Endress+Hauser PMD55 Deltabar M Differential Pressure Transmitter

Description

Endress+Hauser PMD55 Deltabar M compact differential pressure transmitter

The Endress+Hauser PMD55 is a Deltabar M differential pressure transmitter for flow measurement with primary elements in gases, vapours and liquids, for level, volume and mass in liquids, and for differential pressure monitoring of filters and pumps. The compact transmitter design and DIP-switch commissioning make it quick to put into service.

A reference accuracy of 0.10 percent is stated for the Endress+Hauser PMD55, and up to 0.075 percent for the PLATINUM version. Turn down is up to 100 to 1, and the device is used for process pressure monitoring up to SIL 2, certified to IEC 61508 Edition 2.0 and IEC 61511 by TUEV NORD. It shares a uniform platform with Cerabar M and Deltapilot M.

Key features of the PMD55

  • Reference accuracy 0.10 percent, up to 0.075 percent in the PLATINUM version
  • Turn down up to 100 to 1
  • Compact transmitter design with fast commissioning via DIP switches
  • Uniform platform with Cerabar M and Deltapilot M for simple spares and training
  • SIL 2 capable (IEC 61508 Edition 2.0, IEC 61511, TUEV NORD)
  • HART 6.0, PROFIBUS PA and FOUNDATION Fieldbus options for the PMD55

PMD55 technical specifications

Parameter Value
Product family Deltabar M, type PMD55
Measured variables Differential pressure, flow with primary elements, level, volume and mass in liquids
Reference accuracy 0.10 percent; PLATINUM up to 0.075 percent
Turn down Up to 100 to 1
Output signal 4 to 20 mA with HART 6.0, PROFIBUS PA, FOUNDATION Fieldbus
Ambient temperature Minus 40 to plus 85 degrees C; with display minus 20 to plus 70 degrees C (extended range with limited display performance)
Functional safety SIL 2 (IEC 61508 Edition 2.0, IEC 61511, TUEV NORD)
Commissioning Menu operation or DIP switches

Numbers are quoted from the manufacturer Technical Information for the PMD55. Ranges and process connections are set in the ordering code, and hazardous area approvals vary by version.

Typical applications in Oman and the GCC

In oil and gas, the PMD55 is used for orifice plate flow, filter and strainer differential pressure and tank level in separators and storage. HART diagnostics help technicians check the device quickly in remote facilities, and the SIL 2 capability supports protective loops.

Water, wastewater, cooling and power plants use the device for filter monitoring, pump differential pressure and flow with primary elements. In manufacturing plants it is used for clean room pressure, tank level and steam flow, where the compact size and easy setup help.

Selection and compatibility notes for the PMD55

Select the PMD55 for general differential pressure, level and flow duties where up to 0.10 percent accuracy is enough. For higher accuracy, SIL 3 or heavy-duty diaphragm seals, move to the Deltabar S PMD75, and for the new generation with Bluetooth look at the PMD78B. Specify the cell range, static pressure rating, seal material and output type in the RFQ for the device.

Installation and commissioning of the PMD55

Mount the PMD55 so that the process connection sits as close to the measuring point as practical and, for liquids, so that no gas pocket can collect in front of the diaphragm. For gases, mount above the tapping point so condensate drains back into the line. Any change of mounting orientation shifts the zero point slightly, so correct the position offset once the device is in its final position and the line is at atmospheric or reference pressure. Use a shut-off valve or a valve manifold so that the device can be isolated and checked without stopping the process, and use a shielded two-core cable with the shield grounded at one end only. Commissioning of the device is a matter of checking the supply voltage at the terminals, setting the lower and upper range values, choosing the damping, and confirming the output at a known pressure.

Maintenance

The PMD55 has no wearing parts, so routine maintenance is limited to periodic inspection. Check the process connection and seal for leakage, look for blocked impulse lines or crystallised product, and verify the zero point at atmospheric pressure when the process allows it. Where a safety function is involved, follow the proof-test interval stated in the safety manual of the device. Replace seals whenever the connection is opened, and keep the diaphragm free of buildup by flushing rather than by scraping, because a scratched diaphragm changes the measurement. Record the as-found and as-left values at every check so that drift of the device can be trended over the years.

Related products and ordering notes

Related devices include the Deltabar S PMD75, the Deltapilot M FMB50 and the Cerabar M PMC51. Three- and five-valve manifolds can be added to the RFQ for the PMD55.

In short: the device is a compact differential pressure transmitter with 0.10 percent accuracy, 100 to 1 turn down and SIL 2 capability. Send an RFQ for availability. When you prepare the enquiry, state the pressure type (gauge or absolute), the lower and upper range values, the wetted material you need, the thread or flange size, the cable entry and any hazardous area marking. A complete enquiry lets us answer quickly and avoids a second round of questions, and it also helps to say whether the device will be used in a safety loop, because that changes the documentation you should request.

Before shipment, a pressure transmitter should be checked for the right range, the right wetted materials, an undamaged diaphragm protection cap and a legible nameplate. We recommend that receiving staff compare the nameplate data with the purchase order, keep the protective cap on until the moment of installation, and store the unit in a dry place. If the application involves oxygen, hydrogen or ultrapure gas, state this in the enquiry so that the correct cleaning and documentation are requested.

Documents and quotation

The official Endress+Hauser Deltabar M PMD55 Technical Information (TI00434P) is attached to this page as a PDF. The front page states a reference accuracy of 0.10 % (up to 0.075 % as PLATINUM version) and fast commissioning via DIP switches, the Performance characteristics chapter starts on page 19, and the Ordering information chapter begins on page 45. Include the PMD55 order code, the required range and the process conditions in your inquiry and we will reply with availability and a written quotation.

Other Models in the Eh Deltabar Range

Seven Star LLC supplies models from the Eh Deltabar range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser PMD75 Deltabar S Differential Pressure TransmitterPressure TransmittersView details
Endress+Hauser PMD55 Deltabar M Differential Pressure TransmitterPressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser Deltabar M PMD55 Technical Information TI00434P (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser PMD55 Deltabar M Differential

Answers from our engineering team on installation, compatibility and integration.

01What is the accuracy of the PMD55?
The datasheet gives a reference accuracy of 0.10 percent and up to 0.075 percent in the PLATINUM version.
02Can the PMD55 be commissioned without a handheld?
Yes. The datasheet highlights fast commissioning via DIP switches and a user interface designed for real-world applications.
03Which communication options does the PMD55 have?
The output is 4 to 20 mA with HART 6.0, PROFIBUS PA or FOUNDATION Fieldbus, depending on the ordering code.
04What safety level does the PMD55 support?
It is used for process pressure monitoring up to SIL 2, certified to IEC 61508 Edition 2.0 and IEC 61511 by TUEV NORD.
05How do I order the PMD55?
Send an RFQ to Seven Star LLC with the part number PMD55, quantity, range and connection details, and we reply with availability and a quotation.