Brand: Schneider Electric
Schneider Electric RPM22BD RPM Relay 24 V DC
Description
RPM22BD RPM power plug-in relay and its part number
RPM22BD is an RPM power plug-in relay from the Schneider Electric Harmony Electromechanical Relays range. Its datasheet lists 2 C/O contacts, a DC coil rated 24 V DC, and a status LED fitted. Mounting is plug-in, with flat faston-type pins.
Reading the code from the datasheets of this family: RPM22 = RPM series power relay with two changeover contacts; the suffix BD stands for the coil, here 24 V DC. This reading follows how the sibling datasheets line up and is not an ordering table, so verify the full code against the manufacturer catalogue when it matters.
Seven Star LLC supplies RPM22BD in Oman and the GCC as an independent supplier in Muscat. The datasheet we hold is dated 8 Nov 2026.
Sockets and related parts for RPM22BD
The matching sockets are RPZF2 for the two-pole RPM relay and RPZF4 for the four-pole one; the datasheet of the socket confirms RPM with 2 C/O contact for RPZF2.
The same series also includes the following parts, which share the basic body of RPM22BD but differ as shown:
- Against RPM22P7: coil 24 V DC against 230 V AC 50/60 Hz on RPM22P7; drop-out ≥ 0.1 Uc DC against ≥ 0.15 Uc AC on RPM22P7.
Because the differences are in the coil or contact details, the complete part number must be confirmed before ordering.
Coil circuit and supply window of RPM22BD
The coil of RPM22BD is rated 24 V DC with voltage limits of 19.2–26.4 V DC. The datasheet gives an average coil resistance of 640 Ohm at 20 °C ± 10 % and average consumption of 0.85 W. The relay releases when the control voltage falls to ≥ 0.1 Uc DC, which is the figure to compare against any sagging control supply or leakage from a PLC output.
Operating time is 20 ms at nominal voltage and release time 20 ms at nominal voltage. An LED shows coil energisation, and the lockable test button allows manual operation checks.
A 24 V DC coil is the usual match for PLC digital outputs and regulated control rails, so check that the output card can source the coil current and that the rail is not shared with noisy inductive loads.
Installation, commissioning and maintenance
Fit the relay to its socket until it seats and, where a retaining feature is provided, secure it before energising. Do not hot-swap relays that are carrying load. For RPM22BD the datasheet states -40–55 °C for operation and IP rating IP40 conforming to IEC 60529, so plan cabinet ventilation accordingly.
During commissioning, energise the coil at its nominal voltage, check contact transfer with a meter, and verify that the supply stays inside the voltage limits. In service, inspect for discoloured pins, replace relays that show contact wear, and keep a spare on the shelf for critical interlocks.
RPM22BD technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / RPM22BD |
| Range / series | Harmony Electromechanical Relays, RPM series, power relay |
| Contacts | 2 C/O |
| Coil (control) voltage | 24 V DC |
| Coil voltage limits | 19.2–26.4 V DC |
| Average coil resistance | 640 Ohm at 20 °C ± 10 % |
| Average coil consumption | 0.85 W |
| Drop-out threshold | ≥ 0.1 Uc DC |
| Status LED | Yes |
| Control / test | Lockable test button |
| Conventional thermal current | 15 A at -40–55 °C |
| Rated operational current | 15 A at 277 V (AC) conforming to UL; 15 A at 28 V (DC) conforming to UL; 15 A at 250 V (AC) NO conforming to IEC; 15 A at 28 V (DC) NO conforming to IEC; 7.5 A at 250 V (AC) NC conforming to IEC; 7.5 A at 28 V (DC) NC conforming to IEC |
| Maximum switching capacity | 3750 VA; 420 W |
| Minimum switching capacity | 170 mW at 10 mA, 17 V |
| Maximum switching voltage | 250 V conforming to IEC |
| Operate / release time | 20 ms at nominal voltage |
| Mechanical durability | 10000000 cycles |
| Electrical durability | 100000 cycles for resistive load |
| Contact material | AgNi |
| Pin shape | Flat (faston type) |
| Insulation voltage | 250 V conforming to IEC; 300 V conforming to CSA; 300 V conforming to UL |
| Dielectric strength | 1500 V AC between contacts with micro disconnection; 2000 V AC between coil and contact with reinforced; 2000 V AC between poles with basic |
| Impulse withstand | 4 kV during 1.2/50 µs |
| Operating temperature | -40–55 °C |
| Storage temperature | -40–85 °C |
| Protection | IP40 conforming to IEC 60529 |
| Standards | CSA C22.2 No 14; IEC 61810-1; UL 508 |
| Certifications | EAC; UL; CSA |
| Net weight | 0.036 kg |
Typical use of RPM22BD in Oman and the GCC
Relays of this class are used as interposing and interface devices between controllers and field loads in power generation, water treatment and desalination, oil and gas skids, and building automation across Oman. Heat inside sun-exposed cabinets and salt-laden coastal air are the main points to design for; the datasheet lists pollution degree 3 and IP rating IP40 conforming to IEC 60529.
RPM22BD suits panels that need 2 C/O switching with a status LED fitted and a lockable test button, and where the supply is 24 V DC.
Family comparison and RFQ details
| Part number | Coil | LED | Resistance | Drop-out |
|---|---|---|---|---|
| RPM22BD (this page) | 24 V DC | Yes | 640 Ohm | ≥ 0.1 Uc DC |
| RPM22P7 | 230 V AC 50/60 Hz | Yes | 16270 Ohm | ≥ 0.15 Uc AC |
For a quotation on RPM22BD please send the exact part number, quantity, coil voltage, delivery location in Oman or the GCC and any project reference. If your drawing lists a different coil voltage, say so and we will check the matching variant.
Selection and ordering checklist for RPM22BD
Before ordering RPM22BD confirm:
- Control voltage: 24 V DC (19.2–26.4 V DC); AC and DC versions are not interchangeable.
- Contact load: check the load against 3750 VA; 420 W and the current table above.
- Indicator needs: this version is with a status LED.
- Socket type and terminal style matching the relay pins.
- Quantity and whether a spare relay should be held for the plant.
Contact ratings and switching limits
Contact data for this unit: maximum switching capacity 3750 VA; 420 W, minimum switching capacity 170 mW at 10 mA, 17 V; contact material AgNi.
Rated operational current entries:
- 15 A at 277 V (AC) conforming to UL
- 15 A at 28 V (DC) conforming to UL
- 15 A at 250 V (AC) NO conforming to IEC
- 15 A at 28 V (DC) NO conforming to IEC
- 7.5 A at 250 V (AC) NC conforming to IEC
- 7.5 A at 28 V (DC) NC conforming to IEC
Durability: 100000 cycles for resistive load; operating rate ≤ 1200 cycles/hour under load and ≤ 18000 cycles/hour no-load. Derate for inductive or DC loads and follow the curves in the datasheet.
Documents and quotation
The datasheet for this unit is attached to this page (document dated 8 Nov 2026). Please treat it as the reference for every figure above, and tell us if your project specification asks for anything the datasheet does not state.
Send the part number, quantity, required delivery point and any project reference through the quotation form or by email. Seven Star LLC is an independent industrial supplier based in Muscat, serving customers across Oman and the GCC, and we reply with availability and lead time for this exact part number.
Datasheets & Documents
- Datasheet Schneider Electric RPM22BD Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric RPM22BD RPM Relay 24 V DC
Answers from our engineering team on installation, compatibility and integration.
01What coil voltage does RPM22BD use?
24 V DC, with limits of 19.2–26.4 V DC.
02What contacts does RPM22BD have?
2 C/O contacts with AgNi contact material and a maximum switching capacity of 3750 VA; 420 W.
03Does RPM22BD have an LED?
Yes, it has a status LED. See the datasheet linked on this page for the full figures.
04What temperature range applies to RPM22BD?
Operation is stated as -40–55 °C and storage as -40–85 °C.
05How long does RPM22BD last?
Mechanical durability is 10000000 cycles; electrical durability is 100000 cycles for resistive load.


















Reviews