- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ABB
ABB MS132-0.63 Manual Motor Starter 0.40-0.63 A
Description
ABB MS132-0.63 manual motor starter, 0.40 to 0.63 A setting range
The ABB MS132-0.63 is a three-pole manual motor starter, also called a motor protection circuit breaker, for the main circuit. Its thermal overload release is adjustable from 0.40 to 0.63 A, its magnetic release trips instantaneously between 4.91 to 7.37 A, and the catalogue assigns it the order code 1SAM350000R1004. ABB lists the family with trip class 10, a 45 mm wide housing and an ON/OFF/TRIP handle that can be padlocked.
With a setting range of 0.40 to 0.63 A the type is a good match for 0.12 to 0.18 kW class motors on small conveyors, mixers, lubrication pumps and compact blowers, where the dial can be set close to the nameplate value.
Reading the MS132-0.63 type code
MS stands for manual motor starter with thermal and electromagnetic protection, 132 is the performance frame, and the number after the dash is the upper limit of the adjustable current range in amperes. The device therefore carries the overload and short-circuit functions in one body, without a separate fuse or overload relay.
MS132-0.63 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | ABB / MS132-0.63 |
| Order code | 1SAM350000R1004 |
| Setting range, thermal overload protection | 0.40 to 0.63 A |
| Rated instantaneous short-circuit current setting Ii | 4.91 to 7.37 A |
| Rated power at 400 V (catalogue) | 0.18 kW |
| Trip class | 10 |
| Number of poles | 3 |
| Rated operational voltage Ue | 690 V AC, 250 V DC |
| Rated frequency | 50 / 60 Hz |
| Ics / Icu at 230 V AC and 400 V AC | 100 kA / 100 kA, no back-up fuse required |
| Ics / Icu at 690 V AC | 100 kA / 100 kA, no back-up fuse required |
| Rated impulse withstand voltage Uimp | 6 kV |
| Rated insulation voltage Ui | 690 V |
| Pollution degree | 3 |
| Resistance per phase | 4.36 Ω |
| Power loss per phase | 0.7 W at the lower and 1.7 W at the upper end of the range |
| Main terminals | 1 or 2 x 1 to 4 mm² solid; 1 or 2 x 0.75 to 2.5 mm² flexible; M3.5 Pozidriv 2 screw, 0.8 to 1.2 Nm, strip 9 mm |
| Degree of protection | IP20 (enclosure and terminals) |
| Ambient temperature, operation | -25 to +60 °C compensated without derating; open up to +70 °C |
| Storage temperature | -50 to +80 °C |
| Mounting | 35 mm DIN rail (EN 60715); screw-fixing kit available |
| Mechanical / electrical durability | 105 / 5 x 104 operations |
| Weight | 215 g |
| Altitude | up to 2000 m |
How the MS132-0.63 protects the motor
A bimetal-based thermal release follows the motor current and trips on sustained overload. The scale is calibrated in amperes and is set to the motor nameplate current, not to a trip current: according to the data sheet there is no tripping at 1.05 times the setting and tripping at 1.2 times the setting. Temperature compensation keeps this behaviour stable across -25 to +60 °C, which matters in hot switchrooms.
A separate electromagnetic release reacts to short circuits within milliseconds. For the ABB MS132-0.63 the instantaneous setting lies between 4.91 to 7.37 A. A trip-free mechanism means the contacts open even if the handle is held in the ON position, and the handle shows ON, OFF or TRIP so that an operator can see what happened. The device is sensitive to phase loss and has a built-in disconnect function for safe isolation of the load.
Selecting the MS132-0.63 for your motor
The motor nameplate current at the actual supply voltage must lie inside 0.40 to 0.63 A, ideally in the upper part of the dial so that the setting is not on the minimum stop. If the nameplate shows a value below 0.40 A use the smaller neighbour MS132-0.4; if it is above 0.63 A move to MS132-1.0.
- Read the nameplate current for the actual voltage and frequency.
- Check that it falls inside 0.40 to 0.63 A.
- Compare the magnetic setting (4.91 to 7.37 A) with the motor starting current, particularly for high-efficiency motors with strong inrush.
- Confirm the 100 kA short-circuit rating covers the prospective fault level of the board.
- Choose accessories from the MS116 / MS132 range and decide on a contactor for remote switching.
Where the MS132-0.63 fits in the system
The nearest neighbours in the frame are MS132-0.4, MS132-1.0 and the rest of the MS132 line: MS132-0.16, MS132-0.25, MS132-0.4, MS132-0.63, MS132-1.0, MS132-1.6, MS132-2.5, MS132-4.0, MS132-6.3, MS132-10, MS132-12, MS132-16, MS132-20, MS132-25 and MS132-32. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, busbar systems and in-feed blocks are accessories of the manual motor starter range, and the same accessories are shared across MS116 and MS132. Combined with an AF-series contactor the starter becomes a compact direct-on-line starter in which the manual motor starter provides the protection and disconnect function and the contactor handles switching.
UL and CSA data for the MS132-0.63
For North American motor ratings the data sheet lists, at 220 to 240 V single phase, a full-load current of 0.63 A and a locked-rotor current of 3.78 A for this type, with no horsepower rating assigned. No horsepower rating is assigned at three-phase 500 to 600 V. The maximum operational voltage under UL/CSA is 600 V. The device is listed to UL 508 as a manual motor controller; check the listing table of the data sheet for the group-installation and tap-conductor values before using it in a UL panel.
Installation, commissioning and maintenance
- Snap the starter onto a 35 mm DIN rail or use the screw-fixing kit on a mounting plate.
- Strip the conductors by 9 mm and tighten the M3.5 terminal screws to 0.8 to 1.2 Nm using a Pozidriv 2 screwdriver.
- Keep 0 mm horizontal and 150 mm vertical spacing to other units of the same type; allow more than 1.5 mm to earthed walls above 400 V.
- Set the dial to the nameplate current and operate the handle and the trip test during commissioning.
- Switch the device mechanically from time to time and re-tighten terminals after the first weeks of service, because thermal cycling can loosen small terminal screws.
The device tolerates vibration of 5 g between 3 and 150 Hz and shock of 25 g for 11 ms, and operates up to 2000 m altitude. In Oman and the GCC the main stresses are heat, dust and humidity, so install it in a ventilated and sealed enclosure and keep clear of direct sun on panel doors.
Typical applications in Oman and the GCC
Small motors are everywhere in process and utility plants. In oil and gas facilities this size of starter protects dosing pumps, small fans and instrument-cabinet auxiliaries in field junction boxes. Desalination and water-treatment plants use fractional-kilowatt motors for chemical dosing, mixers and sampling. In power stations and substations they appear in ventilation and heating circuits, and in petrochemical sites in analyser houses and skid-mounted packages. Because the starter replaces a fuse and an overload relay with one 45 mm body it saves space in crowded control panels.
Fine-range MS132 types compared
| Type | Setting range | Order code | Ii setting |
|---|---|---|---|
| MS132-0.16 | 0.10 to 0.16 A | 1SAM350000R1001 | 1.25 to 1.87 A |
| MS132-0.25 | 0.16 to 0.25 A | 1SAM350000R1002 | 1.95 to 2.92 A |
| MS132-0.4 | 0.25 to 0.40 A | 1SAM350000R1003 | 3.12 to 4.68 A |
| MS132-0.63 | 0.40 to 0.63 A | 1SAM350000R1004 | 4.91 to 7.37 A |
| MS132-1.0 | 0.63 to 1.00 A | 1SAM350000R1005 | 9.20 to 13.8 A |
Information to send with an RFQ
- Motor nameplate power, current, voltage and frequency.
- Prospective short-circuit current at the board.
- Accessories required: auxiliary contacts, shunt trip, undervoltage release or busbar.
- Whether a contactor is to be combined with the starter.
- Quantity and delivery location in Oman or the GCC.
Documents and quotation
The MS132 data sheet is attached on this page and covers ordering details, characteristics, dimensions and UL/CSA tables. Send the part number MS132-0.63 together with the motor data and we will confirm availability and delivery.
Seven Star LLC supplies industrial electrical products in Oman and the GCC and can quote MS132-0.63 together with matching accessories.
Other Models in the Abb Ms132 Manual Motor Starter Range
Seven Star LLC supplies models from the Abb Ms132 Manual Motor Starter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB MS132-1.6 Manual Motor Starter 1.0-1.6 A | Contactors & Overload Relays | View details |
| ABB MS132-2.5 Manual Motor Starter 1.6-2.5 A | Contactors & Overload Relays | View details |
| ABB MS132-4.0 Manual Motor Starter 2.5-4.0 A | Contactors & Overload Relays | View details |
| ABB MS132-6.3 Manual Motor Starter 4.0-6.3 A | Contactors & Overload Relays | View details |
| ABB MS132-12 Manual Motor Starter 8.0-12 A | Contactors & Overload Relays | View details |
| ABB MS132-20 Manual Motor Starter 16-20 A | Contactors & Overload Relays | View details |
| ABB MS132-0.16 Manual Motor Starter 0.10-0.16 A | Contactors & Overload Relays | View details |
| ABB MS132-0.25 Manual Motor Starter 0.16-0.25 A | Contactors & Overload Relays | View details |
| ABB MS132-0.4 Manual Motor Starter 0.25-0.40 A | Contactors & Overload Relays | View details |
| ABB MS132-0.63 Manual Motor Starter 0.40-0.63 A | Contactors & Overload Relays | You are viewing this model |
| ABB MS132-1.0 Manual Motor Starter 0.63-1.00 A | Contactors & Overload Relays | View details |
Datasheets & Documents
- Datasheet ABB MS132-0.63 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB MS132-0.63 Manual Motor Starter 0.40-0.63 A
Answers from our engineering team on installation, compatibility and integration.
01What current range does the MS132-0.63 cover?
The thermal release of the MS132-0.63 is adjustable from 0.40 to 0.63 A. Set the dial to the motor nameplate current inside that range, since the data sheet defines the setting as the motor rated current.
02What is the short-circuit breaking capacity of the MS132-0.63?
The data sheet gives Ics and Icu of 100 kA at 230 V and 400 V AC for the MS132-0.63, with no back-up fuse required. Always compare this with the prospective fault level of the installation.
03At what current does the MS132-0.63 trip magnetically?
The rated instantaneous short-circuit current setting Ii of the MS132-0.63 lies between 4.91 to 7.37 A. The thermal release does not trip at 1.05 times the setting and trips at 1.2 times the setting.
04How is the MS132-0.63 mounted and wired?
It snaps onto a 35 mm DIN rail, or is fixed with a screw kit. Main terminals take 1 or 2 conductors of 1 to 4 mm² solid or 0.75 to 2.5 mm² flexible, tightened to 0.8 to 1.2 Nm.
05Does the MS132-0.63 also provide isolation and phase-loss protection?
Yes, the data sheet lists a disconnect function, phase loss sensitivity, trip indication and a lockable handle. It can be fitted with auxiliary contacts, a shunt trip or an undervoltage release.


















Reviews
There are no reviews yet.