Schneider Electric BMXDDI1602 X80 16-Input 24 V DC Module
Description
BMXDDI1602 Modicon X80 discrete input module: what it is and how the code reads
The BMXDDI1602 is a Schneider Electric product described in the datasheet as: Discrete input module, M340, 16 Inputs, 24 VDC sink. The BMXDDI1602 is a 16-channel discrete input module for the Modicon X80 platform, reading 24 V DC field signals into the controller. Seven Star LLC supplies the BMXDDI1602 in Oman and the GCC as an independent supplier based in Muscat.
Decoding the reference: BMX is the M340 / X80 platform, DDI the discrete DC input module type and 1602 the 16-channel, 24 V DC sink version. The datasheet title is Discrete input module, M340, 16 Inputs, 24 VDC sink.
Technical specifications of the BMXDDI1602
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / BMXDDI1602 |
| Description | Discrete input module, M340, 16 Inputs, 24 VDC sink |
| Range | Modicon X80 |
| Product type | Discrete input module |
| Application | Industrial Application |
| Discrete inputs | 16 isolated conforming to IEC 60947-5-2 at 24 V DC |
| Input voltage | 24 V DC, isolated |
| Input logic | Positive logic (sink) |
| Wiring mode | 2 or 3 wires |
| Input current | 3.5 mA at 24 V DC |
| Voltage state 1 guaranteed | >= 11 V |
| Voltage state 0 guaranteed | <5V |
| Current state 1 guaranteed | >= 2 mA |
| Current state 0 guaranteed | <= 1.5 mA |
| Input impedance | 6800 Ohm |
| Paralleling of inputs | Yes |
| Input protection | Reverse polarity protection |
| Typical response time | 4 ms |
| Maximum response time | 7 ms |
| Sensor power supply | 19 to 30 V |
| Current consumption | 76 mA DC |
| Power dissipation | 2.5 W |
| Isolation between channels and bus | 1500 V for 1 minute |
| Hot swapping | Yes |
| MTBF | 775000 H |
| Dimensions | 32 mm (W) x 103.7 mm (H) x 86 mm (D) |
| Net weight | 0.115 kg |
| Degree of protection | IP20 |
| Operating altitude | 0 to 2000 m; 2000 to 5000 m with derating |
| Marking | CE; UKCA; CULus; EAC; RCM |
How the BMXDDI1602 reads field signals
Each of the 16 channels is isolated and uses positive logic (sink), meaning the field device supplies the positive voltage to the input. The datasheet gives a guaranteed state 1 of >= 11 V and state 0 of <5V, an input current of 3.5 mA at 24 V DC and impedance of 6800 Ohm.
Typical response is 4 ms and maximum 7 ms. The module also evaluates the sensor supply: the datasheet lists a voltage detection threshold of < 14 V DC sensor fault; > 18 V DC sensor OK to flag a missing sensor supply.
Where the BMXDDI1602 fits in an X80 rack
The module sits in an X80 rack beside the processor (for example BMXP342020) and takes its logic power through the backplane, with the rack supplied by a power supply module such as BMXCPS2000. Field wiring uses the terminal connector and sensors can be 2- or 3-wire types.
Related discrete and analogue modules for the same rack include BMXAMI0410 analogue inputs; the TM3 range (TM3DI8, TM3DQ16T) serves the smaller M221/M241 controllers and is a different platform.
Selection and ordering checklist for the BMXDDI1602
- Confirm the sensors are 24 V DC and compatible with sink logic (PNP sensors normally suit sink inputs).
- Check the input current against sensor requirements and leakage currents.
- Count channels and spares; 16 per module.
- Check response time against the fastest signal; very fast pulses need a counter module.
- Confirm the module fits the rack (X80 platform) and slot.
- Plan wiring accessories: connector and cable set are separate items.
Installation, commissioning and maintenance of the BMXDDI1602
Insert the module in its slot with power off or use hot swap where the platform supports it (the datasheet states hot swapping fallback: Yes). Dimensions are 32 mm (W) x 103.7 mm (H) x 86 mm (D) and weight 0.115 kg. Wire sensors with shield and keep them separate from power cables.
Check each channel with a simulator switch and watch the channel LEDs. A channel that stays on may indicate a field short or a leaking sensor. Keep a spare module because input modules are among the more frequently replaced items in a busy plant.
Typical applications of the BMXDDI1602 in Oman and the GCC
The BMXDDI1602 serves valve limit switches, motor status contacts, pressure switches and push-buttons in utilities, water and wastewater, oil and gas and building plants across Oman and the GCC. Cabinet temperature and clean field wiring are the main reliability drivers.
Wiring and diagnostics tips for the BMXDDI1602
Sink inputs expect the field device to deliver the positive voltage to the channel, so PNP (sourcing) sensors and dry contacts fed from the 24 V sensor supply are the usual match. Keep sensor wiring away from motor cables, use shielded cable for long runs, and group channels by sensor supply so that a single supply fault is easy to isolate.
The module reports a channel state on its LEDs and can detect the loss of sensor supply through its voltage threshold. During commissioning, step through every channel with the real device where possible; a simulated contact does not reveal wiring faults on the field side. Record the channel assignment in the I/O list so that a replacement module can be wired exactly like the original.
Information to send with an RFQ for the BMXDDI1602
- Full reference BMXDDI1602 and quantity
- Rack and slot arrangement
- Sensor types and voltages
- Connector or cable accessories
- Delivery location and timing
Site conditions in Oman for the BMXDDI1602
Control cabinets in Gulf plants often run hot, because many sit in outdoor kiosks or in rooms where air conditioning is not always reliable. Before you finalise the BMXDDI1602, check the permitted ambient range and any derating stated by the manufacturer against the real temperature inside your panel, and leave the recommended spacing around the device so that heat can escape. Long cable runs between the field and the marshalling cabinet are common on large sites, so confirm the signal types, wiring limits and earthing arrangement early in the design.
It also helps to standardise on a small number of part numbers across a project. Keeping a few spare BMXDDI1602 units on site in Oman shortens recovery time after a fault, and documenting configuration settings makes replacement faster for the maintenance team.
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Other Models in the Se Bmx Range
Seven Star LLC supplies models from the Se Bmx range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric BMXP342020 M340 Processor Module | PLC & I/O Cards | View details |
| Schneider Electric BMXCPS2000 X80 Power Supply 100-240 V AC | Power Modules | View details |
| Schneider Electric BMXDDI1602 X80 16-Input 24 V DC Module | PLC & I/O Cards | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric BMXDDI1602 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric BMXDDI1602 X80 16-Input 24 V DC
Answers from our engineering team on installation, compatibility and integration.
01How many channels does the BMXDDI1602 have?
16 isolated discrete inputs at 24 V DC.
02Is the BMXDDI1602 sink or source?
The datasheet lists positive logic (sink).
03What is the response time of the BMXDDI1602?
Typical 4 ms, maximum 7 ms.
04Does the BMXDDI1602 support hot swap?
The datasheet lists hot swapping fallback: Yes.
05What is the current consumption of the BMXDDI1602?
76 mA DC typical.


















Reviews