Brand:

Eaton PKE12/XTU-4 Electronic Motor-Protective Breaker 1-4 A

Description

Eaton PKE12/XTU-4 electronic motor-protective circuit-breaker, 1–4 A

The Eaton PKE12/XTU-4 (catalog number 121732) is an electronic motor-protective circuit-breaker for small three-phase motors. It combines a PKE12 basic device with a standard turn knob and an XTU-4 electronic trip block, giving a setting range of 1 to 4 A and a rated power of 1.5 kW at 380/400 V, 50 Hz. At the low end of the PKE range, a narrow current window is valuable because the dial can be set close to the nameplate value of a small motor. Seven Star LLC supplies the PKE12/XTU-4 in Oman and the GCC for OEMs, panel builders and maintenance teams.

What the PKE12/XTU-4 code means

PKE12 is the basic device frame, 45 mm wide, while XTU-4 is the electronic trip block with a 4 A upper limit and a 1 A lower limit. Together they form the complete device 121732. For motors that draw less than 1 A the PKE12/XTU-1,2 covers 0.3 to 1.2 A, and for 3 to 12 A the PKE12/XTU-12 is the corresponding device. Because the trip block can be exchanged, the same basic device can be re-ranged when a motor is replaced.

PKE12/XTU-4 technical specifications

Parameter Specification
Manufacturer / part number Eaton PKE12/XTU-4 (catalog number 121732)
Series Eaton Moeller PKE
Product category Motor-protective circuit-breaker, electronic, three-pole
Rated operational voltage Ue 690 V, 50/60 Hz
Rated impulse withstand voltage Uimp 6000 V AC
Overvoltage category / pollution degree III / 3
Actuator Turn button
Functions Motor protection, overload release, protection for heavy starting duty, phase-failure sensitive
Short-circuit release Basic device fixed at 15.5 × Iu; trip block fixed at 15.5 × Ir, delayed approx. 60 ms (±20 %)
Setting range (overload release) 1 – 4 A
Rated operational current Ie / Iu 4 A / 4 A
Rated operational power AC-3e, 230 V / 400 V / 440 V, 50 Hz 0.75 kW / 1.5 kW / 1.5 kW
Rated operational power AC-3e, 500 V / 690 V, 50 Hz 2.2 kW / 3 kW
Heat dissipation, total / per pole 0.9 W / 0.3 W
Resistance per pole 10 mΩ
Dimensions (depth x height x width) 101 x 102.5 x 45 mm
Weight 0.42 kg
Compliance CE marked
Mechanical / electrical lifespan 50,000 operations each (electrical at 400 V, AC-3)
Operating frequency 60 operations per hour
Ambient operating temperature −25 to 55 °C open; −25 to 40 °C enclosed
Ambient storage temperature −40 to 80 °C
Temperature compensation −5 to 40 °C to IEC/EN 60947, operating range −25 to 55 °C
Degree of protection IP20; terminals IP00
Connection Screw terminals, 1 or 2 × 1–6 mm² with ferrule, AWG 14–10, 10 mm stripping, 1.7 Nm main / 1 Nm control
Mounting 35 mm top-hat rail

The sheet also lists assigned motor power for North American ratings at 60 Hz: 0.125 HP at 115/120 V and 0.33 HP at 230/240 V single-phase; 0.75 HP at 200/208 V and 230/240 V, 2 HP at 460/480 V and 3 HP at 575/600 V three-phase.

Why a 1 to 4 A window matters on the PKE12/XTU-4

Small motors are the hardest to protect accurately. A 0.37 kW motor draws under 1 A at 400 V, and a 1.5 kW motor about 3.5 A, so a breaker with a wide range puts the setting at the bottom of its scale where tolerance matters most. The PKE12/XTU-4 spans only 1 to 4 A, which means typical small motors fall in the middle of the dial. Electronic measurement of all three phases allows phase-failure and overload protection to IEC/EN 60947-4-1 at these low currents.

Rated operational power in AC-3e is 0.75 kW at 230 V, 1.5 kW at 380/400 V and 440 V, 2.2 kW at 500 V and 3 kW at 690 V. Heat dissipation is low, 0.9 W for the three poles at full current, which helps in crowded panels. The short-circuit release is fixed at 15.5 times the rated current, delayed about 60 ms on the trip block.

Where the PKE12/XTU-4 fits

The PKE12/XTU-4 is chosen for auxiliary drives: small pumps, conveyor motors, gate and door drives, fan units, dosing equipment and machine tool auxiliaries. In a motor starter it sits upstream of a small contactor. The sheet lists minimum current flow times for trip classes 5, 10, 15 and 20, so the class can be matched to the starting behaviour of the load, a feature a thermal breaker does not offer. For motors below 1 A, step down to the PKE12/XTU-1,2; for motors above 4 A and up to 12 A use the PKE12/XTU-12.

Choosing the PKE12/XTU-4

  • Confirm that the motor nameplate current at the supply voltage is between 1 and 4 A, ideally near the middle.
  • Pick the trip class for the starting duty of the load.
  • Check the supply voltage: the rated power drops to 0.75 kW at 230 V.
  • Check the short-circuit level against manufacturer tables for 400 V or 690 V use.
  • Consider the AK handle version family if padlocking is required.

Installation of the PKE12/XTU-4

Mount the PKE12/XTU-4 on a 35 mm rail and connect conductors with ferrules to the screw terminals at 1.7 Nm. Set the current dial to the motor nameplate value and select the trip class. Check the motor current at commissioning with a clamp meter. Inspect terminals at each service interval and keep the panel within the 40 °C enclosed limit.

Typical applications in Oman and the GCC

Small motors are everywhere in Gulf installations: dosing pumps in desalination, ventilation fans in utility buildings, valve actuators and conveyors in workshops. For such loads the PKE12/XTU-4 gives a precise setting in a compact 45 mm width, which is useful when many feeders share a panel in a hot room. Dust and humidity require sealed enclosures and sensible ventilation planning.

Eaton PKE family at a glance

Model Setting range Notes
PKE12/XTU-1,2 0.3 – 1.2 A Very small motors, 0.25 kW at 400 V
PKE12/XTU-4 1 – 4 A Up to 1.5 kW at 400 V
PKE12/XTU-12 3 – 12 A Up to 5.5 kW at 400 V
PKE12/AK/XTU-12 3 – 12 A AK lockable rotary handle
PKE32/XTU-32 8 – 32 A Up to 15 kW at 400 V
PKE-XTU-12 3 – 12 A Trip block only, for PKE12 and PKE32 basic devices

The table lists the PKE models covered on our pages. Basic device, trip block and handle options combine into the complete devices shown; confirm each combination from its own sheet.

Information to send with an RFQ for PKE12/XTU-4

  • Exact model PKE12/XTU-4 (catalog number 121732) and the quantity, including spares.
  • Motor nameplate current and voltage.
  • Required trip class and number of feeders.
  • Whether an AK lockable handle version is preferred.
  • Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
  • Any documents you need with the quotation, such as an installation leaflet or declaration of conformity.

Documents and quotation

The manufacturer specification sheet for PKE12/XTU-4 is attached on this page, so you can check the ratings, dimensions and approvals against your project before you order. Installation leaflets and declarations of conformity can be requested separately.

Seven Star LLC supplies Eaton industrial control products in Oman and the GCC. To request a quotation, send model PKE12/XTU-4, the quantity and your delivery location, and we will confirm availability and lead time for your order.

Other Models in the Eaton Pke Range

Seven Star LLC supplies models from the Eaton Pke range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Eaton PKE12/XTU-12 Electronic Motor-Protective Breaker 3-12 ACircuit BreakersView details
Eaton PKE12/XTU-4 Electronic Motor-Protective Breaker 1-4 ACircuit BreakersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Eaton PKE12/XTU-4 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.

Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.

Eaton company profile

Founded 1911, New York, USA, by Joseph O. Eaton
Early move Cleveland, Ohio, 1914
Headquarters Dublin, Ireland, since the 2012 Cooper Industries acquisition
Listing New York Stock Exchange (ETN)
Brands Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC
Product families FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling

Milestones

  • 1911: Joseph O. Eaton starts an axle business in New York.
  • 1914: The business moves to Cleveland.
  • 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.

Eaton circuit protection listed here

The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.

Where Eaton breakers and fuses are used

Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.

Eaton products we list

Family Examples
Circuit Breakers LPJ-35SP Class J Time-Delay Fuse, NZMN1-A80 Molded Case Circuit Breaker, NZMN2-A250 Molded Case Circuit Breaker, NZMN3-AE400 Molded Case Circuit Breaker, PKZM0-1
AC Drives DA1-342D2FB-A20C AC Drive, PowerXL DG1-34140FN-C21C Variable Freque…

Ordering Eaton parts: what we need

Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.

Facts checked against Eaton's corporate history and investor materials, October 2026.

FAQ

Questions about the Eaton PKE12/XTU-4 Electronic Motor-Protective

Answers from our engineering team on installation, compatibility and integration.

01What is the setting range of the PKE12/XTU-4?
The electronic trip block is adjustable from 1 A to 4 A with a rated operational current of 4 A. It is intended for small three-phase motors.
02What motor power does the PKE12/XTU-4 cover?
The rated operational power in AC-3e is 0.75 kW at 230 V, 1.5 kW at 380/400 V and 440 V, 2.2 kW at 500 V and 3 kW at 690 V, according to the specification sheet.
03How much heat does the PKE12/XTU-4 dissipate?
The sheet lists 0.9 W for the complete device at rated current, or 0.3 W per pole, with a resistance of 10 milliohm per pole.
04Which trip classes does the PKE12/XTU-4 support?
The sheet lists minimum current flow times for classes 5, 10, 15 and 20, so the trip block can be set to suit light or heavy starting duty.
05What are the dimensions of the PKE12/XTU-4?
It is 101 mm deep, 102.5 mm high and 45 mm wide and weighs 0.42 kg. It mounts on a 35 mm top-hat rail and is CE marked.