- Automation & ControlView all 3,055 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: AMETEK
AMETEK Land Cyclops L Portable Non-Contact Pyrometer
Description
Overview
The AMETEK Cyclops L is a family of portable, non-contact infrared pyrometers from AMETEK Land for accurate temperature measurement of hot targets from 200 to 3000°C (392 to 5432°F). Land states that the Cyclops series sets the industry standard for high-quality portable pyrometers. The instrument uses through-the-lens sighting, so the operator sees exactly the target being measured, and its single-handed ergonomic design allows measurements in harsh environments. High-quality, fully focusable lenses give small spot sizes at any distance, and on-board data logging stores readings directly in the instrument.
Seven Star LLC supplies the AMETEK Cyclops L models and accessories to refineries, petrochemical plants, steel and aluminium smelters, cement plants, glass works and power stations in Oman and the GCC. Our Muscat team helps choose the right model and wavelength for the application, and we provide model selection support from Muscat.
The AMETEK Cyclops L Models
- C055L: 1000 to 2000°C, nominally 0.55 µm, with the advanced Meltmaster mode, fixed focus and a parallel 28 mm target spot to 5 m. Intended for molten metal pouring streams.
- C100L: 600 to 3000°C (displayed from 550°C), 1 µm with advanced spectral filtering, 180:1 circular field of view, focusing from 1 m to infinity.
- C160L: 200 to 1400°C, 1.6 µm with advanced spectral filtering, 180:1 circular field of view, accuracy 0.25 %K plus 2°C.
- C390L: 450 to 1400°C, nominally 3.9 µm, 180:1 square field of view. This wavelength is commonly used to see through flames and combustion gases in fired heaters and reformers.
Measurement Functions
The AMETEK Cyclops L offers four trigger and logging modes: single (classic), latch, burst and route. When the trigger is pressed, processed values including peak, continuous, average and valley are displayed in real time. Emissivity can be set from 0.10 to 1.20 in 0.01 steps, measurement resolution is 0.1°C or 1°F, and repeatability is 1°C (2°F). Response time is 30 ms for the C055L, C100L and C160L, and 500 ms to 98 percent for the C390L. Accuracy is listed as 0.5 %K for the C055L and C390L and 0.25 %K for the C100L.
The AMETEK Cyclops L optical system provides a 9 degree field of view with an eyepiece adjustable from −3.75 to +2.5 diopters. On the C100L and C160L, optional close-up lenses allow focus down to 215 mm, giving minimum target sizes as small as 0.4 to 0.5 mm. Without close-up lenses, the minimum target is 5 mm at 1 m.
Data Logging and Connectivity
Each AMETEK Cyclops L logs up to 9999 readings and 9 routes internally, eliminating the need for a separate recording device. Standard Bluetooth and USB connectivity allow periodic download or live streaming to a mobile device or PC. Land’s free Cyclops logger software shows current readings, a table view and a trend view, and an Android data logger app is available. For inspection teams, route mode is useful because it guides the operator through a fixed sequence of measurement points, such as the tubes of a fired heater, and stores the results in order.
Construction and Accessories
The rugged casing protects against heat, bumps and drops. The AMETEK Cyclops L weighs 0.83 kg (1.8 lb), operates from 0 to 50°C ambient, is sealed to IP40, and is powered by one MN1604 / 6LR61 / PP3 battery or USB. Standard accessories are a lens cap, protection window or filter, battery, wrist strap, USB cable and heat protection jacket. Optional accessories include close-up lenses, a waterproof carry case, a long eye relief eyepiece for use with goggles or face shields, and neutral density filters for the C100L to improve contrast on very bright targets. Traceable calibration is available.
Applications in Oman and the GCC
- Fired heater and steam reformer tube wall temperature surveys with the C390L.
- Furnace and kiln refractory and shell checks.
- Molten aluminium and steel pouring temperature with the C055L.
- Glass production, forging and heat treatment.
- Cement kiln burning zone and clinker checks.
In refineries and petrochemical plants the pyrometer is part of a wider combustion and process monitoring toolkit that may include the AMETEK Thermox WDG-V flue gas oxygen analyzer, the AMETEK 3050-OLV moisture analyzer and the AMETEK 5100P transportable TDLAS analyzer.
Good Measurement Practice (General Guidance)
The following points are general guidance rather than Land data. Choose the wavelength to suit the target: shorter wavelengths reduce errors from unknown emissivity on hot metals, while 3.9 µm is selected to view tube surfaces through furnace flames. Set emissivity from a reference measurement where possible, keep the lens clean, and make sure the target fills the measurement spot. Record readings in route mode to compare surveys over time, and send the AMETEK Cyclops L for calibration at the interval set by your quality system.
Why Use a Portable Pyrometer (General Guidance)
This section is general background rather than Land data. Fixed thermocouples show the temperature at only a few points and can drift or fail in hot, corrosive service. A portable AMETEK Cyclops L lets an inspector survey many points quickly without contact, which is valuable for hot spots on furnace tubes, refractory linings and process equipment that cannot be reached safely. Regular surveys with the AMETEK Cyclops L help operators run heaters closer to design limits, detect coking or flame impingement early, and plan maintenance with real data. The same instrument can then be used on other plant equipment, which spreads the cost of the investment across several departments.
Technical Specifications
| Parameter | AMETEK Cyclops L (Land specification sheet) |
|---|---|
| Models and ranges | C055L 1000-2000°C; C100L 600-3000°C; C160L 200-1400°C; C390L 450-1400°C |
| Spectral response | 0.55 µm; 1 µm; 1.6 µm; 3.9 µm |
| Field of view | 9 degree optical; 180:1 measurement (C100L, C160L, C390L) |
| Emissivity | 0.10 to 1.20 in 0.01 steps |
| Data logging | 9999 readings and 9 routes; Bluetooth and USB |
| Repeatability | 1°C (2°F) |
| Operating temperature | 0 to 50°C |
| Power | PP3 battery or USB |
| Weight / sealing | 0.83 kg; IP40 |
How to Order
To order the AMETEK Cyclops L, tell Seven Star LLC the target material, temperature range, measuring distance and whether you need close-up lenses or filters. Our Muscat team will recommend the model and prepare a formal quotation. The Land brochure and specification sheet can be downloaded from this page, and we provide model selection support from Muscat for customers across Oman and the GCC.
See also: AMETEK Land SPOT+ Series Smart Industrial Pyrometers; AMETEK 173434 Stainless Steel Pressure Snubber, 1/4 NPT Gas; AMETEK 173429 Brass Pressure Snubber, 1/4 NPT Liquid.
Datasheets & Documents
- Brochure AMETEK Land Cyclops L Portable Industrial Pyrometer Brochure and Specification Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK Land Cyclops L Portable Non-Contact Pyrometer
Answers from our engineering team on installation, compatibility and integration.
01What temperature range does the AMETEK Cyclops L cover?
Across the family, 200 to 3000 degrees C: C160L from 200 to 1400, C390L from 450 to 1400, C100L from 600 to 3000 and C055L from 1000 to 2000 degrees C.
02Which model is used for fired heater tubes?
The C390L operates at nominally 3.9 micrometres, a wavelength commonly chosen for measuring tube walls through furnace flames.
03Can the Cyclops L store readings?
Yes. It logs up to 9999 readings and 9 routes internally and transfers data by Bluetooth or USB to the free logger software or an Android app.
04What powers the instrument?
One MN1604 / 6LR61 / PP3 battery or a USB connection.
05Does Seven Star LLC supply the AMETEK Cyclops L in Oman?
Yes. Seven Star LLC supplies AMETEK Cyclops L pyrometers and accessories in Oman and the GCC, from our office in Muscat.


















Reviews
There are no reviews yet.