- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: KRACHT
KRACHT SVC 250 K1L1D2SH Screw Flow Meter
Description
KRACHT SVC 250 K1L1D2SH overview
KRACHT SVC 250 K1L1D2SH is a KRACHT SVC screw type flow meter: two high-precision screw spindles on rolling-element bearings are turned by the liquid itself, and every pulse corresponds to 18.2500 cm3 passing the instrument in axial direction.
Because the spindles lead the flow straight through the housing, there is no pressure or flow pulsation from the measuring principle and no settling section is needed on either side, so the device can be installed close to pumps and valves.
For this size the instrument includes 25.0 to 3 750 l/min with a pulse frequency of 3425 Hz at highest flow; an acoustic level of up to 52 dB(A) keeps it quiet in machine halls.
All moving parts are lubricated by the measured medium. The meter tolerates viscosities up to 2 500 000 mm2/s, depending on flow, with characteristic accuracy of plus or minus 0.2 percent from 20 mm2/s.
SVC 250 K1L1D2SH features
- Very low pressure drop: temporary loss up to 25 bar, permanent up to 7 bar at half of highest flow
- Housing from spheroidal cast iron EN-GJS-400-15 with heat-treated steel spindles
- Electronics: 2 sensors, standard pre-amplifier S (24 V, media -40 to 120 degrees C), Hirschmann appliance socket H
- Measuring range 25.0 to 3 750 l/min, starting from 0.90 l/min (horizontal) or 0.06 l/min (vertical)
- Maximum pressure of 40 bar in the standard version
- FKM low temperature with standard electronics: medium temperature -40 to 120 degrees C
Technical data of SVC 250 K1L1D2SH
| Parameter | SVC 250 K1L1D2SH |
|---|---|
| Pulse volume | 18.2500 cm3 per pulse |
| Manufacturer | KRACHT GmbH, Werdohl, Germany |
| Measuring spindles / bearings | heat-treated steel, ball bearing |
| Viscosity | up to 2 500 000 mm2/s depending on flow |
| Sensors / electronics | 2 sensors, standard pre-amplifier S (24 V, media -40 to 120 degrees C), Hirschmann appliance socket H |
| Measuring range | 25.0 to 3 750 l/min |
| Type code | SVC 250 K1L1D2SH |
| Pulse frequency at Qmax | 3425 Hz |
| Measuring accuracy | up to plus/minus 0.2 percent of measured quantity from 20 mm2/s; repeatability plus/minus 0.05 percent |
| Connection | DIN flange (code D) |
| Sealing | FKM low temperature (code L) |
| Starting flow | 0.90 l/min horizontal, 0.06 l/min vertical mounting |
| Resolution | 54.80 pulse/l (4-fold evaluation 219.20 pulse/l) |
SVC 250 K1L1D2SH type key by position
| Position | Code and meaning |
|---|---|
| SVC | screw type flow meter |
| 250 | nominal size 250 |
| K | ball bearing |
| 1 | standard version, spheroidal cast iron EN-GJS-400-15 housing with steel spindles |
| L | FKM low temperature sealing |
| 1 | standard coated |
| D | DIN flange |
| 2 | 2 sensors |
| S | standard pre-amplifier |
| H | Hirschmann appliance socket (standard) |
How SVC 250 K1L1D2SH differs from further SVC variants
The SVC range has five nominal sizes, 4, 10, 40, 100 and 250, with pulse volumes of 0.2550, 1.4180, 5.1300, 9.8200 and 18.2500 cm3. SVC 250 K1L1D2SH uses 18.2500 cm3.
Size 100 beside it manages 10.0 to 1 500 l/min and 140 bar, whilst SVC 250 K1L1D2SH extends over 25.0 to 3 750 l/min and 40 bar, so the measuring range shifts by a factor of about 1.9.
Size 250 has the lowest pressure rating of the range at 40 bar, the coarsest resolution of 54.80 pulse/l and the highest starting flow of 0.90 l/min horizontal (0.06 l/min vertical), which is why vertical mounting is worth considering for low flow.
Where SVC 250 K1L1D2SH is applied in Oman and the GCC
Large-diameter transfer lines in tank terminals and fuel supply to big gensets suit the 3 750 l/min range.
In process plants, flow may be reported to a PLC through the pulse output, a 4 to 20 mA analogue version or an IO-Link version, depending on the electronics letter in the code.
Transfer and loading lines that run near the 40 bar limit of the standard version can use the meter directly as the measuring principle causes only a very low pressure drop.
Fuel-oil and lube-oil consumption on engines, gensets and turbines in the Gulf can be measured with SVC 250 K1L1D2SH over 25.0 to 3 750 l/min without a straight run upstream.
Selection and compatibility notes for SVC 250 K1L1D2SH
Highest pressure 40 bar, permanent pressure loss up to 7 bar at 50 percent of maximum flow, and temporary loss up to 25 bar.
Connection DIN flange: big DIN flanges connect to DN-class pipework.
Signal chain: 2 sensors, standard pre-amplifier S (24 V, media -40 to 120 degrees C), Hirschmann appliance socket H; supply voltage and connector are fixed by the last letters of the code.
Flow window: stay within 25.0 to 3 750 l/min, since the catalogue derives resolution and pulse frequency from that range.
Installation and commissioning of SVC 250 K1L1D2SH
Wire the pre-amplifier per the datasheet pin assignment and check that the counter can follow 3425 Hz at highest flow.
Install SVC 250 K1L1D2SH with the connection DIN flange; no inlet or outlet straight lengths are needed and the unit may be mounted in any position.
Flush the line before fitting the instrument and consider a filter ahead of it, since the screw spindles are precision parts.
Maintenance of SVC 250 K1L1D2SH
Note the code SVC 250 K1L1D2SH from the type plate when asking for a replacement so that the bearing, seal and electronics letters match.
Maintenance is limited to keeping the medium clean and checking the connector and FKM low temperature sealing for leaks.
SVC 250 K1L1D2SH FAQ summary
What is the pressure rating of KRACHT SVC 250 K1L1D2SH? 40 bar, the lowest of the SVC range.
What is the flow range of SVC 250 K1L1D2SH? 25.0 to 3 750 l/min.
What does the L in SVC 250 K1L1D2SH mean? FKM low-temperature sealing, usable from -40 degrees C.
Documents and quotation
The KRACHT SVC screw type flow meter catalogue (type key, operating parameters, electronics and drawings) is supplied with this page as a PDF for SVC 250 K1L1D2SH.
To request a quotation, send an RFQ that names the exact code SVC 250 K1L1D2SH, the quantity and the delivery place in Oman or the GCC. A photo of the name plate helps us verify each code position.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Other Models in the Svc Screw Flow Meter Range
Seven Star LLC supplies models from the Svc Screw Flow Meter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT SVC 100 K1F1D2HH Screw Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT SVC 250 K1L1D2SH Screw Flow Meter | Turbine & Positive Displacement Flowmeters | You are viewing this model |
| KRACHT SVC 10 K1F1R2SH Screw Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
Datasheets & Documents
- Datasheet KRACHT SVC 250 K1L1D2SH Screw Flow Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT SVC 250 K1L1D2SH Screw Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What is the pressure rating of KRACHT SVC 250 K1L1D2SH?
40 bar, the lowest of the SVC range. This is taken from the KRACHT datasheet for SVC 250 K1L1D2SH.
02What is the flow range of SVC 250 K1L1D2SH?
25.0 to 3 750 l/min. This is taken from the KRACHT datasheet for SVC 250 K1L1D2SH.
03What does the L in SVC 250 K1L1D2SH mean?
FKM low-temperature sealing, usable from -40 degrees C.
04What is the starting flow of SVC 250 K1L1D2SH?
0.90 l/min horizontal or 0.06 l/min vertical.
05What is the resolution of SVC 250 K1L1D2SH?
54.80 pulse/l, or 219.2 pulse/l with 4-fold evaluation.


















Reviews