Hydac EVS 3106-A-0060-000 Turbine Flow Transmitter, 15.9 gpm
Description
Hydac EVS 3106-A-0060-000 is an electronic flow rate transmitter that works on the turbine principle: an impeller spins in the oil stream and the speed is converted to a 4 to 20 mA analog signal. This part covers 1.59 to 15.9 gpm in an aluminium housing with G1/2 female threads at both ends and a male M12x1 plug. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
How EVS 3106-A-0060-000 works and where it fits
Because a turbine meter has few moving parts and no heating element, it is a common sensor for hydraulic test stands, filtration carts and lubrication skids. The 0060 range is the second step of the aluminium EVS 3100 group, between the 0.26 to 5.28 gpm and the 3.96 to 79.3 gpm units. It is calibrated at 30 cSt, so the best accuracy of 2 percent of the actual value applies to typical hydraulic oils.
Scaling is linear: 4 mA is the bottom of the range and 20 mA is 15.9 gpm. A reading of 12 mA therefore corresponds to about 8.7 gpm. Because the catalog states the minimum flow of 1.59 gpm as the start of the range, a signal near 4 mA does not necessarily mean zero flow; the impeller needs a minimum flow to turn. Use a separate flow switch if you need a reliable no-flow alarm.
Features of EVS 3106-A-0060-000
- Range 1.59 to 15.9 gpm; 2 percent of actual value.
- Maximum pressure 5800 psi.
- G1/2 female both ends; nominal bore 11 mm.
- Two extra G1/4 ports for pressure or temperature sensors.
- Viscosity range 1 to 100 cSt.
- Supply 10 to 32 V DC, two-wire.
Technical specifications of EVS 3106-A-0060-000
| Parameter | Value |
|---|---|
| Model code | EVS 3106-A-0060-000 |
| Material number (catalog) | 909810 |
| Measuring principle | Turbine, impeller speed converted to 4 to 20 mA |
| Measuring range | 1.59 to 15.9 gpm |
| Housing material | Aluminium |
| Process connection | G1/2, female on both ends |
| Nominal bore | 11 mm |
| Overall length | 144 mm (height 135 mm) |
| Tightening torque | 95 lb-ft (130 N·m) |
| Maximum operating pressure | 5800 psi |
| Extra ports | 2 x G1/4 female for pressure or temperature sensors |
| Measuring medium | Hydraulic oils |
| Viscosity range / calibration | 1 to 100 cSt / 30 cSt |
| Accuracy | 2 percent of the actual value or less |
| Output signal | 4 to 20 mA, 2-wire; load RLmax = (UB – 10 V) / 20 mA in kOhm |
| Supply voltage | 10 to 32 V DC, ripple 5 percent or less |
| Electrical connection | Male M12x1, 4-pole (mating connector not supplied) |
| Pins | 1 signal +, 3 signal -, 2 and 4 reserved |
| Protection class | IP 67 with an IP 67 connector |
| Fluid temperature | -4 to 194 degF |
| Operating / compensated temperature | -4 to 158 degF |
| Storage temperature | -40 to 212 degF |
| Weight | 1.89 lb (about 860 g) |
| EMC | CE, EN 61000-6-1/2/3/4 |
Applications
Use it to check pump delivery on a hydraulic power unit, to monitor oil flow in a gearbox lubrication line or to log consumption during a filtration job. In GCC workshops it is common on test benches for pumps and motors, where EVS 3106-A-0060-000 sends a live value to a data logger. It is meant for oils, not for water; the water-based series EVS 3110 is a different part.
How EVS 3106-A-0060-000 differs from other EVS 3106 and 3104 variants
EVS 3106-A-0020 covers 0.26 to 5.28 gpm with G1/4 ports and 60 N·m. EVS 3106-A-0300 covers 3.96 to 79.3 gpm with G1 1/4 ports and 500 N·m. The 0600 version covers 10.6 to 159 gpm at G1 1/2 and a pressure of 4567 psi. The 3104 series has the same measuring cell with a Binder 714 M18 connector instead of M12. For EVS 3106-A-0060-000 the weight is 1.89 lb and the bore 11 mm.
Selection notes
Choose the unit so that normal flow lies in the middle of the 1.59 to 15.9 gpm range. For oils far from 30 cSt the reading will shift; at very low viscosity the lower end of the range is affected. A straight run of pipe before the meter improves repeatability of EVS 3106-A-0060-000.
Installation
Fit in the flow direction shown by the arrow on the housing, thread the G1/2 ports and tighten within 130 N·m. Keep unused G1/4 ports closed with suitable pipe plugs. Connect signal plus to pin 1 and signal minus to pin 3 of the M12 plug and supply 10 to 32 V DC. Observe that the loop load must stay below (UB minus 10 V) divided by 20 mA.
Maintenance
Keep the oil clean: a particle-laden fluid wears the bearing of the impeller and shifts the reading. Compare the output with a reference meter once a year and flush the line before removing EVS 3106-A-0060-000.
Spare-part planning: the Hydac material number 909810 identifies this M12 version. The mating M12 connector is not supplied with the meter, so add it to the order when needed.
Selection Notes for the Hydac EVS 3106-A-0060-000
When comparing the Hydac EVS 3106-A-0060-000 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Hydac turbine & positive displacement flowmeters range and confirm the correct order code before you commit.
Frequently asked questions about EVS 3106-A-0060-000
What flow range does EVS 3106-A-0060-000 cover? 1.59 to 15.9 gpm (6 to 60 l/min) on a 4 to 20 mA output, with a fluid of 30 cSt as calibration viscosity.
What do the digits 3106 mean? 31 is the series, 0 means an aluminium housing, 6 means a male M12x1 4-pole connector; the 4 variant would use a Binder 714 M18 connector.
How is the pressure rated? The datasheet gives 5800 psi for the 0060 range and the catalog gives the same maximum pressure.
Can I add sensors? Yes, two G1/4 female ports in the turbine housing accept a pressure or temperature sensor.
How do I enquire? Send an RFQ with EVS 3106-A-0060-000, quantity and delivery site to Seven Star LLC.
Documents and quotation
The datasheet for EVS 3106-A-0060-000 is attached. Send an RFQ with EVS 3106-A-0060-000, quantity and delivery location to receive availability and lead time.
Datasheets & Documents
- Datasheet Hydac EVS 3106-A-0060-000 Turbine Flow Transmitter, 15.9 gpm Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac EVS 3106-A-0060-000 Turbine Flow Transmitter,
Answers from our engineering team on installation, compatibility and integration.
01What flow range does EVS 3106-A-0060-000 cover?
1.59 to 15.9 gpm (6 to 60 l/min) on a 4 to 20 mA output, with a fluid of 30 cSt as calibration viscosity.
02What do the digits 3106 mean?
31 is the series, 0 means an aluminium housing, 6 means a male M12x1 4-pole connector; the 4 variant would use a Binder 714 M18 connector.
03How is the pressure rated?
The datasheet gives 5800 psi for the 0060 range and the catalog gives the same maximum pressure.
04Can I add sensors?
Yes, two G1/4 female ports in the turbine housing accept a pressure or temperature sensor.
05How do I enquire?
Send an RFQ with EVS 3106-A-0060-000, quantity and delivery site to Seven Star LLC.