- Automation & ControlView all 2,897 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Hydac
Hydac EDS 3400 Electronic Pressure Switch with Digital Display
Description
Overview
The Hydac EDS 3400 is a compact electronic pressure switch for relative pressure measurement in the high-pressure range. A stainless steel measuring cell with a thin-film strain gauge converts system pressure into an electrical signal, and a built-in four-digit display shows the value locally so that a technician can read the pressure without connecting a separate gauge. The instrument offers one or two switching outputs and, in its extended versions, an additional switchable analog output, which lets a single device handle limit switching and continuous monitoring on the same measuring point.
Seven Star LLC supplies the Hydac EDS 3400 to hydraulic power units, pneumatic systems and refrigeration plants across the Sultanate of Oman and the wider GCC, with engineering support in Muscat. The Hydac EDS 3400 datasheet quoted on this page is the manufacturer document for the US catalog edition, which states ranges in psi, so buyers who need bar or MPa ranges can request a quotation against the metric part number and confirm the exact order code with our team before purchase.
Operating Principle
The pressure port of the Hydac EDS 3400 carries the medium directly onto a stainless steel diaphragm that carries a thin-film strain gauge. When pressure deflects the diaphragm, the resistance of the bridge changes in proportion to the applied pressure, and the on-board electronics condition and temperature-compensate the signal over a compensated range of 14 to 158 °F. The manufacturer states an accuracy of ≤ ±0.5 % of full scale (typical) according to DIN 16086, a repeatability of ≤ ±0.25 % and a long-term drift of ≤ ±0.3 % per year, figures that matter on machines which run for thousands of hours between calibrations.
The measured value in the Hydac EDS 3400 is compared with the programmed switching points in a microprocessor, and the result drives PNP transistor outputs that can carry up to 1.2 A each with a reaction time below 10 ms. Each output of the Hydac EDS 3400 can work as a switch-point function or as a window function, can be set to normally open or normally closed, and can be delayed on switch-on or switch-off between 0.00 and 99.99 seconds. A display filter smooths the readout under pressure pulsation, and the peak value of the pressure can be recalled on the display, which helps when commissioning pumps and accumulators that generate short pressure spikes.
Engineering Design of the Hydac EDS 3400
A distinctive feature of the Hydac EDS 3400 is that the display head can be moved in two planes. The Hydac EDS 3400 can therefore be installed in almost any position, and the display can still be turned toward the operator without a mechanical adapter, which saves fitting time on crowded manifolds and valve blocks. The process connection is a 9/16-18 UNF 2A (SAE 6 male) thread tightened to 15 lb-ft (20 Nm), the wetted parts are stainless steel with an FPM seal, and the electrical connection is an M12x1 male connector, 4-pole for outputs 1, 2 and 3 or 5-pole for the version with two switching outputs plus analog output.
The Hydac EDS 3400 housing is rated IP 67 according to IEC 60529, and the manufacturer specifies vibration resistance up to 10 g between 10 and 500 Hz and shock resistance up to 50 g for 11 ms. The unit has over-voltage, override and short-circuit protection, and a programming lock prevents accidental changes after commissioning. All settings are grouped in two short menus, so a technician can adjust switch points, hysteresis, delays and the unit of measurement (bar, psi or MPa) with the three keys on the front, and the instrument converts the switching settings automatically when the unit is changed.
Key Features
The Hydac EDS 3400 packs measurement, local indication and switching into one compact housing. Its main capabilities are listed below:
- Compact stainless steel measuring cell with thin-film strain gauge for relative pressure in four ranges from 1000 to 9000 psi.
- One or two PNP transistor switching outputs rated up to 1.2 A each, with a reaction time below 10 ms.
- Optional switchable analog output of 4 .. 20 mA or 0 .. 10 V for PLC supervision of the same measuring point.
- Four-digit LED display that can be rotated in two planes and shows pressure in bar, psi or MPa.
- Accuracy of ≤ ±0.5 % of full scale typical, with repeatability of ≤ ±0.25 % of full scale.
- Switch points, hysteresis, window function, switching direction and on/off delays adjustable from the front keys.
- Display of actual pressure, peak value or switch points, with a display filter for pulsating pressure.
- IP 67 housing with M12x1 connector and an optional DESINA-compliant pin configuration with diagnostic signal.
Industrial Applications
The Hydac EDS 3400 is aimed at hydraulics and pneumatics, and the manufacturer also lists refrigeration and air conditioning technology as a main field. In Oman the Hydac EDS 3400 therefore appears in hydraulic power units on drilling and workover equipment, press and lifting systems in fabrication yards at Sohar and Duqm, tank-farm valve actuation, and accumulator stations that need a pressure limit switch with local indication. The 1000 to 9000 psi ranges cover everything from lubrication and pilot circuits up to high-pressure test benches and accumulator charging circuits.
Because the Hydac EDS 3400 combines a switching output with an optional analog signal, maintenance teams in the GCC can wire it directly into a PLC input for supervision while the local display supports fault finding on site. Buyers who compare electronic switches can also review the WIKA PSM01 compact pressure switch or the United Electric One Series 1XSWLL pressure switch in our catalog, and mechanical differential applications are covered by the CCS 646DZE differential pressure switch. Seven Star LLC can help select the correct range, output option and connector for each circuit so that the overload and burst ratings of the chosen version stay well above the highest pressure peak in the system.
Technical Specifications
Key parameters of the Hydac EDS 3400 taken from the manufacturer datasheet (US catalog edition):
| Parameter | Specification |
|---|---|
| Model | Hydac EDS 3400 |
| Measuring ranges | 1000, 3000, 6000 and 9000 psi (relative pressure) |
| Overload pressure | 2900, 7250, 11600 and 14500 psi |
| Burst pressure | 7250, 14500, 29000 and 29000 psi |
| Mechanical connection | 9/16-18 UNF 2A (SAE 6 male), 15 lb-ft (20 Nm) torque |
| Wetted parts | Stainless steel connection, FPM seal |
| Accuracy (DIN 16086) | ≤ ±0.5 % FS typical; ≤ ±1 % FS maximum setting accuracy of display and analog output |
| Repeatability | ≤ ±0.25 % FS maximum |
| Long-term drift | ≤ ±0.3 % FS typical per year |
| Temperature drift | ≤ ±0.014 % per °F maximum (zero point and range) |
| Switching outputs | 1 or 2 PNP transistor outputs, max. 1.2 A each, more than 100 million switching cycles |
| Reaction time | < 10 ms |
| Analog output (optional) | Selectable 4 .. 20 mA (load max. 500 Ω) or 0 .. 10 V (load min. 1 kΩ) |
| Supply voltage | 9 .. 35 V DC without analog output; 18 .. 35 V DC with analog output |
| Current consumption | Max. 35 mA, or 55 mA with analog output (switching outputs inactive) |
| Display | 4-digit red 7-segment LED, 7 mm digit height; bar, psi or MPa |
| Compensated temperature range | 14 .. 158 °F |
| Operating / fluid temperature | -13 .. +176 °F (-13 .. +140 °F according to UL specification) |
| Storage temperature | -40 .. +176 °F |
| Vibration / shock resistance | ≤ 10 g at 10 .. 500 Hz (DIN EN 60068-2-6) / ≤ 50 g, 11 ms (DIN EN 60068-2-29) |
| EMC | EN 61000-6-1 / 2 / 3 / 4 |
| Protection class | IP 67 (IEC 60529) |
| Electrical connection | M12x1 male, 4-pole (outputs 1, 2, 3) or 5-pole (output 5); DESINA-compliant version available |
| Weight | approx. 120 g |
Request a Quote for Hydac EDS 3400
To request a quotation for the Hydac EDS 3400, check current availability and lead time or download the manufacturer datasheet from the document tab on this page, contact the instrumentation team at Seven Star LLC with your required pressure range, output version and connector. We supply the Hydac EDS 3400 to industrial and oil and gas customers in Oman and the GCC and can support selection, commissioning questions and repeat orders.
Other Hydac models from Seven Star LLC: Hydac ETS 1700 electronic temperature switch, Hydac RFM return line filter and Hydac SB330 bladder accumulator.
Datasheets & Documents
- Datasheet Hydac EDS 3400 Datasheet (US edition, psi) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac EDS 3400 Electronic Pressure Switch with
Answers from our engineering team on installation, compatibility and integration.
01What does the Hydac EDS 3400 electronic pressure switch do?
The Hydac EDS 3400 measures relative pressure with a stainless steel thin-film cell, shows it on a four-digit LED display and switches one or two PNP outputs when programmed limits are reached. An optional analog output of 4 .. 20 mA or 0 .. 10 V can be selected in the extended versions.
02Which pressure ranges and connection does the Hydac EDS 3400 offer?
The datasheet lists measuring ranges of 1000, 3000, 6000 and 9000 psi with overload pressures of 2900, 7250, 11600 and 14500 psi. The mechanical connection is 9/16-18 UNF 2A (SAE 6 male), and the electrical connection is an M12x1 male connector with four or five poles depending on the output model.
03Can the display and the switching behaviour be adjusted on the Hydac EDS 3400?
Yes. The display can be turned in two planes, and the unit can be switched between bar, psi and MPa. Switching points, hysteresis, switch-point or window function, N/O or N/C direction and delays between 0.00 and 99.99 seconds are adjustable, and a programming lock protects the settings.
04Is the Hydac EDS 3400 suitable for harsh machine environments?
The housing is rated IP 67, vibration resistance is up to 10 g at 10 to 500 Hz and shock resistance is up to 50 g. The operating temperature range is -13 to +176 °F (-13 to +140 °F according to the UL specification), so the user should check the actual fluid and ambient temperature of the installation against these limits.
05Where can I source the Hydac EDS 3400 in Oman?
Seven Star LLC supplies the Hydac EDS 3400 to customers in Oman and the GCC, with engineering support in Muscat. Send the required range, output version and connector with your request for quotation, and our team will confirm the order code and availability.


















Reviews