Brand: Hanna Instruments
Hanna Instruments HI1131B Refillable Combination pH Electrode
Description
Hanna HI1131B Refillable Combination pH Electrode overview
Hanna Instruments HI1131B is the part number of the Refillable Combination pH Electrode. This page summarises what the maker publishes for HI1131B, so that maintenance teams, laboratory managers and procurement staff in Oman and the GCC can check the key parameters before sending a request for quotation. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Every figure below comes from the published product information and should be confirmed against the current documentation for your instrument and application.
A pH electrode converts the hydrogen ion activity of a sample into a small voltage that a meter, controller or transmitter turns into a pH reading. The glass membrane, the reference system and the junction all influence how fast, stable and repeatable that reading is, which is why the exact model matters when an installed instrument is repaired. Probes and electrodes are consumables: they age with use, so buyers often search for the exact order code such as HI1131B to replace a unit on an installed meter without changing the measuring method that was validated on site.
Key features of HI1131B
- Described by the maker as: refillable, combination pH electrode.
- Body material: glass.
- Connection: BNC.
- Measuring range: pH: 0 to 13.
- Operating temperature: 0 to 100°C (32 to 212°F).
- Electrolyte: 3.5M KCl.
- Maximum pressure: 0.1 bar.
- Cable: coaxial 1 m (3.3′).
- Recommended use: laboratory general purpose, beer.
Technical specifications of HI1131B
The table lists the values printed by the manufacturer for HI1131B. Entries that the maker does not publish have been left out instead of estimated.
| Parameter | Value |
|---|---|
| Part number | Hanna HI1131B |
| Description | refillable, combination pH electrode |
| Reference | double, Ag/AgCl |
| Electrolyte | 3.5M KCl |
| Maximum pressure | 0.1 bar |
| Measuring range | pH: 0 to 13 |
| Operating temperature | 0 to 100°C (32 to 212°F) |
| Tip shape | spheric (dia: 9.5 mm) |
| Temperature sensor | DIN model only |
| Built-in amplifier | DIN model only |
| Body material | glass |
| Cable | coaxial 1 m (3.3′) |
| Connection | BNC |
| Recommended use | laboratory general purpose, beer |
Reading the HI1131B data
For a pH electrode the operating temperature and the pressure limit define where the sensor can be installed, and the junction type decides how well it copes with dirty, viscous or low conductivity samples. Hanna HI1131B is stated for 0 to 100°C (32 to 212°F) and for laboratory general purpose, beer. Check these against the process before choosing between similar-looking models in the same family.
Typical applications of HI1131B in Oman and the GCC
Water quality and process chemistry measurements are routine in the region. In oil and gas facilities the water laboratory checks boiler feed, produced water treatment, cooling water and effluent. Utilities and desalination plants monitor raw water, product water and chemical dosing steps. Municipal wastewater works, food and beverage plants and general manufacturing use similar sensors for quality control. The maker lists the following recommended use for HI1131B: laboratory general purpose, beer. Hot ambient conditions make careful storage and regular calibration particularly important, because dry or overheated sensing elements age quickly.
Selection and compatibility notes for HI1131B
Before ordering HI1131B, confirm three points. First, the connector: the table shows BNC, and it must match the meter input, because BNC, DIN, quick connect DIN, banana and 3.5 mm styles are not interchangeable. Second, the sample: compare the temperature and pressure limits and the body material with your process. Third, the measuring task: models in the same family differ in tip shape, junction, electrolyte and amplifier, so a similar looking code can behave differently. If you are replacing an existing electrode, quote the code printed on the old one together with the meter model, and mention if an alternative is acceptable.
Installation and commissioning of HI1131B
Remove the protective cap or soaking bottle if one is fitted, rinse the sensor with clean water and connect it to the instrument before switching it on. Refillable models should be topped up with the electrolyte stated in the table and the fill hole opened during measurement. Calibrate with fresh standards that bracket the expected values, using the procedure of the meter in use, and note the slope or offset after commissioning. For HI1131B keep the cable away from power cables and motors, and do not bend the coaxial or multi-pole cable sharply, since cable damage is a frequent source of unstable readings.
Maintenance and storage for HI1131B
Keep sensing elements wet in the storage or soaking solution recommended by the maker, clean them with a suitable cleaning solution when the response slows, and replace the sensor when calibration can no longer be achieved. Rinse between samples and avoid touching glass or metal surfaces. Record the date of installation and the calibration results so the working life of HI1131B in your application is known, and keep one spare of the exact code in a cool, clean store for planned outages.
Good measurement practice for sensors of this type
Reliable results depend as much on routine as on hardware. Use fresh calibration standards, store opened bottles tightly closed, and discard standards that have been contaminated by dipping a wet sensor. Allow the reading to stabilise before accepting a value, because a drifting display usually means the sensor has not reached equilibrium with the sample or the temperature. Record the sample temperature, since most chemical measurements change with it. In hot climates samples left in a vehicle can warm quickly, so measure on site wherever possible and keep sensors out of direct sun. When a sensor shows a slow response, a low slope, a large offset or noisy readings, clean it, recalibrate, and only then consider replacement. Keep a simple log for each measuring point that lists the sensor code, installation date, cleaning dates and calibration results. Such a log makes it easy to see whether a failure is caused by the sample, by handling or by ordinary ageing, and it supports audits in laboratories that follow quality systems. Training operators to rinse, blot and store sensors correctly is usually the cheapest way to extend sensor life and to reduce repeat purchases.
Related products and ordering notes for HI1131B
Hanna Instruments offers many electrodes that differ only by connector, body material or junction, so the part number is the only reliable identifier. Alongside HI1131B we can quote related buffers, storage and cleaning solutions, reference electrodes and meters when you are reviewing a whole measuring point. Availability and lead time are confirmed per request, and no price is shown on this page.
Frequently asked points about HI1131B
- What is HI1131B? It is the part number of the Refillable Combination pH Electrode.
- Which connector does it use? BNC.
- What is the stated temperature range? 0 to 100°C (32 to 212°F).
- How do I order? Send the RFQ with the part number HI1131B and the required quantity.
Documents and quotation
The official Hanna Instruments HI2210 / HI2211 pH/mV/°C Bench Meter Instruction Manual is attached to this page as a PDF. Page 3 of the manual lists HI1131B as the glass-body pH electrode with BNC connector and 1 m cable supplied with every HI2210 and HI2211 bench meter, and the accessories chapter (page 15) describes it as a double junction, refillable combination electrode for general purpose use. Include HI1131B, the quantity and the instrument it will be used with in your inquiry and we will reply with availability and a written quotation.
Datasheets & Documents
- Datasheet Hanna HI2210 / HI2211 pH Bench Meter Instruction Manual (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.
Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.
Hanna Instruments company profile
| Founded | 1978, near Padua, Italy, by Oscar and Anna Nardo |
|---|---|
| Headquarters | Woonsocket, Rhode Island, USA |
| Leadership | Martino Nardo and Pamela Nardo |
| Early product | The pHep pocket pH tester |
| Product families | pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers |
Hanna product series
Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.
The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.
Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.
Where Hanna instruments are used
Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.
Hanna Instruments products we list
Ordering Hanna instruments: what we need
Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.
Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.
Browse Hanna Instruments products by category: Portable Test & Measurement.
FAQ
Questions about the Hanna Instruments HI1131B Refillable Combination pH
Answers from our engineering team on installation, compatibility and integration.
01What is Hanna Instruments HI1131B?
HI1131B is the part number of the Refillable Combination pH Electrode, as listed by the manufacturer.
02What connector does HI1131B use?
The manufacturer lists the connection as BNC.
03What temperature range is stated for HI1131B?
The manufacturer states 0 to 100°C (32 to 212°F) for this item.
04What is HI1131B recommended for?
The maker lists the following use: laboratory general purpose, beer.
05How do I request a quote for HI1131B?
Send an RFQ to Seven Star LLC with the part number HI1131B and quantity. We are an independent supplier and not affiliated with the manufacturer.