Hanna Instruments HI98129 pH/EC/TDS/Temperature Tester

Description

Hanna HI98129 pH, EC, TDS and temperature pocket tester: what it is

The Hanna Instruments HI98129 is a pocket-sized combination tester that reads pH, electrical conductivity (EC), total dissolved solids (TDS) and temperature from a single waterproof body. It is the low-range version of a pair: the Hanna HI98129 covers EC up to 3999 µS/cm and TDS up to 2000 ppm, while the HI98130 extends the range to 20.00 mS/cm and 10.00 ppt. Seven Star LLC supplies the Hanna HI98129 in Oman and the GCC as an independent supplier in Muscat, mainly for water-quality checks where one operator needs both acidity and salinity numbers in the same sample without carrying two instruments.

Two buttons run everything: one switches the meter on and steps through modes, the other selects pH or EC/TDS and holds the display. The case is designed to float, so a dropped tester can be recovered from a tank or sample bucket.

How the HI98129 is built: replaceable pH cartridge and graphite EC probe

The pH sensor on the HI98129 is the HI73127 electrode, a replaceable cartridge with a stainless-steel round connector and an extendable cloth junction. There are no pins to bend, and when the glass is exhausted the cartridge is changed with the HI73128 removal tool instead of discarding the tester. The conductivity cell uses graphite contacts, which the manufacturer notes are less prone to salt-deposit errors than metal electrodes, and an exposed stainless-steel temperature sensor gives fast response for temperature compensation.

HI98129 technical specifications

Parameter Specification
Manufacturer / part number Hanna Instruments / HI98129
pH range, resolution, accuracy 0.00 to 14.00 pH, 0.01 pH, ±0.05 pH at 25 °C
pH calibration Automatic, one or two points, with pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18 buffer sets
EC range, resolution, accuracy 0 to 3999 µS/cm, 1 µS/cm, ±2% of full scale
TDS range, resolution, accuracy 0 to 2000 ppm (mg/L), 1 ppm, ±2% of full scale
EC/TDS calibration Automatic, one point at 1413 µS/cm or 1382 ppm
EC-to-TDS conversion factor Adjustable from 0.45 to 1.00
Temperature compensation Automatic for pH, EC and TDS; EC/TDS coefficient adjustable from 0.0 to 2.4 %/°C
Temperature display 0.1 °C or 0.1 °F resolution, ±0.5 °C accuracy
pH electrode HI73127 replaceable cartridge, included
Power 4 x 1.5 V batteries, automatic shut-off after 8 minutes without use
Operating environment 0 to 50 °C, up to 100% relative humidity

Measuring with the HI98129: calibration and compensation

Before first use the pH side is calibrated with the buffer sachets supplied: a one-point calibration in pH 7.01 corrects offset, and adding pH 4.01 or 10.01 sets the slope. The meter recognises the buffer value automatically and shows a stability tag until the reading settles. The EC and TDS side needs only one point; the tester accepts 1413 µS/cm for EC or 1382 ppm for TDS and applies the temperature coefficient chosen in set-up. Because the TDS display is calculated from conductivity, the conversion factor should be set to match the salt composition of the sample (0.50 is typical for NaCl-type water, 0.70 for hardness-dominated water), and the result should be described as an estimate rather than a gravimetric value.

Setup mode lets the user choose °C or °F and select either the standard or the NIST buffer set. A hold function freezes a reading for note-taking, and the battery indicator and automatic shut-off protect against unreliable readings on weak cells.

Choosing between the HI98129 and related Hanna testers

The HI98129 fits when sample conductivity stays below about 4 mS/cm, such as drinking water, boiler feed, cooling-water makeup, hydroponic nutrient solutions and treated effluent. For brackish, process or seawater duty the HI98130 with its 20.00 mS/cm range is the better match. If ORP is required instead of conductivity, the HI98121 pH/ORP/temperature tester uses the same housing and cartridge. Larger waterproof meters with a separate probe and data logging, such as the HI98199 or HI991300, suit users who need to record results.

Selection and ordering checklist for the HI98129

  • Expected conductivity: confirm it stays within 0 to 3999 µS/cm, otherwise consider the HI98130.
  • pH buffer set preferred (standard or NIST) so that the supplied sachets match your procedure.
  • Spare consumables: replacement HI73127 pH cartridges, extra buffer, conductivity standard and electrode storage solution.
  • Whether results must be logged; the tester has no data memory, so a meter with logging is needed for audit trails.
  • Quantity, so that one tester can be assigned per team or per shift.

Care, storage and replacement parts for the HI98129

Rinse the probe with clean water after each use and keep the pH cartridge moist with storage solution. Do not store the tester dry or in distilled water, which shortens electrode life. If the pH slope falls or response becomes slow, soak the cartridge in cleaning solution and recalibrate; if that does not help, swap the HI73127 with the HI73128 tool. The graphite EC contacts can be wiped clean of oily films. Recalibrate at least monthly, whenever the cartridge is changed and after measuring aggressive samples, as the instruction manual recommends.

HI98129 applications in Oman and the GCC

Typical local uses include spot checks on potable-water tanks and tankers, reverse-osmosis permeate and feed, cooling-tower makeup and blowdown, swimming-pool and hotel water systems, agriculture and greenhouse irrigation, and wastewater plants. High ambient temperatures change both conductivity and pH, so automatic compensation is important; the manufacturer specifies operation up to 50 °C, so samples taken in direct sun should be shaded and the tester kept out of hot vehicles.

HI98129 and HI98130 side by side

Item HI98129 HI98130
EC range 0 to 3999 µS/cm 0.00 to 20.00 mS/cm
TDS range 0 to 2000 ppm 0.00 to 10.00 ppt
EC calibration standard 1413 µS/cm or 1382 ppm 12880 µS/cm or 6.44 ppt
Typical sample Drinking water, RO permeate, nutrient solution Brackish water, process water, seawater

Information to send with your HI98129 RFQ

  • Quantity and any spare pH cartridges or solutions.
  • Sample type and expected conductivity and pH.
  • Preferred buffer set and temperature unit.
  • Delivery location in Oman or the GCC.

Documents and quotation

The HI98129 and HI98130 instruction manual is attached on this page for reference, with the full specification, calibration steps and accessory list.

Send us the part number HI98129 and your quantity and Seven Star LLC will confirm availability and lead time for Oman and the GCC. We act as an independent supplier and are not affiliated with the manufacturer.

Datasheets & Documents
  • PDF Manual Hanna Instruments HI98129 Instruction Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.

Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.

Hanna Instruments company profile

Founded 1978, near Padua, Italy, by Oscar and Anna Nardo
Headquarters Woonsocket, Rhode Island, USA
Leadership Martino Nardo and Pamela Nardo
Early product The pHep pocket pH tester
Product families pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers

Hanna product series

Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.

The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.

Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.

Where Hanna instruments are used

Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.

Hanna Instruments products we list

Family Examples
Portable Test & Measurement Hanna HI97711 Free and Total Chlorine Po…, Hanna HI98190 Waterproof Portable pH and…, Hanna HI98192 Waterproof Portable EC, Hanna HI98193 Waterproof Portable Dissol…, Hanna HI98199 Portable pH, Hanna HI9829 Multiparameter Water Qualit…, Hanna HI98703 Portable Turbidity Meter

Ordering Hanna instruments: what we need

Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.

Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.

FAQ

Questions about the Hanna Instruments HI98129 pH/EC/TDS/Temperature

Answers from our engineering team on installation, compatibility and integration.

01What is the difference between the HI98129 and the HI98130?
Both measure pH, EC, TDS and temperature in the same housing. The HI98129 covers EC 0 to 3999 µS/cm and TDS 0 to 2000 ppm, whereas the HI98130 covers 0.00 to 20.00 mS/cm and 0.00 to 10.00 ppt for saltier samples.
02Can the pH cartridge of the HI98129 be replaced?
Yes. The pH sensor is the HI73127 replaceable cartridge with a snap-in connector, and the HI73128 removal tool supplied with the tester is used to remove it, so the whole tester does not have to be replaced.
03How is the HI98129 calibrated for EC and TDS?
EC and TDS use automatic one-point calibration, with 1413 µS/cm for EC or 1382 ppm for TDS. The conversion factor from 0.45 to 1.00 and the temperature coefficient are set by the user.
04Does the HI98129 compensate for temperature?
Yes. pH, EC and TDS readings are automatically temperature compensated. The EC/TDS coefficient is adjustable from 0.0 to 2.4 %/°C and temperature is displayed in °C or °F.
05Is the HI98129 suitable for seawater or high-salinity brine?
No, its EC range ends at 3999 µS/cm. For brackish or seawater samples the HI98130 or a larger conductivity meter with a wider range should be selected.