Brand:

Eaton PL7-C16/1N MCB 16 A C-Curve Single-Pole Plus Neutral

Description

Eaton PL7-C16/1N miniature circuit breaker, 16 A, characteristic C

The Eaton PL7-C16/1N (catalog number 262749) is a 16 A breaker that protects the phase conductor and switches the neutral together with it. It is used on single-phase final circuits where the neutral also has to be disconnected, in 1.5 modules instead of two. It belongs to the Moeller xPole PL7 range and has tripping characteristic C, so it tolerates the inrush of lamps, small transformers and motors without nuisance trips while still disconnecting a short circuit within milliseconds. The rated breaking capacity is 10 kA according to IEC/EN 60898-1. Seven Star LLC supplies the PL7-C16/1N in Oman and the GCC.

How to read the model code PL7-C16/1N

PL7 is the series, C is the tripping characteristic, 16 is the rated current in amperes and the part after the slash gives the pole configuration: one protected pole plus a switched neutral, 16 A. Neighbouring models in the same family differ in rating, pole count and breaking capacity, and the 10 kA PL7 series sits above the 6 kA PL6 series.

PL7-C16/1N technical specifications

Parameter Specification
Manufacturer / part number Eaton PL7-C16/1N (catalog number 262749)
Series Eaton Moeller xPole PL7 miniature circuit breaker
Poles Single-pole plus neutral
Rated current In 16 A
Tripping characteristic C
Rated short-circuit breaking capacity Icn (IEC/EN 60898-1) 10 kA
Poles total / protected 2 / 1
Rated operational voltage Ue, max 230 V
Rated insulation voltage Ui 440 V
Rated impulse withstand voltage Uimp 4 kV
Frequency 50/60 Hz
Current limiting class 3
Width 26.4 mm (1.5 modular spacings)
Dimensions (depth x height x width) 71 x 82 x 26.4 mm
Weight 0.22 kg
Power loss 2.7 W
Ambient operating temperature -25 to 75 °C
Degree of protection IP20
Mounting DIN rail (EN/IEC 60715)
Overvoltage category / pollution degree III / 2

The data above follows the manufacturer specification sheet for catalog number 262749. Where a value is not listed for this exact part, it has been left out.

What characteristic C means for the PL7-C16/1N

Characteristic C is the general-purpose curve of IEC/EN 60898-1: the instantaneous magnetic release operates between five and ten times the rated current, while the thermal element protects against sustained overload. For a 16 A breaker that places the magnetic trip between 80 and 160 A. This curve suits installations with moderate inrush, which is the case for lighting, small motors and mixed loads. For very high inrush such as large transformers, a different characteristic may be needed.

Current limiting and coordination with upstream devices

The sheet for the PL7-C16/1N lists current limiting class 3. Class 3 is the highest energy-limiting class defined by IEC/EN 60898-1, which means the breaker lets through little energy during a short circuit and so protects cables and the busbar behind it. When this breaker is fed from a larger device, check the manufacturer coordination tables for back-up protection and discrimination, because the actual selectivity limit depends on the upstream device and on the fault current at the point of installation.

Selection checklist for the PL7-C16/1N

  • Check that the circuit load current is below 16 A, and that the cable cross-section is rated for at least 16 A.
  • Confirm that the prospective short-circuit current at the board is below the 10 kA breaking capacity.
  • Choose the pole configuration to match the circuit: one protected pole plus a switched neutral, 16 A.
  • Allow for the power loss of 2.7 W per breaker when you calculate board temperature.
  • Check the available width: 26.4 mm, which equals 1.5 modular spacings.

Installation and maintenance of the PL7-C16/1N

The breaker clips onto a 35 mm DIN rail and can be mounted in any position. Conductors from 1 to 25 mm² can be fitted into the screw terminals with pressure plate where the sheet lists them for this model; tighten them to the torque in the table. Operate the handle to check the on and off positions: the indicator shows red for on and green for off. After a trip, find the cause before switching on again. Test the handle action and check terminal tightness at scheduled board inspections.

Applications of the PL7-C16/1N in Oman and the GCC

Miniature circuit breakers like the PL7-C16/1N are used in distribution boards for buildings, utility rooms, control panels and light industrial machinery across Oman and the GCC. Boards in hot climates often run close to their temperature limit, so select the rating with allowance for derating and keep boards ventilated. Dust and humidity can affect terminals, so choose enclosures with a suitable IP rating.

Eaton xPole MCB range overview

Model Poles Rating Breaking capacity
PL6-C10/1 1 10 A 6 kA
PL6-C10/1N 1+N 10 A 6 kA
PL7-C10/1 1 10 A 10 kA
PL7-C16/1 1 16 A 10 kA
PL7-C16/1N 1+N 16 A 10 kA
PL7-C16/3 3 16 A 10 kA
PL7-C16/3N 3+N 16 A 10 kA

The table shows representative models; each has its own page with the sheet data. When ordering, quote the complete model code PL7-C16/1N so the correct pole count and rating are supplied.

Information to send with an RFQ for PL7-C16/1N

  • Exact model PL7-C16/1N (catalog number 262749) and the quantity, including spares.
  • Rated current, tripping characteristic and number of poles.
  • Prospective short-circuit current at the installation point.
  • Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
  • Any documents you need with the quotation, such as an installation leaflet or declaration of conformity.

Documents and quotation

The manufacturer specification sheet for PL7-C16/1N is attached on this page, so you can check the ratings, dimensions and approvals against your project before you order. Installation leaflets and declarations of conformity can be requested separately.

Seven Star LLC supplies Eaton industrial control products in Oman and the GCC. To request a quotation, send model PL7-C16/1N, the quantity and your delivery location, and we will confirm availability and lead time for your order.

Other Models in the Eaton Xpole Mcb Range

Seven Star LLC supplies models from the Eaton Xpole Mcb range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Eaton PL7-C10/1 MCB 10 A C-Curve Single-PoleCircuit BreakersView details
Eaton PL7-C16/1 MCB 16 A C-Curve Single-PoleCircuit BreakersView details
Eaton PL7-C16/1N MCB 16 A C-Curve Single-Pole Plus NeutralCircuit BreakersYou are viewing this model
Eaton PL7-C16/3 MCB 16 A C-Curve Three-PoleCircuit BreakersView details
Eaton PL7-C16/3N MCB 16 A C-Curve Three-Pole Plus NeutralCircuit BreakersView details
Eaton PL6-C10/1 MCB 10 A C-Curve Single-PoleCircuit BreakersView details
Eaton PL6-C10/1N MCB 10 A C-Curve Single-Pole Plus NeutralCircuit BreakersView details
Datasheets & Documents
  • PDF Datasheet Eaton PL7-C16/1N Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.

Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.

Eaton company profile

Founded 1911, New York, USA, by Joseph O. Eaton
Early move Cleveland, Ohio, 1914
Headquarters Dublin, Ireland, since the 2012 Cooper Industries acquisition
Listing New York Stock Exchange (ETN)
Brands Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC
Product families FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling

Milestones

  • 1911: Joseph O. Eaton starts an axle business in New York.
  • 1914: The business moves to Cleveland.
  • 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.

Eaton circuit protection listed here

The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.

Where Eaton breakers and fuses are used

Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.

Eaton products we list

Family Examples
Circuit Breakers LPJ-35SP Class J Time-Delay Fuse, NZMN1-A80 Molded Case Circuit Breaker, NZMN2-A250 Molded Case Circuit Breaker, NZMN3-AE400 Molded Case Circuit Breaker, PKZM0-1
AC Drives DA1-342D2FB-A20C AC Drive, PowerXL DG1-34140FN-C21C Variable Freque…

Ordering Eaton parts: what we need

Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.

Facts checked against Eaton's corporate history and investor materials, October 2026.

FAQ

Questions about the Eaton PL7-C16/1N MCB 16 A C-Curve Single-Pole Plus

Answers from our engineering team on installation, compatibility and integration.

01What is the rated current of the PL7-C16/1N?
16 A with tripping characteristic C, as stated on the specification sheet for this catalog number.
02What is the breaking capacity of the PL7-C16/1N?
The rated short-circuit breaking capacity Icn is 10 kA according to IEC/EN 60898-1.
03How many poles does the PL7-C16/1N have?
It is a single-pole plus neutral breaker occupying 1.5 modular spacings, 26.4 mm wide.
04What size is the PL7-C16/1N?
The sheet gives 71 x 82 x 26.4 mm (depth x height x width) and a weight of 0.22 kg.
05How much power loss does the PL7-C16/1N have?
The sheet lists a power loss of 2.7 W per breaker at rated current.