Brand: Advantech
Advantech ADAM-4019+ 8-Channel Universal Analog Input Module
Description
Overview
Advantech ADAM-4019+ is the universal member of the eight-channel ADAM-4000 analog input group. Where sister modules are specialised for volts and milliamps or for thermocouples, this one lets every channel be set to its own input type: thermocouple, millivolt, volt or milliamp. A single DIN-rail box can therefore read a K-type thermocouple on channel 0, a 4 to 20 mA transmitter on channel 1 and a plus or minus 10 V signal from a vibration or position device on channel 2, all reported to the host through Modbus RTU or ASCII commands on RS-485.
That flexibility is why Advantech ADAM-4019+ is a popular choice for retrofit cabinets and small skids where nobody wants to stock three different input modules. Seven Star LLC is an independent supplier serving Oman and the GCC.
Feature summary for Advantech ADAM-4019+
- Eight differential channels with independent configuration, so each point has its own type and range.
- Voltage ranges from 100 mV to 10 V in unipolar and bipolar form, plus 0 to 20 mA, 4 to 20 mA and plus or minus 20 mA current ranges.
- Thermocouple types J, K, T, E, R, S, B and N with burnout detection.
- Power draw of 1.0 W at 24 VDC from an unregulated 10 to 30 VDC supply.
- 3,000 VDC isolation and 16-bit resolution.
- Pluggable terminal blocks, two of them, taking 14 to 22 AWG wire.
Technical data of Advantech ADAM-4019+
| Model | ADAM-4019+ (ordering code ADAM-4019+-F) |
|---|---|
| Function | 8-channel universal analog input module with Modbus |
| Channels | 8 differential, individual input type per channel |
| Input types | Thermocouple, mV, V, mA |
| Voltage ranges | 0 to 100 mV, 0 to 500 mV, 0 to 1 V, 0 to 2.5 V, 0 to 5 V, 0 to 10 V and bipolar equivalents up to plus or minus 10 V |
| Current ranges | Plus or minus 20 mA, 0 to 20 mA, 4 to 20 mA |
| Input impedance | Voltage 20 megohm; current 120 ohm |
| Thermocouples | J 0 to 760, K 0 to 1,370, T minus 100 to 400, E 0 to 1,000, R and S 500 to 1,750, B 500 to 1,800, N minus 200 to 1,300 degrees Celsius |
| Resolution | 16-bit |
| Sampling | 10 samples per second, total |
| Accuracy | Voltage 0.1 percent or better, current 0.2 percent or better |
| Isolation | 3,000 VDC |
| Overvoltage protection | Plus or minus 35 VDC |
| Power | 10 to 30 VDC unregulated; 1.0 W at 24 VDC |
| Watchdog | System 1.6 second and communication |
| Operating temperature | minus 10 to 70 degrees Celsius |
| Storage temperature | minus 25 to 85 degrees Celsius |
One module for several signal types
The practical benefit appears during commissioning. Panel builders often receive a late change request: a pressure transmitter turns into a thermocouple, or a 0 to 5 V potentiometer feedback must be added. With the ADAM-4019+ the change is a configuration command, not a hardware swap. The front label of the module lists code numbers for each range, from 00 upward, and the user sets them per channel with the configuration utility. Remember that all eight channels share the 10 sample per second budget, so a fast loop should live on a dedicated module.
Applications for ADAM-4019+ in Oman and the GCC
Skid-mounted packages for water treatment, small gas compressors, and utility monitoring cabinets often carry a mixed bag of signals. Laboratories and test rigs use this module to log thermocouples alongside strain-bridge amplifier outputs. In building services, it can gather temperatures and 4 to 20 mA values into one Modbus network for a BMS gateway.
Configuring channels and reading values
Configuration is carried out over the same RS-485 line used for operation. The user connects the module through a converter, starts the Advantech utility, selects the module address, baud rate and checksum option, and then walks through channels one at a time to assign range codes. After the setup is saved in the module it survives a power cycle. In operation, a Modbus master reads the eight input registers as engineering values; for thermocouple channels the value is a temperature, for voltage channels it is a voltage scaled to the selected range, and for current channels it is a milliamp reading. The 1.6 second watchdog protects against a stalled processor or a lost host, and the module recovers on its own after a watchdog event.
Protection, isolation and noise behaviour
The ADAM-4019+ carries 3,000 VDC isolation between the field side and the logic, with built-in TVS and ESD protection, and tolerates plus or minus 35 VDC at the inputs. Isolation matters in plants where grounded thermocouples, welded instruments and variable speed drives create ground potential differences. A module without isolation can show drifting readings or fail outright in such places. With 16-bit resolution on the selected range, a 0 to 10 V span resolves finer than a typical transmitter can repeat, so the overall accuracy figure of 0.1 percent for voltage and 0.2 percent for current is what matters for system budgeting.
Choosing ranges sensibly
Pick the narrowest range that covers the signal, because resolution is spread across the full span. A 4 to 20 mA loop belongs on the 4 to 20 mA range, not on the 0 to 20 mA range, so that a broken wire shows as a value below 4 mA. For thermocouples, choose the correct type code; a K-type probe configured as J gives a plausible but wrong temperature.
How ADAM-4019+ differs from ADAM-4017+ and ADAM-4018+
The ADAM-4017+ handles millivolt, volt and milliamp only and draws 1.2 W. The ADAM-4018+ handles thermocouples and current only at 0.8 W. The ADAM-4019+ merges the capabilities, accepts both thermocouple and voltage inputs, and sits at 1.0 W. Its voltage list includes a 2.5 V range that is not offered on the ADAM-4017+ list.
Installation and maintenance
Mount on a rail, supply 10 to 30 VDC, connect the RS-485 pair, then configure each channel. Verify with a calibrator on each type you use. Check terminals and shielding at routine services.
Ordering notes
List which signal types you plan to connect and the quantity of Advantech ADAM-4019+. The ordering code printed by the manufacturer is ADAM-4019+-F.
Related items you may also need: Advantech ADAM-4150 Robust 15-Channel Digital I/O Module with Modbus | Advantech ADAM-6050 12DI/6DO Ethernet Digital I/O Module | Advantech ADAM-4017+ 8-Channel Analog Input Module RS-485 | All Advantech products.
Documents and quotation
The datasheet attached to this page is the manufacturer document shared by the ADAM-4017+, ADAM-4018+ and ADAM-4019+ modules. Send an RFQ with the part number Advantech ADAM-4019+ and the quantity.
Datasheets & Documents
- Datasheet Advantech ADAM-4019+ 8-Channel Universal Analog Input Module Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Advantech is the Taiwanese maker of industrial computers and IoT hardware: ADAM remote I/O modules, EKI industrial Ethernet switches and serial device servers, industrial PCs, panel PCs and embedded boards. It was founded in Taipei in 1983 by K.C. Liu and partners, and today Advantech Co., Ltd. is headquartered in Taipei and listed on the Taiwan Stock Exchange.
Seven Star LLC supplies Advantech automation products to system integrators and plant teams in Oman, and this page lists items such as an ADAM-6000 Ethernet I/O module, an ADAM-4000 serial converter and an IPC rackmount chassis.
Advantech company profile
| Founded | 1983, Taipei, Taiwan |
|---|---|
| Founder | K.C. Liu and partners |
| Headquarters | Taipei, Taiwan |
| Ownership | Advantech Co., Ltd., public company listed on the Taiwan Stock Exchange |
| Product families | ADAM-4000 and ADAM-6000 remote I/O, EKI managed and unmanaged switches and serial device servers, industrial PCs and rackmount computers, panel PCs, embedded boards and edge gateways |
Advantech ADAM and IPC products listed here
The ADAM-6017 is an 8-channel analog input module from the ADAM-6000 Ethernet I/O family. It brings voltage and current signals onto a network and is read by SCADA or PLC software over Modbus TCP. The ADAM-4520 belongs to the ADAM-4000 serial family and converts RS-232 to isolated RS-422 or RS-485, a common fix for linking a PC or panel to field devices. The IPC-623 is a 4U, 20-slot rackmount chassis that houses a backplane, CPU card and expansion cards for control room computers.
Advantech products we list
Ordering Advantech hardware: what we need
Send the full part number with its suffix. Advantech adds letters after the model, as in ADAM-6017-D, to mark the hardware revision, and existing configurations sometimes depend on it. For an IPC chassis, state the backplane, power supply and drive bay arrangement, since these are ordered as specific versions. We supply across the GCC and check part numbers against Advantech documentation.
Facts checked against Advantech's published corporate profile, October 2026.
Browse Advantech products by category: Industrial Computer, PLC & I/O Cards, Industrial Communications.
FAQ
Questions about the Advantech ADAM-4019+ 8-Channel Universal Analog
Answers from our engineering team on installation, compatibility and integration.
01What makes the Advantech ADAM-4019+ universal?
Each of its 8 differential channels can be set to its own input type: thermocouple, millivolt, volt or milliamp.
02What power does the ADAM-4019+ consume?
The datasheet gives 1.0 W at 24 VDC from an unregulated 10 to 30 VDC supply.
03Which current ranges does the ADAM-4019+ accept?
It accepts plus or minus 20 mA, 0 to 20 mA and 4 to 20 mA, using a 120 ohm current input impedance.
04How does the ADAM-4019+ compare with the ADAM-4018+?
The ADAM-4018+ is limited to thermocouples and current at 0.8 W; the ADAM-4019+ adds voltage inputs and draws 1.0 W.
05What protocols does the ADAM-4019+ support?
ASCII command and Modbus RTU over RS-485, with a 1.6 second system and communication watchdog.