Brand:

Panametrics XMTCpro Thermal Conductivity Binary Gas Analyzer

Description

XMTCpro thermal conductivity binary gas analyzer

The Panametrics XMTCpro is a compact, rugged thermal conductivity transmitter for continuous measurement of gas concentration in binary mixtures, such as hydrogen, carbon dioxide, methane or helium in a background gas. It works by comparing the thermal conductivity of the sample against that of a background gas: hydrogen, for example, conducts heat 6.80 times better than air (taken as 1.00), helium 5.53, methane 1.45 and carbon dioxide only 0.70. Panametrics calls it SIL 2 by design, and it comes with an integrated high-contrast multiparameter display, Modbus communication and a computer-enhanced signal measurement that gives fast response and real-time error detection. The measuring cell has no moving parts, so the XMTCpro tolerates vibration, shock and rough industrial environments.

Why plants specify the XMTCpro

  • Ultra-stable thermal conductivity sensor, described by the manufacturer as the most stable on the market, resistant to contamination and insensitive to flow variations.
  • Modular construction: the plug-in measuring cell can be replaced with a pre-calibrated spare in minutes, and field calibration is quick.
  • Optional functional safety to IEC 61508 SIL 2.
  • Measurement ranges from 0 to 1 percent through 0 to 100 percent, and high-end spans such as 90 to 100, 95 to 100 and 98 to 100 percent for purity monitoring.
  • Four measurement or alarm relays and two solenoid valve relays for sample system control.
  • Hazardous-area certification worldwide: IECEx, ATEX and NEC/CEC.

XMTCpro technical specifications

Parameter XMTCpro
Accuracy Plus or minus 2% of span (depends on gases and ranges)
Linearity / repeatability Plus or minus 1% of span / plus or minus 0.5% of span
Zero and span stability Plus or minus 0.5% of span per week (1% for the 0 to 1% range)
Response time 20 seconds for a 90% step change
Outputs Two isolated 4-20 mA, 550 ohm maximum, field programmable; Modbus RS232/RS485
Power 24 VDC plus or minus 4 VDC, 0.8 A
Sample flow 50 to 2,000 cc/min (0.1 to 4.0 SCFH); 250 cc/min nominal
Operating temperature -20 to 50 C standard; -5 to 65 C high-temperature version
Wetted materials 316 stainless steel, glass and Viton O-rings; optional Hastelloy C276 and Chemraz
Dimensions and weight Aluminum 228 x 178 x 142 mm, 4.5 kg; stainless steel 11.0 kg
Connections 3/4 in NPT electrical; 1/4 in NPTF sample inlet and outlet, with flame arrestors
Protection IP66, Type 4X; IECEx Ex db IIC T6 Gb, Ex tb IIIC T78 C Db; ATEX II 2 GD; Class I, II, III Div 1

Typical gas pairs and industries

The datasheet gives typical combinations of hydrogen in nitrogen, air, oxygen or carbon dioxide; helium in nitrogen or air; carbon dioxide in nitrogen or air; sulfur dioxide in air; argon in nitrogen or air; and the hydrogen, carbon dioxide and air mixture in hydrogen-cooled generators. Applications span the hydrogen value chain, heat-treating furnaces in the metals industry, generator cooling in power plants, hydrogen in hydrocarbon streams in refineries, ammonia, methanol and chlorine plants, carbon dioxide in methane and biogas, purity monitoring of argon, hydrogen, nitrogen and helium, and carbon dioxide in fermentation.

Selecting an XMTCpro for your sample gas

Because thermal conductivity is a bulk property, the analyzer needs a binary mixture or a mixture in which only one component varies. A clean, representative sample at controlled temperature, pressure and flow is essential, which is why Panametrics also offers sample systems and application engineering help. The ambient rating (standard or high-temperature) must match the installation, and the optional wetted-material upgrade to Hastelloy C276 and Chemraz O-rings suits corrosive streams such as chlorine plants.

The relative thermal conductivity table in the datasheet, referenced to air at 1.00 and measured at 100 C, is a quick feasibility check. Hydrogen at 6.80 and helium at 5.53 stand far above air, neon is 1.84, methane 1.45 and acetylene 0.90, while argon at 0.67, carbon dioxide at 0.70, n-butane at 0.74, water vapour at 0.77, sulfur dioxide at 0.38 and chlorine at 0.34 sit below it. The wider the gap between the gas of interest and the background gas, the better the sensitivity of the measurement; hydrogen in nitrogen is therefore easy, while a pair with similar conductivity, such as nitrogen and carbon monoxide, is a poor candidate. Water vapour and other condensable components also change the reading, so the sample conditioning should remove or control moisture.

When choosing the range, remember that a narrower span gives finer resolution but the stated stability and accuracy are expressed as a percentage of span, with the 0 to 1 percent range carrying a looser 1 percent weekly drift allowance. For purity applications such as 98 to 100 percent hydrogen cooling gas, the suppressed-zero ranges give a far better view of small changes than a 0 to 100 percent span. The high-temperature option extends the ambient window to 65 C, which can matter on sun-exposed skids in the Gulf summer.

Applications in Oman and GCC industry

Hydrogen-cooled generators at power stations, hydrogen purity in refinery hydrotreaters, nitrogen or argon purity at industrial gas plants, and biogas carbon dioxide and methane monitoring at wastewater treatment works are all relevant to the region. The hydrogen economy projects emerging in the GCC also create demand for hydrogen concentration monitors along the value chain.

Installation and servicing

Mount the analyzer close to the sample tap, connect the sample inlet and outlet to the 1/4 in NPTF ports, and make up the 24 VDC and signal wiring through the 3/4 in NPT entries. Use the magnetic keypad to configure range and alarms without removing covers, and field-calibrate with span and zero gases. If maintenance is needed, replace the plug-in cell with a pre-calibrated spare.

Supplier note

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We can discuss ranges, gas pairs and spare cells.

Documents and quotation

The manufacturer datasheet for XMTCpro is provided. In your RFQ state XMTCpro, the gas pair and measuring range, housing material, temperature class, safety options and quantity.

Datasheets & Documents
  • PDF Datasheet Panametrics XMTCpro Thermal Conductivity Binary Gas Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics XMTCpro Thermal Conductivity Binary Gas

Answers from our engineering team on installation, compatibility and integration.

01What does the XMTCpro measure?
Gas concentration in binary mixtures using thermal conductivity, for example hydrogen, carbon dioxide, methane or helium in a background gas.
02How fast does XMTCpro respond?
The datasheet states 20 seconds for a 90 percent step change.
03Does XMTCpro have a safety rating?
It is described as SIL 2 by design, and IEC 61508 SIL 2 functional safety is an option.
04How is an XMTCpro cell replaced?
The plug-in measuring cell can be swapped for a pre-calibrated spare in minutes, and field calibration is also possible.
05What sample flow does XMTCpro need?
50 to 2,000 cc/min (0.1 to 4.0 SCFH), with 250 cc/min (0.5 SCFH) as nominal.