- Automation & ControlView all 2,901 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser TM311 iTHERM CompactLine Thermometer
Description
What the Endress+Hauser TM311 is built for
Endress+Hauser TM311 belongs to the iTHERM CompactLine group: a one-piece stainless steel thermometer with an M12 connector rather than a terminal head. The Technical Information TI01439T describes it as a metric and imperial compact RTD thermometer with 4 to 20 mA or IO-Link output, aimed at hygienic and aseptic work in food, beverage and pharmaceutical plants and at machine and skid builders who want one standardised sensor. Its measuring element is a Pt100 of Class A in four-wire connection, the housing is IP69 and the process pressure limit is 50 bar. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Measuring performance of TM311
Two sensor grades are offered. A basic thin-film Pt100 measures -50 to +150 degrees C, while the iTHERM TipSens version extends to -50 to +200 degrees C and is the fast one. Response is where the two grades differ most. In water at 0.4 m/s, per IEC 60751, the basic sensor in a 6 mm straight tip needs 5 s for t63 and under 20 s for t90, while TipSens in the same tip needs 1 s and 1.5 s. In a 6 mm thermowell with reduced 4.3 x 20 mm tip, TipSens reaches t90 in 3 s without paste and 2.5 s with heat-transfer paste. The built-in electronics add at most 1 s.
Output signal codes
The output is selected through order code 020. Option A gives the bare Pt100 four-wire Class A element. Option B gives a variable 4 to 20 mA range with a C/Q digital line that works as IO-Link or switch output. Option C fixes the analogue span at 0 to 150 degrees C and keeps the C/Q line. Electronics versions detect on their own whether the cable is wired for IO-Link or for 4 to 20 mA.
| Device family | iTHERM CompactLine, compact thermometer |
|---|---|
| Sensor | Pt100 thin film, Class A, 4-wire |
| Range, basic sensor | -50 to +150 degrees C |
| Range, TipSens | -50 to +200 degrees C |
| Outputs | Pt100, or 4 to 20 mA plus IO-Link / switch (C/Q) |
| Supply voltage | 10 to 30 VDC, reverse-polarity protected; at least 15 V for IO-Link |
| Switch output | 1 x PNP, up to 200 mA, drop up to 2 V, over 10 000 000 cycles |
| Switch response time | Up to 100 ms |
| Fault signalling | NAMUR NE43 in 4 to 20 mA mode |
| Ambient / storage | -40 to +85 degrees C |
| Altitude | Up to 2 000 m |
| Protection | IP69 |
| Vibration | 3 g, 10 to 500 Hz |
| Weight | 0.2 to 2.5 kg, standard versions |
| Wetted material | 316L (1.4435), delta ferrite under 1 percent or 0.5 percent |
| Surface | Ra up to 0.76 um standard; Ra up to 0.38 um polished or electropolished |
| Pressure | Up to 50 bar (725 psi) |
Electrical behaviour worth planning for
The TM311 must be fed from a type-examined transmitter power supply, and marine installations need extra overvoltage protection according to the datasheet. When the PNP switch output carries more than 220 mA in the ON state the device drops to a safe state and reports an overload; the output opens when a fault is active. No pull-down resistor exists inside the device. For 4 to 20 mA operation, underrange falls linearly from 4.0 to 3.8 mA under NE43. Configuration for IO-Link uses a tool such as the FieldPort SFP20 USB interface, or the PLC master.
How TM311 differs from other compact and ModuLine thermometers
Unlike the TM101 or TM111 with terminal heads, the TM311 has no exchangeable insert and no head transmitter slot; electronics are integrated. Its sensor is a Class A four-wire Pt100 with optional TipSens response in the 1 s class, and IO-Link comes from the integrated electronics. If you need an exchangeable sensor, a thermowell is the better route.
Process connections and thermowell choices for TM311
Direct-contact and thermowell versions both use a 6 mm (1/4 in) tip. Hygienic connection sizes listed include DN25, DN38 and DN51, plus weld-in adapters in 316L (1.4435): G 3/4 in versions for pipe mounting (d = 29 mm) and vessel mounting (d = 50 mm), flanged versions, and a G 1 in adjustable adapter. The weld-in adapters are rated 25 bar up to 150 degrees C and 40 bar up to 100 degrees C. A 316L compression fitting with a spherical sealing taper is rated 50 bar and 200 degrees C at 40 Nm, but it can be used once only, because it deforms. PEEK fittings must never be used below the temperature at which they were tightened.
Installation and cleaning notes for TM311
Keep the electronics section below 85 degrees C by insulating or by choosing a longer neck when the process is hotter. The IP69 rating depends on the connection cable and plug in use. The datasheet lists resistance of the housing to several Ecolab cleaning and disinfection agents, and states conformity of process-contact parts with the European food-contact regulations, so cleaning-in-place cycles are normally acceptable. Mount in line with the surface-finish requirement, since a polished version is not compliant with ASME BPE if it has been buffed, as the footnote explains.
Applications for TM311 in Oman and GCC industry
Typical uses are dairy and juice plants, bottling and water-treatment lines, CIP return lines, pharmaceutical utilities and compact packaged skids, as well as process-water loops and heat exchangers in industrial plants where a clamp connection is already standard. With IO-Link, a single M12 cable replaces a transmitter, a head and a signal converter, which cuts installation time on modular skids.
Maintenance
There are no parts to replace inside a TM311. Maintenance consists of visual inspection of the M12 plug and cable, checking the seal of the process connection, periodic comparison with a reference sensor and recalibration or swap if drift is found. Read the diagnostic messages by IO-Link, since the device shows the three highest-priority ones.
Documents and quotation
The Technical Information for the TM311 is attached as a datasheet. Send your RFQ to Seven Star LLC with the part number TM311, your full order code, the quantity and the delivery location, and we will answer with availability.
Datasheets & Documents
- Datasheet Endress+Hauser TM311 iTHERM CompactLine Thermometer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser TM311 iTHERM CompactLine Thermometer
Answers from our engineering team on installation, compatibility and integration.
01How fast is the Endress+Hauser TM311 with TipSens?
With the iTHERM TipSens element in a 6 mm straight direct-contact tip the datasheet gives t63 of 1 s and t90 of 1.5 s, measured in water at 0.4 m/s.
02What supply voltage does the TM311 need for IO-Link?
The electronics accept 10 to 30 VDC, but IO-Link communication is only guaranteed with at least 15 V; below that the device flags a diagnostic and disables the switch output.
03Does the TM311 have a switch output?
Yes, the C/Q line can act as a PNP switch up to 200 mA with a voltage drop up to 2 V, hysteresis or window function, and normally open or closed contact.
04What is the temperature limit for the TM311 electronics?
Ambient and storage temperature are -40 to +85 degrees C, so electronics must be protected from hotter process heat conduction.
05Can the TM311 be used in CIP lines?
Its housing is IP69 and the datasheet lists resistance to Ecolab cleaning agents, with 316L (1.4435) wetted parts and polished surface options.