- Automation & ControlView all 1,652 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- Isolator & Barrier
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser Promass F 200 Loop-Powered Coriolis Flowmeter
Description
Promass F 200 loop-powered Coriolis flowmeter for demanding liquids and gases
The Endress+Hauser Promass F 200 is a two-wire, loop-powered Coriolis mass flowmeter built around the Promass F bent dual-tube sensor. It is the high-performance option in the Promass range: mass flow accuracy of ±0.10 % of reading for liquids and ±0.25 % for gases, nominal sizes from DN 8 to DN 80 (3/8 to 3 in), and a medium temperature up to +205 °C with the extended version. Because the transmitter draws its power from the 4-20 mA loop, it can replace older loop-powered instruments without new power cabling. Seven Star LLC supplies the Promass F 200 in Oman and the GCC as an independent supplier in Muscat.
The meter delivers mass flow, density and temperature simultaneously, and the transmitter calculates volume flow, corrected volume flow and reference density.
What the Promass F 200 name means
- Promass F: the dual-tube sensor with the widest choice of tube materials (904L, 316/316L or Alloy C22) and the highest performance class.
- 200: the Proline 200 transmitter, loop-powered, with a separate connection compartment, touch-control display with background lighting, and no need to open the housing for operation.
- Output options are coded: A (4-20 mA HART), B (HART plus pulse/frequency/switch), C (HART plus second 4-20 mA), E (FOUNDATION Fieldbus) and G (PROFIBUS PA).
The sensor, housing, tube material, connection and approvals are chosen through the order code. Send a nameplate photo if you need a like-for-like replacement.
Promass F 200 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser / Promass F 200 (Proline Coriolis flowmeter) |
| Sensor | Bent dual-tube Coriolis, DN 8 to DN 80 (3/8 to 3 in) |
| Liquid full-scale values | DN 8: 2,000; DN 15: 6,500; DN 25: 18,000; DN 40: 45,000; DN 50: 70,000; DN 80: 180,000 kg/h |
| Mass and volume flow accuracy (liquids) | ±0.10 % of reading |
| Mass flow accuracy (gases) | ±0.25 % of reading |
| Density accuracy (liquids) | ±0.0005 g/cm³ reference and standard; ±0.001 g/cm³ wide-range; ±0.0005 g/cm³ extended density option |
| Repeatability | ±0.05 % (liquids); ±0.20 % (gases); density ±0.00025 g/cm³ |
| Zero point stability | DN 8: 0.180; DN 15: 0.585; DN 25: 1.62; DN 40: 4.05; DN 50: 6.30; DN 80: 16.2 kg/h |
| Medium temperature | Standard −50 to +150 °C; extended −50 to +205 °C |
| Medium density | 0 to 2,000 kg/m³ |
| Pressure ratings | Up to PN 100 / Class 600 / 63K depending on connection |
| Wetted materials | Tubes 1.4539 (904L), 1.4404 (316/316L) or Alloy C22; connections 1.4404, 1.4301 or Alloy C22 |
| Power | Loop-powered: minimum terminal voltage 17.9 V at 4 mA and 13.5 V at 20 mA (HART), up to DC 35 V |
| Response time | 95 % of full scale within 500 ms for step changes |
| Ambient temperature | −40 to +60 °C; display readable −20 to +60 °C |
| Protection | IP66/67, Type 4X |
| Weight (DN 8 to 80) | Aluminium housing 9 / 10 / 12 / 17 / 28 / 53 kg; stainless 316L housing 11.5 / 12.5 / 14.5 / 19.5 / 30.5 / 55.5 kg |
How a loop-powered Promass F 200 works
Two parallel bent tubes vibrate in antiphase at resonance. Flowing fluid causes a phase shift between inlet and outlet pickups proportional to mass flow, while the resonance frequency gives density and the tube temperature is used for compensation. The transmitter is powered from the same pair of wires that carries the 4-20 mA signal, so the minimum supply voltage at the terminals depends on the output current and the loop load. For FOUNDATION Fieldbus and PROFIBUS PA the minimum terminal voltage is 9 V with a 32 V maximum. Plan the safety barrier, cable and receiver resistance against these figures.
Connections, materials and hazardous areas for the Promass F 200
Connection types include EN 1092-1 flanges, ASME B16.5 flanges, JIS B2220, DIN 11864-2 flanges, Tri-Clamp, DIN 11851, SMS 1145, ISO 2853 and DIN 11864-1 threads, and 8-VCO-4 or 12-VCO-4 couplings, with optional NAMUR installation lengths to NE 132. The measuring tube can be chosen in three grades, which is the main reason to pick the Promass F 200 over lower-cost models when the fluid is aggressive. Ex-certified versions are covered by separate Endress+Hauser safety instructions and must be matched to your zone; the family can be used for flow monitoring up to SIL 2 single-channel and SIL 3 with redundancy where the functional-safety option is ordered.
Where the Promass F 200 sits in the Promass range
Compared with the Promass E 300, the Promass F 200 gives a tighter accuracy class and a wider material choice, but it is loop-powered with fewer I/Os instead of the Proline 300 multi-I/O approach. The Promass P 100 serves hygienic single-tube duty up to DN 50, the Promass H 300 handles highly corrosive media with tantalum or zirconium tubes, and the Promass A 300 covers very small flows.
Selection checklist for the Promass F 200
- Fluid compatibility to choose 904L, 316L or Alloy C22 tubes.
- Flow range per size and whether the extended density option is useful for density-based products.
- Process temperature, to choose between the standard (+150 °C) and extended (+205 °C) version.
- Connection, pressure class and, for replacements, NAMUR length.
- Output code (A, B, C, E or G) and loop supply capability.
- Zone marking, SIL and certificate requirements.
Installation, commissioning and maintenance of the Promass F 200
Avoid mounting where gas can collect in the tubes and keep static pressure sufficient to avoid cavitation. No inlet or outlet run is needed. Wire the loop with attention to cable resistance and the supply voltage figures above, perform a zero adjustment at standstill with the line full, and configure through the display, a service interface, FieldCare or DeviceCare. Heartbeat Technology provides verification and monitoring where the application package is ordered.
Typical applications of the Promass F 200 in Oman and the GCC
Loop-powered Coriolis meters are popular for upgrading existing 4-20 mA wiring in refineries, gas processing, LNG and chemical plants. They are used in fuel and solvent loading, additive and chemical injection, steam-heated lines within the temperature limit, and in power and desalination utilities. In summer, shade the transmitter housing and respect the +60 °C ambient limit.
Information to send with your RFQ
- Existing nameplate or order code.
- Fluid, density, viscosity, flow, pressure, temperature.
- Line size, connection standard and installation length.
- Output code, loop supply and zone marking.
- Certificates and SIL or Ex documents required.
Documents and quotation
The Endress+Hauser Technical Information for the Promass F 200 is attached on this page as a datasheet. Send the part number and your duty data and we will confirm configuration, lead time and availability for Oman and the GCC.
Other Models in the Eh Promass Coriolis Range
Seven Star LLC supplies models from the Eh Promass Coriolis range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser Promass P 100 Hygienic Coriolis Flowmeter | Flowmeters | View details |
| Endress+Hauser Promass A 100 Low-Flow Coriolis Flowmeter | Flowmeters | View details |
| Endress+Hauser Promass A 300 Coriolis Mass Flowmeter | Flowmeters | View details |
| Endress+Hauser Promass E 300 Coriolis Mass Flowmeter | Flowmeters | View details |
| Endress+Hauser Promass F 200 Loop-Powered Coriolis Flowmeter | Flowmeters | You are viewing this model |
| Endress+Hauser Promass H 300 Corrosion-Resistant Coriolis Meter | Flowmeters | View details |
Datasheets & Documents
- Datasheet Endress+Hauser Promass F 200 Technical Information Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser Promass F 200 Loop-Powered Coriolis
Answers from our engineering team on installation, compatibility and integration.
01Is the Promass F 200 loop-powered?
Yes. The transmitter takes its power from the 4-20 mA loop, with a minimum terminal voltage of 17.9 V at 4 mA and 13.5 V at 20 mA, up to a maximum of 30 or 35 V depending on the output option.
02What accuracy does the Promass F 200 offer?
Liquid mass and volume flow accuracy is ±0.10 % of reading, gas mass flow is ±0.25 %, and density is ±0.0005 g/cm³ under reference conditions.
03Which fieldbus outputs does the Promass F 200 have?
Output options are 4-20 mA HART, HART with pulse/frequency/switch, HART with a second 4-20 mA, FOUNDATION Fieldbus and PROFIBUS PA, selected by order code.
04What temperature can the Promass F 200 measure?
The standard version covers −50 to +150 °C and the extended version up to +205 °C, selected through the measuring tube material option.
05Which tube materials are offered for the Promass F 200?
Measuring tubes are available in 1.4539 (904L), 1.4404 (316/316L) or Alloy C22 (2.4602), with connections in 1.4404, 1.4301 or Alloy C22.