Description

For 3000 psi hydraulic circuits in explosion-risk zones, EDS 44F9-3000-1P-DS-000 is the reference part: a programmable switch with a single PNP output, built in a flameproof stainless body and ready for mining, gas and dust classifications. Its female 1/4-18 NPT process port pairs with a male stub, and the conduit thread is 1/2-14 NPT. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

At a glance: EDS 44F9-3000-1P-DS-000

At 3000 psi the sealed gauge cell offers an overload of 7250 psi and a burst of 14500 psi, so line spikes of more than twice the setpoint are survivable. The accuracy is 1 percent of full scale at most, the response time is 8 ms and the output can switch up to 1.2 A. Settings are entered with the HPG 3000 programmer in steps of 5 psi.

A note on the interpretation of the overload figures: 7250 psi is the pressure the cell survives without any change of its characteristics, while 14500 psi is the destructive limit. A control engineer who sets the pump relief at 3300 psi and trips this switch at 3000 psi still leaves more than double the reserve for pressure spikes. The accuracy limit of 1 percent equals 30 psi at full scale, so a trip point should not be placed so close to the relief setting that this tolerance plus the 5 psi grid could swallow the margin.

Features

  • Range 0 to 3000 psi, sealed gauge cell, IP 69K.
  • 1 PNP output; direction N/O or N/C is programmable.
  • On and off delay times from 8 to 2000 ms.
  • Weight 0.661 lb; supply 12 to 30 V DC.
  • Operating temperature -40 to 176 degF at T5, -40 to 140 degF at T6.
  • Approvals: ATEX KEMA 10ATEX100 X, CSA MC 224264, IECEx KEM 10.0053X.

Technical table, EDS 44F9-3000-1P-DS-000

Parameter Value
Model code EDS 44F9-3000-1P-DS-000
Material number (catalog) 921935
Setting range 0 to 3000 psi
Overload pressure 7250 psi
Burst pressure 14500 psi
Cell type Sealed gauge (S)
Process connection 1/4-18 NPT, female
Tightening torque 40 N·m (30 lb-ft)
Switching outputs 1 PNP, programmable
Output load max. 1.2 A
Switch-point increment 5 psi
Switch point / hysteresis window 5 to 100 percent / 1 to 96 percent of range
Switching delay 8 to 2000 ms via HPG 3000 programming unit
Response time 8 ms
Accuracy 1 percent FS maximum (0.5 percent typical)
Repeatability 0.1 percent FS maximum
Supply voltage 12 to 30 V DC, ripple 5 percent or less
Current consumption 25 mA plus switching current, 1.225 A total maximum
Electrical connection 1/2-14 NPT conduit, flying leads
Core assignment red +UB, white switch output 1, black 0 V, green SDA (programming), brown not used
Switching cycles more than 100 million
Compensated temperature T5 / T130: -13 to 176 degF; T6 / T110: -13 to 140 degF
Storage temperature -40 to 212 degF
Protection IP 69K (sealed gauge)
Vibration 20 g, 10 to 500 Hz
Weight 0.661 lb (about 300 g)
Approvals ATEX KEMA 10ATEX100 X; CSA MC 224264; IECEx KEM 10.0053X

Use cases

Examples: high-pressure hydraulic power units on drill drives, accumulator pre-charge supervision on blow-out preventer panels, clamping pressure monitoring on presses in hazardous workshops. In these places EDS 44F9-3000-1P-DS-000 saves a gauge, a transmitter and a relay.

How EDS 44F9-3000-1P-DS-000 differs from siblings

Against 44F9-0500-1P the range grows six times and the burst pressure rises from 2900 to 14500 psi. Against 44F9-6000-1P the range halves and the burst falls from 29000 to 14500 psi. The 4479-3000-2P has the same 3000 psi span, overload and burst, but adds a second PNP output rated 1 A and uses an SAE-6 male port at 20 N·m instead of NPT female at 40 N·m.

Selecting and wiring

Use EDS 44F9-3000-1P-DS-000 when one switching function is enough. For a pre-alarm and a trip together, choose the 2P type. Keep the programming line away from the load wire in the cable run, and supply from 12 to 30 V DC. Match the output to a PNP-compatible input of the PLC.

Installation

Wrap the pipe thread, tighten to 40 N·m on the hex and mount the conduit away from vibration above 20 g. After wiring, connect the HPG 3000 to the green and 0 V cores, set the point, and test at the actual working pressure of EDS 44F9-3000-1P-DS-000.

Maintenance

No adjustment screws exist, so mechanical drift is not a concern. Document the stored set points, check yearly and replace the unit if the 1 percent accuracy limit is exceeded.

For documentation, note that the marking set of this switch (I M2 Ex d I Mb, II 2G Ex d IIC T6 or T5 Gb, II 2D Ex tb IIIC T110 to 130 degC Db) is matched with the temperature class, so the T6 limit of 140 degF ambient and fluid applies wherever the hot-surface class must stay at T6. Record this class in the equipment register together with the programmed set points of the unit.

Frequently asked questions about EDS 44F9-3000-1P-DS-000

What is the working range of EDS 44F9-3000-1P-DS-000? 0 to 3000 psi, with 7250 psi overload and 14500 psi burst pressure.

What increment can the switch point be moved in? 5 psi, according to the catalog record for this range.

Does it carry two switching outputs? No. The 1P in the code means one output; two outputs would be 2P, as in the EDS 4479-3000-2P-DS-000.

What wiring does the flying lead use? Red +UB, white switch output 1, black 0 V, green programming line, brown unused.

How can I order it? Send an RFQ naming EDS 44F9-3000-1P-DS-000 and the quantity to Seven Star LLC.

Documents and quotation

The datasheet for EDS 44F9-3000-1P-DS-000 is attached. Send an RFQ with EDS 44F9-3000-1P-DS-000, quantity and delivery location for a quotation.

Other Models in the EDS 4400 ExD Range

Seven Star LLC supplies models from the EDS 4400 ExD range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hydac EDS 4479-3000-2P-DS-000 Two-Output Flameproof Pressure SwitchPressure SwitchesView details
Hydac EDS 44F9-6000-1P-DS-000 High-Pressure Ex d Switch 6000 psiPressure SwitchesView details
Hydac EDS 44F9-3000-1P-DS-000 Programmable Ex d Pressure SwitchPressure SwitchesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Hydac EDS 44F9-3000-1P-DS-000 Programmable Ex d Pressure Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac EDS 44F9-3000-1P-DS-000 Programmable Ex d

Answers from our engineering team on installation, compatibility and integration.

01What is the working range of EDS 44F9-3000-1P-DS-000?
0 to 3000 psi, with 7250 psi overload and 14500 psi burst pressure.
02What increment can the switch point be moved in?
5 psi, according to the catalog record for this range.
03Does it carry two switching outputs?
No. The 1P in the code means one output; two outputs would be 2P, as in the EDS 4479-3000-2P-DS-000.
04What wiring does the flying lead use?
Red +UB, white switch output 1, black 0 V, green programming line, brown unused.
05How can I order it?
Send an RFQ naming EDS 44F9-3000-1P-DS-000 and the quantity to Seven Star LLC.