Brand:

Eaton FAZ-C16/3-NA Miniature Circuit Breaker 3-Pole 16 A UL 489

Description

Eaton FAZ-C16/3-NA miniature circuit breaker, three-pole, 16 A, UL 489 version

The Eaton FAZ-C16/3-NA (catalog number 102250) is the North American version of the three-pole FAZ miniature circuit breaker with C characteristic and 16 A rated current. It is listed to UL 489 with a breaking capacity of 14 kA and to IEC 60947-2 with an Icu of 25 kA at 230 V and 400 V, and it carries a voltage rating of 277/480 V AC for UL installations. The sheet describes it as switchgear for export to North America, suitable as a branch circuit protective device. Seven Star LLC supplies the FAZ-C16/3-NA in Oman and the GCC for projects where UL-listed equipment is specified, such as equipment built to North American standards.

Decoding FAZ-C16/3-NA

FAZ is the miniature circuit breaker family, C the tripping characteristic, 16 the rated current in amperes and 3 the number of poles. The suffix -NA stands for North America: the device is certified to UL 489 and CSA C22.2 No. 5 and has screw terminals with pressure plates and tightening torques given for AWG conductors. The standard IEC version of the same rating is the FAZ-C16/3, with lower breaking capacity and twin-purpose terminals.

FAZ-C16/3-NA technical specifications

Parameter Specification
Manufacturer / part number Eaton FAZ-C16/3-NA (catalog number 102250)
Series Eaton Moeller xEffect FAZ-NA
Number of poles Three-pole
Tripping characteristic C
Rated current In 16 A
Rated operational voltage Ue, max 440 V AC
Voltage rating (UL) 277 V AC / 480 V AC; 480Y/277 V
Voltage rating (IEC/EN 60947-2) 240/415 V AC
Breaking capacity to UL 489 14 kA
Rated short-circuit breaking capacity Icu (IEC 60947-2) at 230 V and 400 V 25 kA
Rated switching capacity (IEC/EN 60947-2) at maximum voltage 15 kA
Current-limiting class / selectivity class 3 / 3
Functions Overload protection, short-circuit protection
Direction of incoming supply Bidirectional
Electrical lifespan 20,000 operations
Internal resistance per pole at room temperature 8 mΩ
Mounting Top-hat rail
Mounting width per pole 17.7 mm; total width 53.1 mm
Terminals Screw type with pressure plate, top and bottom; conductor up to 25 mm²
Tightening torque (UL) 2.4 Nm for AWG 18–12; 2.8 Nm for AWG 10–8; 4 Nm for AWG 6
Degree of protection IP20 (IEC); IP40 when fitted; UL/CSA type IP20
Weight 0.365 kg

The data follows the manufacturer specification sheet for catalog number 102250. The sheet lists certifications to UL 489, CSA C22.2 No. 5, IEC/EN 60947-2 and CE marking, and notes suitability as a branch circuit protective device; it also lists EN 45545-2 and IEC 61373 for railway use.

What makes the FAZ-C16/3-NA a UL 489 breaker

In North America, branch circuit breakers are tested and listed to UL 489, a standard with its own breaking-capacity ratings and marking requirements. The FAZ-C16/3-NA carries that listing, with a UL 489 breaking capacity of 14 kA at its voltage rating of 277/480 V AC, and a 480Y/277 V rating for three-phase systems with a grounded neutral. At the same time it is rated to IEC 60947-2 with an Icu of 25 kA at 230 V and 400 V, so it can be used where both approval systems matter.

The sheet describes bidirectional incoming supply, meaning line and load can be connected either way round, and an electrical lifespan of 20,000 operations, twice that of the IEC version. The internal resistance of 8 milliohm per pole helps keep heat low at 16 A.

Where the FAZ-C16/3-NA is used

The device is chosen for equipment built to North American standards that is installed in Oman and the GCC: skid-mounted packages, containerised systems, imported machines and projects whose specifications require UL-listed protective devices. The sheet lists typical applications such as industrial and commercial panels, OEM control panels, utility panels, HVAC and motor branch circuits, and railway and transport systems. For motor overload protection a motor-protective breaker is still required in addition.

Selection checklist for the FAZ-C16/3-NA

  • Confirm that the project specification requires UL 489 or UL-listed devices; otherwise the IEC FAZ-C16/3 is simpler.
  • Check the system voltage against the 277/480 V AC rating.
  • Compare the prospective short-circuit current with 14 kA (UL 489) or 25 kA Icu (IEC) as appropriate.
  • Use conductors and torque values specified for UL installations: 2.4 Nm for AWG 18 to 12.
  • Confirm that three modules of width, 53.1 mm in total, fit the board layout.

Installation and maintenance of the FAZ-C16/3-NA

Snap the breaker onto the rail and connect conductors to the screw terminals with pressure plates. Follow the UL torque values from the sheet: 2.4 Nm for AWG 18 to 12, 2.8 Nm for AWG 10 to 8 and 4 Nm for AWG 6. As incoming supply can be applied from either side, label the board accordingly. During inspections check terminals for heat marks and operate the toggle occasionally.

Typical applications in Oman and the GCC

Oil and gas and industrial projects in Oman often import skids and packages built to North American standards. The FAZ-C16/3-NA lets the installer replace or add branch circuit protection on such equipment with a device carrying the same listing. Hot ambient conditions call for margin in current rating.

Eaton FAZ 16 A models at a glance

Model Type Note
FAZ-C16/3 Three-pole, C, 16 A Version for IEC installations, 10 kA Icn at 400 V
FAZ-C16/3-NA Three-pole, C, 16 A Version for North America, UL 489 listed, 14 kA
FAZ-C16/3-RT Three-pole, C, 16 A Current-limiting FAZ-RT version
FAZ-C16/2-NA-AS Two-pole, C, 16 A NA-AS version

The table lists related 16 A FAZ devices; confirm ratings and approvals of each from its own sheet.

Information to send with an RFQ for FAZ-C16/3-NA

  • Exact model FAZ-C16/3-NA (catalog number 102250) and the quantity, including spares.
  • Whether UL 489 listing is required by the project.
  • System voltage, rated current and number of poles.
  • Conductor type and size.
  • Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
  • Any documents you need with the quotation, such as an installation leaflet or declaration of conformity.

Documents and quotation

The manufacturer specification sheet for FAZ-C16/3-NA is attached on this page, so you can check the ratings, dimensions and approvals against your project before you order. Installation leaflets and declarations of conformity can be requested separately.

Seven Star LLC supplies Eaton industrial control products in Oman and the GCC. To request a quotation, send model FAZ-C16/3-NA, the quantity and your delivery location, and we will confirm availability and lead time for your order.

Other Models in the Eaton Faz Range

Seven Star LLC supplies models from the Eaton Faz range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Eaton FAZ-C16/3 Miniature Circuit Breaker 3-Pole C 16 ACircuit BreakersView details
Eaton FAZ-C16/3-NA Miniature Circuit Breaker 3-Pole 16 A UL 489Circuit BreakersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Eaton FAZ-C16/3-NA Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.

Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.

Eaton company profile

Founded 1911, New York, USA, by Joseph O. Eaton
Early move Cleveland, Ohio, 1914
Headquarters Dublin, Ireland, since the 2012 Cooper Industries acquisition
Listing New York Stock Exchange (ETN)
Brands Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC
Product families FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling

Milestones

  • 1911: Joseph O. Eaton starts an axle business in New York.
  • 1914: The business moves to Cleveland.
  • 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.

Eaton circuit protection listed here

The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.

Where Eaton breakers and fuses are used

Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.

Eaton products we list

Family Examples
Circuit Breakers LPJ-35SP Class J Time-Delay Fuse, NZMN1-A80 Molded Case Circuit Breaker, NZMN2-A250 Molded Case Circuit Breaker, NZMN3-AE400 Molded Case Circuit Breaker, PKZM0-1
AC Drives DA1-342D2FB-A20C AC Drive, PowerXL DG1-34140FN-C21C Variable Freque…

Ordering Eaton parts: what we need

Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.

Facts checked against Eaton's corporate history and investor materials, October 2026.

FAQ

Questions about the Eaton FAZ-C16/3-NA Miniature Circuit Breaker 3-Pole

Answers from our engineering team on installation, compatibility and integration.

01What approvals does the FAZ-C16/3-NA carry?
The sheet lists UL 489, CSA C22.2 No. 5, IEC/EN 60947-2 and CE marking, and says it is specially designed for North America and suitable as a branch circuit protective device.
02What is the breaking capacity of the FAZ-C16/3-NA?
14 kA to UL 489, and Icu of 25 kA at 230 V and 400 V to IEC 60947-2. The switching capacity at maximum voltage is listed as 15 kA.
03What voltage rating does the FAZ-C16/3-NA have?
The UL voltage rating is 277/480 V AC, with 480Y/277 V for three-phase systems. The IEC voltage rating is 240/415 V AC and the maximum operational voltage is 440 V AC.
04How should the FAZ-C16/3-NA be connected?
Conductors go into screw terminals with pressure plates. The UL tightening torques are 2.4 Nm for AWG 18 to 12, 2.8 Nm for AWG 10 to 8 and 4 Nm for AWG 6.
05Is the incoming supply direction fixed on the FAZ-C16/3-NA?
No. The sheet lists bidirectional incoming supply, so line and load terminals can be used from either side.