Endress+Hauser PMP71 Cerabar S Pressure Transmitter, Metal Sensor

Description

Endress+Hauser PMP71 Cerabar S pressure transmitter with metal sensor for high pressure

The Endress+Hauser PMP71 is the metal-sensor member of the Cerabar S family, meant for absolute and gauge pressure in gases, steam and liquids and for level, volume or mass measurement in liquids. Cerabar S devices as a group reach pressures up to 700 bar (10,500 psi), which makes the Endress+Hauser PMP71 the natural choice for high-pressure process lines.

Like the PMC71, the device offers a reference accuracy of up to plus or minus 0.025 percent, turn down up to 100 to 1 and SIL 3 certification for process pressure monitoring under IEC 61508 by TUEV SUED. Process temperatures up to 150 degrees C are possible without a diaphragm seal, and up to 400 degrees C with typical diaphragm seals when the PMP75 variant is used.

Key features of the PMP71

  • Metal sensor for high-pressure duties within a Cerabar S family that reaches 700 bar
  • Reference accuracy up to plus or minus 0.025 percent on the PMP71
  • Turn down up to 100 to 1, higher on request
  • SIL 3 process pressure monitoring certified to IEC 61508 by TUEV SUED
  • Continuous function monitoring from measuring cell to electronics
  • HistoRom/M-DAT for fast electronics replacement and configuration transfer

PMP71 technical specifications

Parameter Value
Product family Cerabar S, type PMP71
Sensor Metal
Measured variables Absolute and gauge pressure; level, volume and mass in liquids
Reference accuracy Up to plus or minus 0.025 percent
Turn down Up to 100 to 1, higher on request
Output signal 4 to 20 mA HART in the family; PROFIBUS PA and FOUNDATION Fieldbus also described
Supply voltage, HART 10.5 to 45 V DC
Process temperature Up to 150 degrees C without diaphragm seal
Functional safety SIL 3 (IEC 61508, TUEV SUED)
Family pressure capability Up to 700 bar (10,500 psi)

The numbers come from the Cerabar S Technical Information that covers the PMP71. Individual ranges, materials and process connections are fixed by the ordering code.

Typical applications in Oman and the GCC

The PMP71 suits high-pressure oil and gas duties such as gas lift lines, pipeline pressure, high-pressure separators and test rigs. Its function monitoring and SIL 3 certification support trips and shutdown functions, while its stable signal helps with fiscal-grade pressure compensation in gas measurement.

In power and water systems, the device can monitor boiler feed, steam and high-head pump discharge. Manufacturing plants use it on hydraulic systems, autoclaves and reactor lines where pressure peaks and stable accuracy matter.

Selection and compatibility notes for the PMP71

Select the PMP71 for high pressure or where a metal sensor is preferred, and the PMC71 where a ceramic sensor fits. Use the PMP75 when diaphragm seals are required for hot or aggressive media. Compare the device with the Cerabar M PMP51 if the accuracy and SIL 3 level of the S family are not required; PMP51 reaches 400 bar and is simpler. Confirm the sensor range, process connection and approvals in the ordering code.

Installation and commissioning of the PMP71

Mount the PMP71 so that the process connection sits as close to the measuring point as practical and, for liquids, so that no gas pocket can collect in front of the diaphragm. For gases, mount above the tapping point so condensate drains back into the line. Any change of mounting orientation shifts the zero point slightly, so correct the position offset once the device is in its final position and the line is at atmospheric or reference pressure. Use a shut-off valve or a valve manifold so that the device can be isolated and checked without stopping the process, and use a shielded two-core cable with the shield grounded at one end only. Commissioning of the device is a matter of checking the supply voltage at the terminals, setting the lower and upper range values, choosing the damping, and confirming the output at a known pressure.

Maintenance

The PMP71 has no wearing parts, so routine maintenance is limited to periodic inspection. Check the process connection and seal for leakage, look for blocked impulse lines or crystallised product, and verify the zero point at atmospheric pressure when the process allows it. Where a safety function is involved, follow the proof-test interval stated in the safety manual of the device. Replace seals whenever the connection is opened, and keep the diaphragm free of buildup by flushing rather than by scraping, because a scratched diaphragm changes the measurement. Record the as-found and as-left values at every check so that drift of the device can be trended over the years.

Related products and ordering notes

Related products include the Cerabar S PMC71, the Cerabar M PMP51 and the Deltabar S PMD75. Valve manifolds and brackets can be requested together with the PMP71.

In short: the PMP71 is a metal-sensor Cerabar S for demanding duties with up to 0.025 percent accuracy and SIL 3 certification. Ask for a quotation by RFQ. When you prepare the enquiry, state the pressure type (gauge or absolute), the lower and upper range values, the wetted material you need, the thread or flange size, the cable entry and any hazardous area marking. A complete enquiry lets us answer quickly and avoids a second round of questions, and it also helps to say whether the device will be used in a safety loop, because that changes the documentation you should request.

Before shipment, a pressure transmitter should be checked for the right range, the right wetted materials, an undamaged diaphragm protection cap and a legible nameplate. We recommend that receiving staff compare the nameplate data with the purchase order, keep the protective cap on until the moment of installation, and store the unit in a dry place. If the application involves oxygen, hydrogen or ultrapure gas, state this in the enquiry so that the correct cleaning and documentation are requested.

Documents and quotation

The official Endress+Hauser Cerabar S PMC71, PMP71, PMP75 Technical Information (TI00383P) is attached to this page as a PDF. Metallic-membrane performance data for the PMP71 is in its own chapter from page 32, the document covers pressures up to 700 bar (10,500 psi), and the Planning instructions for diaphragm seal systems start on page 112 for high-temperature or aggressive media. Send us the full order code of your PMP71 with the measuring range and process connection and we will confirm availability and lead time in a written quotation.

Other Models in the Eh Cerabar Range

Seven Star LLC supplies models from the Eh Cerabar range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser PMC51 Cerabar M Pressure Transmitter, CeramicPressure TransmittersView details
Endress+Hauser PMP51 Cerabar M Pressure Transmitter, Metal MembranePressure TransmittersView details
Endress+Hauser PMC71 Cerabar S Pressure Transmitter, CeramicPressure TransmittersView details
Endress+Hauser PMP71 Cerabar S Pressure Transmitter, Metal SensorPressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser Cerabar S PMC71, PMP71 Technical Information TI00383P (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser PMP71 Cerabar S Pressure

Answers from our engineering team on installation, compatibility and integration.

01What pressure can the PMP71 handle?
The Cerabar S Technical Information lists high pressures up to 700 bar (10,500 psi) for the family. The range of a specific PMP71 is set by the ordering code.
02How accurate is the PMP71?
The reference accuracy is up to plus or minus 0.025 percent according to the manufacturer datasheet for the Cerabar S family.
03Is the PMP71 certified for safety loops?
The family is certified up to SIL 3 for process pressure monitoring under IEC 61508 by TUEV SUED.
04What temperature can the PMP71 measure without a diaphragm seal?
The datasheet gives process temperatures up to 150 degrees C without a diaphragm seal and up to 400 degrees C with typical diaphragm seals.
05Where do I send an RFQ for the PMP71?
Send it to Seven Star LLC with the part number PMP71, quantity, pressure range, process connection and output signal, and we reply with availability and an offer.