Brand: Moore Industries
Moore Industries TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] Transmitter
Description
Moore Industries TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] in plain terms
Moore Industries TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] is the display version of the second-generation Smart HART temperature transmitter, delivered inside an aluminum explosion-proof BH enclosure with two NPT entries and a glass window. The P at the end of the housing code means a base plate and U-bolts are included, so the case can be fastened to a 2-inch pipe straight from the box.
Compared with the THZ2 family, the TDZ2 adds an integral two-row LCD and drops the connection-head option: it is a complete field instrument, not an insert for a head.
A practical reason to choose this exact code is the base plate: replacing a failed transmitter on a stanchion where U-bolts already exist is faster than building a bracket. The glass cover also means the operator sees the reading without removing any cover, which is the main reason a TDZ2 is chosen over a blind transmitter in a head.
What TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] brings to the loop
- Integral display: 10 mm digits for the measured value and 6 mm digits for status, with automatic decimal point from one to three places.
- The same universal input and total sensor diagnostics as the THZ2 module.
- Immunity of 20 V/m when tested to IEC 61326, higher than the 10 V/m of a THZ2 puck module.
- Start-up in under half a second and a 256 ms typical response.
- Display range of -99999 to 99999 with a minimum display span of 1.00.
These attributes make the TDZ2 a convenient local indicator for the operator and a HART-enabled transmitter for the maintenance team.
Data for TDZ2/TPRG/4-20MA/12-42DC [BH2NGP]
The table lists values for the TDZ2 in the BH housing.
| Parameter | Value for TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] |
|---|---|
| Model code | TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] |
| Unit | TDZ2 Smart HART temperature transmitter with integral display |
| Input | TPRG: RTD 2-, 3-, 4-wire Pt, Cu, Ni; thermocouple J, K, E, T, R, S, B, N, C; 0 to 4000 ohm; -50 to 1000 mV; potentiometer |
| Output | 4-20 mA with HART; address 0 to 15 |
| Supply | 12-42 V DC; 12-30 V DC for I.S. approval |
| Housing | BH2NGP: aluminum explosion-proof, two 1/2-inch NPT entries, glass cover, 2-inch pipe-mount base plate and U-bolts |
| Display | Top row 10 mm digits, bottom row 6 mm digits, HART address |
| Isolation | 500 Vrms input to output; 500 Vac dielectric test for 1 minute |
| Step response | 500 ms maximum, 256 ms typical |
| Analog output accuracy | Plus or minus 0.01% of maximum span |
| Weight (HP module in BH) | 1.4 kg (50.2 oz) |
| Other TDZ2 weights | HP 182 g; D-BOX 672 g; SB stainless 3.2 kg |
| RFI/EMI | 20 V/m when tested to IEC 61326, 0.5% of span or less error |
| Ambient | -40 to +85 C; 0 to 95% RH |
| Hazardous-area (BH) | FM explosion-proof Class I Div 1 Groups A*, B, C, D, Type 4X, IP66, T6 at 60 C |
| Start-up | Less than 0.5 s |
Use the table to compare against any older TDZ or TDZ2 you may be replacing. If the installed unit has a different entry code, for example BH2TG for 3/4-inch NPT, the new enclosure will not match the conduit unless adapters are used, and that can change the explosion-proof rating.
TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] compared with other TDZ2 and THZ2 versions
The same TDZ2 electronics can be obtained in an HP puck (182 g), a D-BOX (672 g) or a stainless SB enclosure (3.2 kg). The BH case sits in the middle at 1.4 kg and is a cast aluminum flameproof body. The THZ2 does not include a display at all, except when combined with a TDZ2-style module.
The isolation is 500 Vrms, lower than the 1500 Vrms quoted for the THZ2 HPP puck.
Use cases for TDZ2/TPRG/4-20MA/12-42DC [BH2NGP]
Common sites include hydrocarbon storage terminals, pump stations, steam headers and chemical dosing skids. The display allows local verification of the loop reading during maintenance rounds, which is useful where hand-held communicators are restricted.
In coastal installations aluminum enclosures need a coating suited to salt-laden air; select the finish with your corrosion specification in mind.
Checking compatibility for TDZ2/TPRG/4-20MA/12-42DC [BH2NGP]
Check the entry thread: N means 1/2-inch NPT, T would be 3/4-inch NPT and M would be M20 x 1.5. If you require stainless steel, the SB2NG and SB2MG enclosures provide it. For ATEX documentation ask for the E suffix variant instead.
Make sure the loop power supply is at least 12 V at the terminals; HART communication wants 250 to 1100 ohms.
Fitting and commissioning TDZ2/TPRG/4-20MA/12-42DC [BH2NGP]
Fix the base plate to the pipe with the U-bolts, install the glands, connect the sensor and loop, and refit the glass cover. Switch on, wait for the display, then use HART or the PC software to choose the input, range and units shown on the display.
Set the display to show input, output or alternate between them; the HART address appears as two digits.
During start-up check the loop with a handheld communicator in the three common modes: poll the HART variables, run a loop test at 4, 12 and 20 mA, and read back the sensor diagnostics. Write the tag and the descriptor into the unit so the HART host shows the instrument name rather than a default.
Upkeep of TDZ2/TPRG/4-20MA/12-42DC [BH2NGP]
Clean the glass window and check seals during inspections. Verify the measurement against a calibrated source, and re-trim if needed. The stability tables in the datasheet allow multi-year intervals.
Keep the record of the configured range and display units with the maintenance file.
Supply of TDZ2/TPRG/4-20MA/12-42DC [BH2NGP]
Quote TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] in full in any enquiry and add the sensor type.
Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer; all names and part numbers are used only to identify the product being requested.
Documents and quotation
The datasheet for Moore Industries TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] can be attached to our quotation. Send an RFQ with the part number, quantity and destination.
Other Models in the THZ2 TDZ2 Range
Seven Star LLC supplies models from the THZ2 TDZ2 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Moore Industries TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] Transmitter | Temperature Transmitters | You are viewing this model |
| Moore Industries THZ2/TPRG/4-20MA/12-42DC [LH2NSP] Transmitter | Temperature Transmitters | View details |
| Moore Industries THZ2/HLPRG/4-20MA/12-42DC [DIN] Isolator | Isolator & Barrier | View details |
Datasheets & Documents
- Datasheet Moore Industries TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.
Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.
Moore Industries company profile
| Founded | 1968, North Hills, California, USA, by Leonard W. Moore |
|---|---|
| Headquarters | North Hills, California, since 1974 |
| Ownership | Privately owned (Moore Industries-International, Inc.) |
| First product | SCT signal converter |
| Product families | Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA) |
Milestones
- 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
- 1974: The company moves into its North Hills headquarters.
- 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.
Moore Industries product families on this page
The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:
- Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
- Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
- Signal isolators, repeaters and converters: the SIX
- PID controllers and backup stations: the 535 in 1/4 DIN format
Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.
Where Moore Industries instruments are used
These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.
Moore Industries products we list
Ordering Moore Industries instruments: what we need
Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.
Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.
Browse Moore Industries products by category: Temperature Instrumentation, Controllers & Data Acquisition, Isolator & Barrier.
FAQ
Questions about the Moore Industries TDZ2/TPRG/4-20MA/12-42DC [BH2NGP]
Answers from our engineering team on installation, compatibility and integration.
01What does the P in BH2NGP mean?
It indicates the enclosure comes with a base plate and U-bolts for mounting on a 2-inch pipe.
02How heavy is the TDZ2 in a BH enclosure?
The datasheet lists 1.4 kg (50.2 oz) for the HP module in the BH enclosure.
03How does TDZ2 differ from THZ2?
TDZ2 has an integral display with 10 mm and 6 mm digits and is delivered in field enclosures, while THZ2 is a module for heads or DIN rail.
04What RFI immunity is quoted?
20 V/m when tested according to IEC 61326 with 0.5% of span or less error.
05Can the display be scaled?
Yes. The display range is -99999 to 99999 with automatic decimal point of up to two places for the process value.

















![Moore Industries TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] Transmitter Moore Industries TDZ2/TPRG/4-20MA/12-42DC [BH2NGP] Transmitter](https://omansevenstar.com/wp-content/uploads/2026/11/moore-industries-tdz2-tprg-4-20ma-12-42dc-bh2ngp-smart-hart-display-transmitter-bh-enclosure.webp)
Reviews