Victaulic Series 723 is a three-port diverter ball valve in a single 2 inch (DN50) size. Its inlet is at the bottom of the body and the two outlets are to the left and right, so turning the stem sends the flow 90 degrees to either side. A 180 degree ball is available as an option for duties that need a straight-through and a side path instead. The body is ductile iron to ASTM A536 Grade 65-45-12 in black enamel, the ball and stem are Type 316 stainless steel and the seats and seals are reinforced TFE.

All three ports are grooved for Victaulic couplings, which means the valve drops into a grooved pipe system without flanges or threads. The maximum working pressure in the datasheet is 600 psi (4135 kPa).

Seven Star LLC is an independent supplier serving Oman and the GCC.

Technical data for Victaulic Series 723

Parameter Value
Valve type Three-port diverter ball valve, bottom inlet
Size 2 inch / DN50, actual outside diameter 2.375 inch / 60.3 mm
Maximum working pressure 600 psi / 4135 kPa
Body Ductile iron ASTM A536 Grade 65-45-12, black enamel; optional fusion bonded epoxy
Ball and stem Type 316 stainless steel, 90 degree turn; optional 180 degree turn
Seats and seals Reinforced TFE, rated to +450 F / +232 C
Stem nuts and washers Electrogalvanized steel
Operator Stamped carbon steel handle, electrogalvanized, plastic grip
Operator options Bare stem, two-position handle, two-position handle with tamper-resistant locking device
Flow coefficient, full open Cv 36 / Kv 31
Face dimension A 6.50 inch / 165 mm
Overall height, dimension J 9.13 inch / 232 mm
Approximate weight 7.5 lb / 3.4 kg
Order numbering example B-020-6676-15 (type, size, pressure code, body, ball, seat, operator)

How the three ports work

With the bottom port as the inlet, a 90 degree ball turn aims the flow to the left outlet or the right outlet. It never opens to both at once, so the valve is a true diverter rather than a mixing or splitting tee. The optional 180 degree ball changes the geometry so the flow can be switched between two opposite directions. In either form the two-position handle clearly shows which branch is open, and the locking handle version stops casual tampering with the route.

A flow coefficient of Cv 36 at full open lets a designer size the pressure drop from the standard formula, flow equals Cv times the square root of the pressure drop, so a 2 inch line passing 60 gallons per minute loses about 2.8 psi across the valve in the open path.

Where it is used

Diverter valves fit chilled and hot water plants, where a pump can feed one of two heat exchangers or one of two coils; compressed air and cooling water skids that choose between a duty and a standby branch; and process packages that route fluid to bypass or return lines. In utility buildings across Oman a single 2 inch diverter replaces two isolation valves and a tee, saving space and the risk of both legs being open.

Selection notes for Victaulic Series 723

Specify the body coating and the ball turn at the order stage: black enamel with a 90 degree ball is standard, while fusion bonded epoxy and 180 degree balls are options on request. Choose the operator based on the service: a bare stem for actuator mounting, the two-position handle for routine plant use, or the locking handle where tampering has to be prevented. The valve end connections are grooved, so your pipe must be grooved to the Victaulic groove specification and gaskets must be chosen for the fluid.

The seat material is rated to 450 degrees Fahrenheit, but the datasheet warns that the actual fluid temperature and service may be governed by the gaskets of the couplings used for installation.

How Series 723 differs from other Victaulic ball valves

Series 721 and 722 are two-port ball valves for isolation, and Series 726 is a stainless steel valve for process media. Victaulic Series 723 is the only one in this group with three ports and a diverting action, available only in 2 inch and rated to 600 psi.

Installation and commissioning

Depressurise and drain the piping system, wear safety glasses, hard hat and foot protection, and install the grooved couplings over the three pipe ends following the field installation handbook. Support the valve body so that the handle weight and pipe load do not pull on the couplings. Cycle the handle through its stops before filling the line to confirm the correct positions and the direction of diversion.

Maintenance

Operate the valve periodically so the seats do not stick. Look for leakage at the stem and at the three coupling joints, and replace gaskets whenever a coupling is opened. If a diverter shows internal leakage, replace the valve rather than leave a doubtful isolation point in the line.

Design considerations for diverter circuits

When a diverter feeds two parallel branches, think about what happens during the stroke. The ball moves through intermediate positions where flow may be restricted, so pumps should not be deadheaded in the transition. Where one branch contains a pump and the other a bypass, check that the pump curve can tolerate the changeover. Piping on the outlet side should be supported separately, because grooved joints carry little bending load and the valve handle adds torque when it is operated.

In heat recovery layouts the diverter is often placed ahead of two heat exchangers and a three-way control action is not needed, since a simple selection between two paths is enough. In such a case a two-position handle is sufficient and an actuator can be fitted later because the bare stem option is available.

Related items you may also need: Victaulic Style 07 Zero-Flex Rigid Coupling | Victaulic Style 77 Standard Flexible Coupling | Victaulic FireLock Series 705 Butterfly Valve, Supervised Open | All Victaulic products.

Victaulic Series 723 ordering checklist

  • When the Victaulic Series 723 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
  • Every enquiry for the Victaulic Series 723 is answered with a written confirmation of the code, condition and expected lead time.
  • Use the attached datasheet to check the Victaulic Series 723 ratings, dimensions and connection details against your drawings.
  • We supply the Victaulic Series 723 as part of our ball valves range to plants in Oman and the GCC.
  • For critical duty, keeping one Victaulic Series 723 as a site spare shortens downtime after a failure.

Documents and quotation

The manufacturer datasheet for Victaulic Series 723, publication 08.13, is attached. Send your RFQ with the valve code from the numbering system, quantity and operator option, and we will confirm the details before quoting.

Datasheets & Documents
  • PDF Datasheet Victaulic Series 723 Three-Port Diverter Ball Valve 2 inch DN50 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Victaulic is an American maker of grooved mechanical pipe joining systems, valves and fire protection products, headquartered in Easton, Pennsylvania. Its grooved coupling was patented in 1919 by Ernest Tribe, and the name combines 'victory' and 'hydraulic'. Victaulic is privately held and reinvests in its own plants and technology.

Seven Star LLC lists Victaulic couplings and butterfly valves, among them the Style 107N QuickVic rigid coupling, and supplies Victaulic couplings and fittings for mechanical, utility and process piping in Oman on inquiry.

Victaulic company profile

Origins 1919, grooved coupling patent
Name From 'victory' and 'hydraulic'
Headquarters Easton, Pennsylvania
Ownership Privately held
Product families Style 07, 77 and 107N grooved couplings, Vic-300 MasterSeal butterfly valves, FireLock fire protection valves and sprinklers, grooved fittings and tools

Milestones

  • 1919: The grooved Victaulic coupling is patented.
  • 2019: Victaulic marks 100 years.

Victaulic Style 107N QuickVic couplings

The Style 107N is a rigid coupling for roll-grooved or cut-grooved carbon steel and stainless steel pipe in sizes from 2 to 12 inches (DN 50 to DN 300). Victaulic rates it from full vacuum up to 750 psi (5171 kPa), but the working pressure of a given joint depends on pipe material, wall thickness and size. The housing has an angled bolt pad that makes the joint rigid, and a galvanized finish is optional.

Where Victaulic couplings are used and what to send

The manufacturer names HVAC, utility and process piping as the applications for this style. For an inquiry, send the style number, nominal size, pipe material and schedule, the fluid and temperature so the gasket grade can be checked, the housing finish and the quantity. GCC consultants often ask for the submittal sheet, which we provide from the manufacturer.

Facts checked against Victaulic's 100-year innovation timeline, October 2026.

Victaulic products we list

Family Examples
Pipes & Fittings Style 07 Zero-Flex Rigid Coupling, Style 107N QuickVic Rigid Coupling, Style 77 Standard Flexible Coupling
Fire Fighting FireLock Series 705 Butterfly Valve
Butterfly Valves Series 761 Vic-300 MasterSeal Butterfly…

FAQ

Questions about the Victaulic Series 723 Three-Port Diverter Ball Valve

Answers from our engineering team on installation, compatibility and integration.

01What size is Victaulic Series 723?
It is offered only in 2 inch (DN50), with grooved ends and an actual outside diameter of 2.375 inch (60.3 mm).
02What is the pressure rating of Series 723?
The datasheet gives a maximum working pressure of 600 psi (4135 kPa).
03What does the diverter do?
It has a bottom inlet and sends flow 90 degrees to the left or right outlet, and a 180 degree ball is available as an option.
04What operator options are offered for the 723?
Bare stem, two-position handle, or two-position handle with a tamper-resistant locking device.
05What is the flow coefficient of Series 723?
The datasheet lists Cv 36 (Kv 31) at full open for the 2 inch size.