- Automation & ControlView all 2,736 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser FMR60 80 GHz Radar Level Transmitter, PTFE Antenna
Description
Endress+Hauser FMR60 Micropilot Endress+Hauser FMR60 overview
The Endress+Hauser Micropilot Endress+Hauser FMR60 is a free space radar transmitter for continuous, non-contact level measurement of liquids, pastes and sludges. It uses a PTFE drip-off antenna that sheds condensate and product, and it operates at approximately 80 GHz, which gives a small beam angle and good focusing.
The narrow beam makes the FMR60 useful in vessels with many internal fittings such as agitators, ladders and heating coils, because less of the signal is reflected from the obstacles. The datasheet gives a maximum measuring range of 50 m and an accuracy of plus or minus 1 mm, and up to eight devices can be installed in one tank without mutual influence.
Seven Star LLC lists the FMR60 for buyers in Oman and the GCC who need the exact model that is already installed or specified. Engineers often search by the model code, and the FMR60 is one of the products that plants reorder for replacement, expansion and maintenance work.
Key features of the FMR60
- PTFE drip-off antenna for reduced build-up and reliable measurement
- Operating frequency of approximately 80 GHz with improved focusing and a small beam angle
- Maximum measuring range of 50 m (164 ft) and accuracy of plus or minus 1 mm
- Process temperature minus 40 to plus 130 degrees C and process pressure minus 1 to plus 16 bar
- SIL2 as per IEC 61508, with SIL3 for homogeneous or diverse redundancy
- Bluetooth wireless technology with the SmartBlue app, RFID TAG and HistoROM memory
- Multi-echo tracking, Heartbeat Technology and easy proof testing for SIL and WHG
FMR60 technical specifications
| Parameter | Value |
|---|---|
| Measuring principle | Free space radar, approximately 80 GHz |
| Application | Liquids, pastes and sludges |
| Antenna | PTFE drip-off antenna |
| Maximum measuring range | 50 m (164 ft) |
| Accuracy | Plus or minus 1 mm (0.04 in) |
| Process temperature | Minus 40 to plus 130 degrees C (minus 40 to plus 266 degrees F) |
| Process pressure | Minus 1 to plus 16 bar (minus 14.5 to plus 232 psi) |
| Transmission power | Peak power 6.3 mW |
| Output | 4 to 20 mA with HART, optional switch output on HART devices |
| Functional safety | SIL2 per IEC 61508, SIL3 with redundancy |
| Operation | Local display, Bluetooth with SmartBlue, optional remote display FHX50 |
The values above are taken from the manufacturer Technical Information for the FMR60. Exact limits depend on the selected version, material, process connection and approval, so confirm the order code against the datasheet before purchase.
Typical applications of the FMR60 in Oman and the GCC
The FMR60 is used for storage tanks, process vessels with internals, reactors and buffer tanks where accurate level is needed. In Oman and the GCC it is a typical choice for refinery and petrochemical process tanks, fuel and chemical storage, and water and utility tanks that need millimetre-level accuracy.
Across oil and gas, utilities, water and wastewater, and manufacturing plants in the region, the FMR60 is selected where the application matches the limits listed in the specifications table. Hot ambient conditions, dust and long cable runs are normal in the Gulf, so check the ambient temperature range and the housing protection against the site conditions.
Selection and compatibility notes for the FMR60
Choose the FMR60 when a moderate pressure rating up to 16 bar, a high accuracy of 1 mm and a narrow beam are required. If the application involves much higher pressure or temperature, or interface measurement, other radar devices of the same manufacturer are more suitable. Check the process connection, the housing material, the output and the hazardous-area approval in the ordering structure.
Installation and commissioning of the FMR60
Install the FMR60 with the antenna axis perpendicular to the product surface and away from the filling stream. The small beam angle tolerates internal fittings better than lower-frequency radar, but a clear line of sight to the surface is still the best installation. Use the guided commissioning menu or SmartBlue, record an empty tank reference and confirm the measured distance against a manual check.
Always follow the Operating Instructions of the FMR60 and the local rules for electrical installation, especially in hazardous areas. Document the tag, configuration and as-found values at commissioning so that later service checks can be compared with them.
Maintenance of the FMR60
A scheduled inspection of the FMR60 should cover the wetted parts or sensing element for damage or build-up, the cable glands and seals for tightness, the housing cover and gasket, and the loop signal against a reference. Keep a record of the device serial number and order code, because they identify the exact version when you need a spare or replacement.
Related products and ordering notes for the FMR60
The FMR60 belongs to the Micropilot product line of the manufacturer. Neighbouring models in the same Technical Information share much of the documentation and accessories, so confirm which model the project needs. Accessories such as weather covers, mounting hardware and remote displays are specified by their own order codes.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model codes are used only to identify the item that the buyer wants to purchase.
When you prepare a purchase request for the FMR60, collect the full order code from the existing nameplate if you are replacing a unit, the tag number, the measuring range or probe length, the process connection, the electrical output and the hazardous-area certificate. Matching these details avoids mistakes with look-alike versions, and it lets the supplier confirm availability and lead time without delay. For spare or legacy requirements, the serial number printed on the nameplate helps identify the exact build.
FMR60 frequently asked questions in brief
What frequency does the FMR60 operate at? The datasheet states an operating frequency of approximately 80 GHz, which gives improved focusing and a small beam angle. What is the measuring range and accuracy of the FMR60? The maximum measuring range is 50 m (164 ft) and the accuracy is plus or minus 1 mm (0.04 in) according to the manufacturer Technical Information. What pressure and temperature can the FMR60 handle? The process temperature range is minus 40 to plus 130 degrees C and the process pressure range is minus 1 to plus 16 bar.
Documents and quotation
The manufacturer Technical Information for the FMR60 is available as a datasheet that you can download from this product page, and it lists the full ordering structure. To receive a quotation, send an RFQ with the part number FMR60, the quantity, the required version and options, and the delivery location. We reply with availability and lead time for your Oman or GCC project.
Other Models in the Eh Micropilot Range
Seven Star LLC supplies models from the Eh Micropilot range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser FMR50 Free Space Radar Level Transmitter, 26 GHz | Radar & Guided Wave Radar Level | View details |
| Endress+Hauser FMR60 80 GHz Radar Level Transmitter, PTFE Antenna | Radar & Guided Wave Radar Level | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser FMR60 80 GHz Radar Level Transmitter, PTFE Antenna Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser FMR60 80 GHz Radar Level
Answers from our engineering team on installation, compatibility and integration.
01What frequency does the FMR60 operate at?
The datasheet states an operating frequency of approximately 80 GHz, which gives improved focusing and a small beam angle.
02What is the measuring range and accuracy of the FMR60?
The maximum measuring range is 50 m (164 ft) and the accuracy is plus or minus 1 mm (0.04 in) according to the manufacturer Technical Information.
03What pressure and temperature can the FMR60 handle?
The process temperature range is minus 40 to plus 130 degrees C and the process pressure range is minus 1 to plus 16 bar.
04Is the FMR60 suitable for SIL applications?
Yes, it is listed as SIL2 per IEC 61508 and SIL3 with homogeneous or diverse redundancy, with an easy proof test.
05How do I order the FMR60 from Seven Star LLC?
Send an RFQ with the part number FMR60, the quantity, the process connection, the output and housing, and approvals. We reply with availability and a quotation.