Eaton PKE12/AK/XTU-12 Motor-Protective Breaker with AK Handle
Description
Eaton PKE12/AK/XTU-12 electronic motor-protective breaker with lockable AK handle
The Eaton PKE12/AK/XTU-12 (catalog number 158243) is the lockable-handle version of the PKE12/XTU-12 electronic motor-protective circuit-breaker. It uses the same PKE12 basic device and XTU-12 trip block, with a setting range of 3 to 12 A and a rated operational power of 5.5 kW at 380/400 V, 50 Hz, but replaces the standard knob with an AK lockable rotary handle. The result is a motor breaker that can be padlocked in the off position, which is a common requirement for isolation during maintenance. Seven Star LLC supplies the PKE12/AK/XTU-12 in Oman and the GCC.
Understanding PKE12/AK/XTU-12
The code has three parts. PKE12 is the basic device, AK marks the lockable rotary handle, and XTU-12 is the 3 to 12 A electronic trip block. Catalog number 158243 is the complete device with AK handle; its sibling 121733 (PKE12/XTU-12) has the standard knob, and 158241 (PKE12/AK) is the basic device with AK handle but without trip block. The AK handle makes the device 120 mm high, compared with 102.5 mm for the standard knob version.
PKE12/AK/XTU-12 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Eaton PKE12/AK/XTU-12 (catalog number 158243) |
| Series | Eaton Moeller PKE |
| Product category | Motor-protective circuit-breaker, electronic, three-pole |
| Rated operational voltage Ue | 690 V, 50/60 Hz |
| Rated impulse withstand voltage Uimp | 6000 V AC |
| Overvoltage category / pollution degree | III / 3 |
| Actuator | Turn button |
| Functions | Motor protection, overload release, protection for heavy starting duty, phase-failure sensitive |
| Short-circuit release | Basic device fixed at 15.5 × Iu; trip block fixed at 15.5 × Ir, delayed approx. 60 ms (±20 %) |
| Setting range (overload release) | 3 – 12 A |
| Rated operational current Ie / Iu | 12 A / 12 A |
| Rated operational power AC-3e, 230 V / 400 V / 440 V, 50 Hz | 3 kW / 5.5 kW / 5.5 kW |
| Rated operational power AC-3e, 500 V / 690 V, 50 Hz | 5.5 kW / 7.5 kW |
| Heat dissipation, total / per pole | 3.6 W / 1.2 W |
| Resistance per pole | 7.7 mΩ |
| Dimensions (depth x height x width) | 101 x 120 x 45 mm |
| Weight | 0.425 kg |
| Fitted with | AK lockable rotary handle |
| Mechanical / electrical lifespan | 50,000 operations each (electrical at 400 V, AC-3) |
| Operating frequency | 60 operations per hour |
| Ambient operating temperature | −25 to 55 °C open; −25 to 40 °C enclosed |
| Ambient storage temperature | −40 to 80 °C |
| Temperature compensation | −5 to 40 °C to IEC/EN 60947, operating range −25 to 55 °C |
| Degree of protection | IP20; terminals IP00 |
| Connection | Screw terminals, 1 or 2 × 1–6 mm² with ferrule, AWG 14–10, 10 mm stripping, 1.7 Nm main / 1 Nm control |
| Mounting | 35 mm top-hat rail |
The sheet also lists assigned motor power for North American ratings at 60 Hz: 1 HP at 115/120 V and 1.5 HP at 230/240 V single-phase; 3 HP at 200/208 V and 230/240 V, 7.5 HP at 460/480 V and 10 HP at 575/600 V three-phase.
Why choose the AK handle on the PKE12/AK/XTU-12
The electrical data of the PKE12/AK/XTU-12 is identical to that of the standard-knob device: electronic overload protection, phase-failure sensitivity to IEC/EN 60947-4-1, protection for heavy starting duty and a short-circuit release fixed at 15.5 times the rated current. What changes is the operating element. The AK rotary handle is lockable, so a maintenance technician can fit a padlock and keep the breaker open while working on the motor, which supports lockout practice at plants with strict isolation rules.
The handle is larger, so the device grows from 102.5 mm to 120 mm in height and from 0.42 kg to 0.425 kg in weight. Panel doors and cut-outs designed around the standard knob should be checked before substituting the AK version.
Where the PKE12/AK/XTU-12 is used
Plants with formal isolation procedures prefer breakers that can be locked: pump stations, compressor rooms, utility plant and machine lines operated by several shifts. In a motor starter the PKE12/AK/XTU-12 is placed ahead of a DILM contactor and covers motors of about 1.1 to 5.5 kW. For smaller motors the PKE12/XTU-4 is available with a standard knob, and for larger ones the PKE32/XTU-32.
Selection checklist for the PKE12/AK/XTU-12
- Confirm that the motor current falls inside 3 to 12 A.
- Check that lockout provisions require an AK lockable handle rather than a standard knob.
- Allow for the 120 mm device height in the enclosure.
- Select the trip class suited to the starting duty.
- Check the short-circuit level against manufacturer tables.
Installation and maintenance of the PKE12/AK/XTU-12
Mount the breaker on a 35 mm rail and wire conductors with ferrules to the screw terminals at 1.7 Nm. Set the dial and trip class on the trip block. Test the lock function with a padlock before putting the panel into service and include the lockout step in the maintenance procedure. Inspect the terminals at service intervals.
Typical applications in Oman and the GCC
Oil and gas, power and water utilities in Oman and the GCC commonly enforce lock-out procedures for rotating equipment, and a lockable breaker at the motor feeder makes that practical. Panels in the Gulf run warm, so the 40 °C enclosed rating should be checked as with every PKE device.
Eaton PKE family at a glance
| Model | Setting range | Notes |
|---|---|---|
| PKE12/XTU-1,2 | 0.3 – 1.2 A | Very small motors, 0.25 kW at 400 V |
| PKE12/XTU-4 | 1 – 4 A | Up to 1.5 kW at 400 V |
| PKE12/XTU-12 | 3 – 12 A | Up to 5.5 kW at 400 V |
| PKE12/AK/XTU-12 | 3 – 12 A | AK lockable rotary handle |
| PKE32/XTU-32 | 8 – 32 A | Up to 15 kW at 400 V |
| PKE-XTU-12 | 3 – 12 A | Trip block only, for PKE12 and PKE32 basic devices |
The table lists the PKE models covered on our pages. Basic device, trip block and handle options combine into the complete devices shown; confirm each combination from its own sheet.
Information to send with an RFQ for PKE12/AK/XTU-12
- Exact model PKE12/AK/XTU-12 (catalog number 158243) and the quantity, including spares.
- Motor nameplate data and trip class.
- Confirmation that the AK lockable handle is required.
- Door cut-out dimensions if the device replaces a standard knob version.
- Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
- Any documents you need with the quotation, such as an installation leaflet or declaration of conformity.
Documents and quotation
The manufacturer specification sheet for PKE12/AK/XTU-12 is attached on this page, so you can check the ratings, dimensions and approvals against your project before you order. Installation leaflets and declarations of conformity can be requested separately.
Seven Star LLC supplies Eaton industrial control products in Oman and the GCC. To request a quotation, send model PKE12/AK/XTU-12, the quantity and your delivery location, and we will confirm availability and lead time for your order.
Other Models in the Eaton Pke Range
Seven Star LLC supplies models from the Eaton Pke range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Eaton PKE12/XTU-12 Electronic Motor-Protective Breaker 3-12 A | Circuit Breakers | View details |
| Eaton PKE12/XTU-4 Electronic Motor-Protective Breaker 1-4 A | Circuit Breakers | View details |
| Eaton PKE12/XTU-1,2 Motor-Protective Breaker 0.3-1.2 A | Circuit Breakers | View details |
| Eaton PKE32/XTU-32 Electronic Motor-Protective Breaker 8-32 A | Circuit Breakers | View details |
| Eaton PKE12/AK/XTU-12 Motor-Protective Breaker with AK Handle | Circuit Breakers | You are viewing this model |
Datasheets & Documents
- Datasheet Eaton PKE12/AK/XTU-12 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.
Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.
Eaton company profile
| Founded | 1911, New York, USA, by Joseph O. Eaton |
|---|---|
| Early move | Cleveland, Ohio, 1914 |
| Headquarters | Dublin, Ireland, since the 2012 Cooper Industries acquisition |
| Listing | New York Stock Exchange (ETN) |
| Brands | Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC |
| Product families | FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling |
Milestones
- 1911: Joseph O. Eaton starts an axle business in New York.
- 1914: The business moves to Cleveland.
- 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.
Eaton circuit protection listed here
The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.
Where Eaton breakers and fuses are used
Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.
Eaton products we list
Ordering Eaton parts: what we need
Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.
Facts checked against Eaton's corporate history and investor materials, October 2026.
Browse Eaton products by category: Circuit Breaker.
FAQ
Questions about the Eaton PKE12/AK/XTU-12 Motor-Protective Breaker with
Answers from our engineering team on installation, compatibility and integration.
01What distinguishes the PKE12/AK/XTU-12 from the PKE12/XTU-12?
The electronic data is the same, but the PKE12/AK/XTU-12 has an AK lockable rotary handle instead of a standard knob, which makes it 120 mm high instead of 102.5 mm.
02What setting range does the PKE12/AK/XTU-12 have?
The trip block is adjustable from 3 A to 12 A with a rated operational current of 12 A. At 380/400 V and 50 Hz the rated power in AC-3e is 5.5 kW.
03Can the PKE12/AK/XTU-12 be locked in the off position?
The sheet describes the handle as an AK lockable rotary handle, so the breaker can be secured against switching on, which supports lockout during maintenance.
04What is the weight of the PKE12/AK/XTU-12?
The specification sheet gives 0.425 kg, with a depth of 101 mm, a height of 120 mm and a width of 45 mm.
05What protection functions does the PKE12/AK/XTU-12 provide?
Overload release, phase-failure sensitivity to IEC/EN 60947-4-1 and VDE 0660 part 102, and protection for heavy starting duty, with a fixed short-circuit release at 15.5 times the rated current.