquisition
Listing New York Stock Exchange (ETN)
Brands Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC
Product families FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling

Milestones

  • 1911: Joseph O. Eaton starts an axle business in New York.
  • 1914: The business moves to Cleveland.
  • 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.

Eaton circuit protection listed here

The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.

Where Eaton breakers and fuses are used

Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.

Eaton products we list

Family Examples
Circuit Breakers LPJ-35SP Class J Time-Delay Fuse, NZMN1-A80 Molded Case Circuit Breaker, NZMN2-A250 Molded Case Circuit Breaker, NZMN3-AE400 Molded Case Circuit Breaker, PKZM0-1
AC Drives DA1-342D2FB-A20C AC Drive, PowerXL DG1-34140FN-C21C Variable Freque…

Ordering Eaton parts: what we need

Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.

Facts checked against Eaton's corporate history and investor materials, October 2026.

FAQ

Questions about the Eaton NZMN2-A160 Molded Case Circuit Breaker 160 A

Answers from our engineering team on installation, compatibility and integration.

01What current rating does the NZMN2-A160 have?
It is rated 160 A with a thermomagnetic release. The overload setting Ir is adjustable from 125 to 160 A and the instantaneous setting from 960 to 1600 A.
02What is the breaking capacity of the NZMN2-A160?
The sheet title gives 50 kA at 400/415 V and 50 Hz. The table also lists 85 kA at 230 V, 35 kA at 440 V, 25 kA at 525 V and 5 kA at 690 V.
03What are the dimensions and weight of the NZMN2-A160?
The sheet lists 149 mm depth, 184 mm height and 105 mm width, with a weight of 2.321 kg. It is a fixed-mounted three-pole device.
04What degree of protection does the NZMN2-A160 offer?
IP20 as basic protection, IP40 on the front with an insulating surround and IP66 with a door-coupling rotary handle. Terminals are IP10 for tunnel terminals and IP00 otherwise.
05What is the difference between the NZMN2-A160 and NZMS2-A160?
Both are NZM2 breakers with 160 A thermomagnetic release. The S version has a higher breaking capacity, 70 kA at 400/415 V against 50 kA for the N version, per the sheets.