Schneider Electric ZENL1111 1NO Contact Block

Description

ZENL1111: single NO contact block for Ø22 stations

The ZENL1111 is a Schneider Electric single contact block with one normally open (1 NO) contact and screw clamp terminals. It is rear mounted behind a 22 mm control or signalling unit, and the datasheet names the Harmony XAL and XAPS ranges as its home. Seven Star LLC supplies the ZENL1111 in Oman and the GCC as an independent supplier in Muscat, usually to maintenance stores that need the exact contact function back in a push-button or control station.

On the datasheet generated on 8 Nov 2026 the ZENL1111 is not marked as discontinued. It is sold in packs of five, so a request for one contact still means a pack, and stock should be confirmed before a repair depends on it.

Contact action of the ZENL1111

This block carries a normally open contact, which closes when the operator is pressed. The datasheet states that positive opening is not provided, which is normal for an NO contact because there is nothing to force open. The contact changes state after 2.6 mm of travel out of a total travel of 4.3 mm, with an operating force of 2.3 N and an operating torque of 0.05 N.m. The action is slow-break.

An NO block is the right choice for start, run and acknowledge functions, where the circuit should only be energised while or after the button is pressed. For stop functions a normally closed block such as ZENL1121 is the usual companion, and the two are often stacked in a single station.

Typical use of NO contacts in Oman and the GCC

Contact blocks like ZENL1111 are replaced during maintenance on control stations, XAPS pendants and push-button panels in oil and gas, power and water plants. Dust, heat and humidity attack contacts over years, and the 10 A thermal rating with silver alloy contacts suits typical 24 V DC and 230 V AC control circuits. Start and acknowledge circuits are a common place for it.

Environment and standards

The ZENL1111 is rated IP20, so it is a component that depends on its station for enclosure protection. Operating and storage temperatures both run from -40 to 70 °C, and the protective treatment code is TH. Vibration resistance is 5 gn from 12 to 500 Hz, and shock resistance is 30 gn for 18 ms and 50 gn for 11 ms. Standards listed are IEC 60947-1, IEC 60947-5-1, IEC 60947-5-4, IEC 60947-5-5, UL 508, CSA C22.2 No 14 and the JIS C8201 parts. Compare them with the project list before ordering ZENL1111.

Technical data of the ZENL1111

Parameter Specification
Manufacturer / part number Schneider Electric / ZENL1111
Range Harmony XAL; Harmony XAPS
Product type Contact block
Device short name ZENL
Destination For XB5 Ø 22 mm control and signalling units; For XAPS control station
Contacts type and composition 1 NO
Mounting of block Rear mounting
Assembly style For customer assembly
Contact operation Slow-break
Positive opening Without
Operating travel 2.6 mm (NO changing electrical state); 4.3 mm (total travel)
Operating force 2.3 N NO changing electrical state
Operating torque 0.05 N.m NO changing electrical state
Mechanical durability 10,000,000 cycles
Contact material Silver alloy (Ag/Ni)
Maximum resistance across terminals 25 MΩ
Short-circuit protection 10 A cartridge fuse type gG
Conventional thermal current [Ith] 10 A
Rated insulation voltage [Ui] 600 V, pollution degree 3
Rated impulse withstand [Uimp] 6 kV
Terminals Screw clamp terminals, ≤ 2 × 1.5 mm² with cable end; Screw clamp terminals, ≥ 1 × 0.22 mm² without cable end; 60947-1
Tightening torque 0.8–1.2 N.m
Net weight 0.015 kg
IP degree of protection IP20
Operating / storage temperature -40–70 °C for both
Vibration 5 gn, 12–500 Hz
Shock 30 gn for 18 ms; 50 gn for 11 ms
Standards IEC 60947-5-1, CSA C22.2 No 14, IEC 60947-1, UL 508, IEC 60947-5-5, JIS C8201-5-1, IEC 60947-5-4, JIS C8201-1
Sale per indivisible quantity 5

Switching ratings and life of the ZENL1111

The contact material is a silver alloy (Ag/Ni), and the maximum resistance across the terminals is 25 MΩ as stated on the datasheet. The conventional thermal current is 10 A and short-circuit protection is a 10 A gG cartridge fuse. Rated insulation voltage is 600 V in pollution degree 3, with a 6 kV impulse withstand. Mechanical durability is 10 million cycles.

Voltage Current Utilisation category
240 V 3 A AC-15, A600
120 V 6 A AC-15, A600
600 V 0.1 A DC-13, Q600
250 V 0.27 A DC-13, Q600
125 V 0.55 A DC-13, Q600
600 V 1.2 A AC-15, A600

The electrical durability entries are stated at one million cycles, for example AC-15 at 2 A and 230 V and DC-13 at 0.5 A and 24 V, at an operating rate below 3600 cycles per hour. The contact is also rated for dry-circuit duty, with a failure rate below 10-6 at 5 V and 1 mA in a clean environment.

Mounting the ZENL1111 in a station

The block is rear mounted and is assembled by the customer. The datasheet notes mounting on the integrated plate in the box, and the electrical composition codes SR1 (up to three blocks), SR2 (up to two blocks) and MR1 (up to two blocks) describe how many can be stacked. Terminals take up to two 1.5 mm² conductors with cable ends, or one 0.22 mm² or larger conductor without a ferrule, tightened to 0.8 to 1.2 N.m with a Philips or Pozidriv no 1 or a flat 4 or 5.5 mm blade.

Each block weighs 0.015 kg. After wiring, operate the head several times and check the contact with a meter before closing the station, because a block not fully latched on the plate gives intermittent contact. Replace this unit with a block of the same function, since swapping NO for NC reverses the logic of the circuit.

NO and NC blocks compared

ZENL1111 and ZENL1121 share the same body and terminals, and they differ in contact function and actuation figures.

Item ZENL1111 ZENL1121
Contact 1 NO 1 NC
Positive opening Without With, IEC 60947-5-1 appendix K
Travel at change of state 2.6 mm 1.5 mm
Operating force 2.3 N 2 N
Typical use Start, run, acknowledge Stop, interlock, fail-safe

Information to send with an RFQ for ZENL1111

The points below let us confirm the part number against the datasheet and check stock in one reply.

  • Part number this unit and quantity, noting the pack size of five.
  • The station or head type it goes into (XB5 head, XAL or XAPS).
  • Whether NO or NC is needed, and how many contacts are stacked.
  • Control voltage and current of the circuit it switches.
  • Photos of the existing block if the function is uncertain.
  • Delivery location.

Confirming NO or NC from the old block avoids a reversed circuit.

Documents and quotation

A copy of the Schneider Electric datasheet for the ZENL1111 is attached on this page for your technical file. It holds the electrical, mechanical and environmental values that are summarised above.

To request a quotation, send the part number and the quantity through the enquiry form and we will reply with availability and delivery terms. Seven Star LLC is an independent supplier and does not act for the manufacturer, so please compare the datasheet with your project requirements before you order.

Datasheets & Documents
  • PDF Datasheet Schneider Electric ZENL1111 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric ZENL1111 1NO Contact Block

Answers from our engineering team on installation, compatibility and integration.

01What contact does the ZENL1111 have?
One normally open contact with silver alloy (Ag/Ni) material. Positive opening is listed as not provided.
02What are the electrical ratings of the ZENL1111?
The conventional thermal current is 10 A, with ratings such as 3 A at 240 V AC-15 and 0.55 A at 125 V DC-13, and a 600 V insulation rating.
03How is the ZENL1111 mounted?
It is rear mounted on the integrated plate in the box of a 22 mm station and assembled by the customer. Terminals are screw clamp.
04Is the ZENL1111 discontinued?
The datasheet we hold does not mark it as discontinued, but stock should be confirmed. It is sold in packs of five.
05Does Seven Star LLC supply the ZENL1111 in Oman?
Yes. Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC. Send the part number and the quantity and we confirm availability and the documents we can provide.