Hydac HDA 47FG-A-0200-DV-000 Flameproof Transmitter, Flying Leads
Description
HDA 47FG-A-0200-DV-000 is the Hydac flameproof 200 psi pressure transmitter delivered with a factory-fitted cable running out of the conduit connection. The cable ends in open wires, which saves terminating single cores inside the junction box. The instrument is a gauge transmitter with a 4 to 20 mA output and a female 1/4-18 NPT process port. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Overview of HDA 47FG-A-0200-DV-000
This part number combines three decisions that are fixed at the factory: female pipe thread, flying leads and a 200 psi span. Many installers prefer the G type because the white and brown cores are already marked for loop connection and the conduit can be sealed once. The 0200 range is not one of the pre-listed breakpoints in the printed table of the family, yet the catalog record of HDA 47FG-A-0200-DV-000 gives its own overload, burst and maximum pressure.
Features of HDA 47FG-A-0200-DV-000
- Open-ended cable: white signal plus, brown signal minus, green and yellow unused.
- Two-wire current output with load limit (UB – 8 V) / 20 mA.
- Triple approval, ATEX KEMA 10ATEX100 X, CSA MC 224264, IECEx KEM 10.0053X.
- Overload 1160 psi, burst 2900 psi, operating pressure 200 psi.
- 1/4-18 NPT female port tightened to 40 N·m.
- Weight 0.661 lb, IP 65 in the vented gauge version.
Technical specifications table for HDA 47FG-A-0200-DV-000
| Parameter | Value |
|---|---|
| Model code | HDA 47FG-A-0200-DV-000 |
| Material number (catalog) | 923024 |
| Measuring range | 0 to 200 psi |
| Overload pressure | 1160 psi |
| Burst pressure | 2900 psi |
| Cell type | Vented gauge (V) |
| Process connection | 1/4-18 NPT, female |
| Tightening torque | 30 lb-ft (40 N·m) |
| Electrical connection | 1/2-14 NPT conduit, open-ended cable (flying leads) |
| Cores / cable | 72 in. cable per catalog code; white signal plus, brown signal minus, green and yellow not used |
| Output | 4 to 20 mA, 2-wire, load RLmax = (UB – 8 V) / 20 mA in kOhm |
| Supply voltage | 8 to 30 V DC, residual ripple 5 percent or less, about 25 mA |
| Accuracy (terminal based) | 0.25 percent FS typical and maximum; best-fit line 0.15 percent typical |
| Non-linearity / hysteresis / repeatability | 0.3 / 0.1 / 0.05 percent FS maximum |
| Temperature coefficient (zero, span) | 0.008 percent FS per degC typical, 0.015 maximum |
| Rise time / long-term drift | 1.5 ms or less / 0.1 percent FS per year |
| Wetted parts | Stainless steel 1.4542, 1.4571, 1.4435, 1.4404, 1.4301; FKM seal |
| Housing / conduit | 1.4404 and 1.4435 (316L) |
| Compensated temperature | T5 / T130: -13 to 176 degF; T6 / T110: -13 to 140 degF |
| Operating and fluid temperature | T5: -4 to 176 degF; T6: -4 to 140 degF (FKM seal) |
| Storage temperature | -40 to 212 degF |
| Protection | IP 65 (vented gauge) |
| Vibration | 20 g, 10 to 500 Hz |
| Weight | 0.661 lb (about 300 g) |
| Approvals | ATEX KEMA 10ATEX100 X; CSA MC 224264; IECEx KEM 10.0053X |
Field uses
The unit is typical on small hydraulic presses in mines, tensioning circuits on conveyors and pilot-gas supply lines on wellhead platforms. Where an Omani EPC wants one transmitter model on skids that carry different hazardous classifications, HDA 47FG-A-0200-DV-000 solves the approvals question at once, since CSA, ATEX and IECEx are all on the nameplate.
How HDA 47FG-A-0200-DV-000 differs from its relatives
The nearest sibling is 47F9, which has the same female thread but single cores. Next is 478G-A-0200, which has the same flying leads and 200 psi span but a male 1/4 NPT port. Against 47FG-A-0200 the 478G unit can be screwed into a female port. Neither differs in accuracy, which stays at 0.25 percent of full scale, nor in weight.
Choosing the right unit
Check the process stub first: HDA 47FG-A-0200-DV-000 needs a male thread. Then confirm the cable length in the catalog code, since the item here is shown with 72 inches. Choose a higher range if the line pulses above about 1000 psi, because the overload reserve is only 1160 psi.
Installation and loop check
Apply sealant, torque to 40 N·m on the hex, route the cable to a certified box and connect white and brown to the loop. Power from 8 to 30 V DC and confirm 4 mA at atmospheric pressure. At 200 psi the loop should show 20 mA. Record the serial number against the tag of HDA 47FG-A-0200-DV-000.
Maintenance
Inspect the cable jacket for abrasion and keep the conduit joint sealed. The sensor is rated above 10 million cycles. If HDA 47FG-A-0200-DV-000 fails a zero check, replace it rather than attempting repair in the field.
Customers frequently need the cable version when the original instrument had a hard-wired lead. Quote HDA 47FG-A-0200-DV-000 exactly, because the letters F and G change the process port and the wiring respectively.
Documentation and Compliance
Industrial buyers often need more than the hardware. When you order the Hydac HDA 47FG-A-0200-DV-000, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Hydac pressure transmitters items can be checked against the bill of materials quickly.
Frequently asked questions about HDA 47FG-A-0200-DV-000
What is special about the G in HDA 47FG-A-0200-DV-000? G marks a 1/2-14 NPT conduit thread with flying leads, in which the cable is attached by the manufacturer. The 9 variant uses single cores instead.
Which colours carry the signal on this version? White is signal plus and brown is signal minus. Green and yellow are not used on the 47FG family.
What are the overload and burst figures at 200 psi? The catalog lists 1160 psi overload pressure and 2900 psi burst pressure for HDA 47FG-A-0200-DV-000.
Is it suitable for dust atmospheres? The marking includes II 2D Ex tb IIIC T110 to 130 degC Db, together with the gas marks, so dust zones are covered subject to installation rules.
How can I request it? Send part number HDA 47FG-A-0200-DV-000 and quantity by RFQ to Seven Star LLC with the delivery destination.
Documents and quotation
The datasheet of HDA 47FG-A-0200-DV-000 is attached to this page. Please send your RFQ with the part number, quantity and delivery site and we will confirm lead time and documentation.
Other Models in the HDA 4700 ExD Range
Seven Star LLC supplies models from the HDA 4700 ExD range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Hydac HDA 478G-A-0200-DV-000 Ex d Transmitter, 1/4 NPT Male | Pressure Transmitters | View details |
| Hydac HDA 478G-A-0300-DV-000 Flameproof Transmitter 300 psi | Pressure Transmitters | View details |
| Hydac HDA 47FG-A-0200-DV-000 Flameproof Transmitter, Flying Leads | Pressure Transmitters | You are viewing this model |
| Hydac HDA 477G-A-0300-DV-000 SAE-6 Flameproof Transmitter | Pressure Transmitters | View details |
Datasheets & Documents
- Datasheet Hydac HDA 47FG-A-0200-DV-000 Flameproof Transmitter, Flying Leads Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac HDA 47FG-A-0200-DV-000 Flameproof
Answers from our engineering team on installation, compatibility and integration.
01What is special about the G in HDA 47FG-A-0200-DV-000?
G marks a 1/2-14 NPT conduit thread with flying leads, in which the cable is attached by the manufacturer. The 9 variant uses single cores instead.
02Which colours carry the signal on this version?
White is signal plus and brown is signal minus. Green and yellow are not used on the 47FG family.
03What are the overload and burst figures at 200 psi?
The catalog lists 1160 psi overload pressure and 2900 psi burst pressure for HDA 47FG-A-0200-DV-000.
04Is it suitable for dust atmospheres?
The marking includes II 2D Ex tb IIIC T110 to 130 degC Db, together with the gas marks, so dust zones are covered subject to installation rules.
05How can I request it?
Send part number HDA 47FG-A-0200-DV-000 and quantity by RFQ to Seven Star LLC with the delivery destination.