Endress+Hauser Levelflex FMP55 Interface Guided Radar Transmitter

Description

Overview of the Endress+Hauser Levelflex FMP55 Interface and Level Radar

The Endress+Hauser Levelflex FMP55 is a guided wave radar built for level and interface measurement in liquids. Its distinguishing feature is a PFA-coated probe combined with a capacitance measurement, which allows it to locate the boundary between two liquids such as oil on water even when an emulsion layer forms between them. The transmitter is offered with a rod probe up to 4 m, a rope probe up to 10 m or a coaxial probe up to 6 m, covers a process range of –50 to +200 °C and –1 to +40 bar, and achieves ±2 mm in level measurement.

As the official trusted supplier and regional supplier for Endress+Hauser, Seven Star LLC proudly supplies the Endress+Hauser Levelflex FMP55 to customers across the Sultanate of Oman and the wider GCC. Seven Star LLC can supply the Technical Information TI01003F with each offer so that process engineers in Muscat, Sohar and Salalah can check probe coating, flange and interface conditions before ordering.

Interface Measuring Principle of the Endress+Hauser Levelflex FMP55

The Endress+Hauser Levelflex FMP55 is a downward-looking time-of-flight (ToF) system, also called time domain reflectometry. High-frequency pulses run down the probe and are reflected at the product surface, and the distance follows from D = c · t/2. In interface measurement, a part of the pulse enters the upper medium of low permittivity and is reflected again at the boundary to a lower medium of higher permittivity, so the delayed time-of-flight through the upper layer yields the interface position as well as the total level.

In addition, the FMP55 measures the capacitance of the probe. This is what keeps interface readings available when emulsions or rag layers weaken the second echo. The manufacturer lists conditions for this mode: the relative permittivity of the upper medium must be known, constant and not above 10, the permittivity difference between the media must exceed 10, the upper layer must be at least 60 mm thick, and the capacitive evaluation expects an upper-medium conductivity below 1 µS/cm and a lower-medium conductivity above 100 µS/cm.

Engineering Design of the Endress+Hauser Levelflex FMP55

The probe options match the vessel. The 16 mm PFA-coated rod probe over 316L reaches 4 m with a flexural strength of 30 Nm, the 4 mm PFA-coated rope probe over 316 reaches 10 m with a tensile loading capacity of 2 kN, and the 316L coaxial probe of 42.4 mm diameter with multiple holes reaches 6 m with 300 Nm flexural strength. Coaxial probes are unaffected by nozzles and internal fixtures and give maximum EMC protection in plastic tanks. A remote probe version with a separate sensor is available for probe lengths up to 7 m.

The process connection is a flange. The electronics sit in a plastic GT19, aluminum GT20 or stainless steel GT18 housing, weighing about 1.2 kg, 1.9 kg and 4.5 kg, with the probe adding about 1.2 kg per meter plus the flange. A two-wire loop needs 17.5 to 35 V in non-hazardous areas, and outputs are 4–20 mA HART, PROFIBUS PA and FOUNDATION Fieldbus, with optional Bluetooth for the SmartBlue app. A 32-point linearization converts level to volume or mass, and HistoROM stores configuration and measured values.

Key Features of the Endress+Hauser Levelflex FMP55

The Endress+Hauser Levelflex FMP55 brings the following documented capabilities to level and interface duties:

  • Interface measurement with capacitance evaluation that tolerates emulsion layers between two liquids.
  • Level accuracy of ±2 mm up to 10 m, and interface accuracy of ±10 mm above 500 mm measuring distance.
  • Step response below 0.8 s for level and below 2.2 s for interface measurement with probes under 10 m.
  • Process temperature from –50 to +200 °C with fully coated probes and pressure from –1 to +40 bar.
  • Rod, rope and coaxial probes with a maximum of 4 m, 10 m and 6 m respectively.
  • SIL 2 according to IEC 61508 and SIL 3 with homogeneous redundancy, with easy proof testing.
  • International explosion protection certificates, marine approval and EN 10204-3.1 material certificates.
  • Multi-Echo Tracking, mapping of interference echoes and Heartbeat Technology for diagnostics.

Industrial Applications of the Endress+Hauser Levelflex FMP55

The Endress+Hauser Levelflex FMP55 suits separators, decanters and settling tanks where oil, condensate or solvent floats on water, and storage vessels holding corrosive liquids that attack bare stainless steel probes, since the PFA coating protects the probe. In Oman this fits oil-water separation at upstream and midstream facilities, slop tanks and effluent treatment at refineries, and chemical storage in the Sohar and Salalah industrial zones where acids, caustic or aggressive solvents are handled.

In Oman and the GCC, Seven Star LLC supplies the Levelflex family to customers in Oman and the GCC. For uncoated duties engineers can compare the Endress+Hauser Levelflex FMP51 and the Levelflex FMP54 guided radar, and for basic tanks the

Endress+Hauser Levelflex FMP50

.

Technical Specifications of the Endress+Hauser Levelflex FMP55

The table lists the main data of the Endress+Hauser Levelflex FMP55 as published in Endress+Hauser Technical Information TI01003F.

Parameter Specification
Model Endress+Hauser Levelflex FMP55
Measuring principle Guided wave radar (ToF) with capacitance interface measurement
Probe types and maximum length Rod 4 m (PFA > 316L); rope 10 m (PFA > 316); coaxial 6 m (316L)
Process connection Flange
Process temperature –50 to +200 °C
Process pressure –1 to +40 bar
Accuracy, level ±2 mm (distance up to 10 m)
Accuracy, interface ±20 mm up to 500 mm; ±10 mm above 500 mm
Outputs 4–20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Supply voltage (2-wire HART, non-Ex) 17.5 to 35 V
Functional safety SIL 2; SIL 3 with homogeneous redundancy

Ordering details for FMP55

For an FMP55 interface measurement, identify both liquids and whether an emulsion layer forms between them. Specify rod, rope or coaxial construction and the flange size and rating before matching the ordered probe.

Technical reference

Request a Quote for Endress+Hauser Levelflex FMP55

To specify the Endress+Hauser Levelflex FMP55, send Seven Star LLC the two media, their permittivity and conductivity, the vessel height, the flange and the pressure so that we can prepare a formal RFQ. The Technical Information TI01003F can be downloaded from this page, and our instrumentation division will confirm probe and coating options and lead time at quotation. In Oman and the GCC, we supply the Endress+Hauser Levelflex FMP55 with manufacturer documentation and local support.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser Levelflex FMP55 Technical Information (TI01003F) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser Levelflex FMP55 Interface Guided

Answers from our engineering team on installation, compatibility and integration.

01What is the Endress+Hauser Levelflex FMP55 used for?
It is a guided wave radar for level and interface measurement in liquids, for example the boundary between oil and water in separators and storage vessels.
02How does the Levelflex FMP55 measure an interface with emulsions?
In addition to the time-of-flight echo, it measures the capacitance of the probe, so interface readings remain available when an emulsion layer weakens the second reflection.
03Which probe types and lengths are available for the FMP55?
A PFA-coated rod probe up to 4 m, a PFA-coated rope probe up to 10 m and a 316L coaxial probe up to 6 m, with a flange process connection.
04What process temperature, pressure and accuracy does the FMP55 offer?
The process temperature range is -50 to +200 °C, the pressure range is -1 to +40 bar, and level accuracy is ±2 mm for distances up to 10 m.
05Is Seven Star LLC a trusted supplier for Endress+Hauser products?
Yes. Seven Star LLC is a trusted supplier of Endress+Hauser products, supplying instrumentation across Oman and the GCC, with genuine documentation and local technical support.