Brand:

ABB PSTX570-600-70 PSTX Softstarter 570 A

Description

ABB PSTX570-600-70 softstarter overview

The ABB PSTX570-600-70 is a PSTX softstarter for three-phase induction motors, selected by buyers who need a controlled start and stop of pumps, fans, conveyors and compressors without the current surge of a direct-on-line start. The designation tells the story: PSTX is the range, 570 is the rated current in amperes, 600 is the maximum operating voltage class and 70 is the control-supply version. The PSTX570-600-70 operates on 208 to 600 V and takes a 100 to 250 V ac control supply at 50 or 60 Hz.

Because the PSTX570-600-70 contains a thyristor stage and a bypass, the motor is ramped up by the thyristors and the bypass takes over at full speed. That keeps heat inside the cabinet low and saves energy. This page repeats the key facts taken from the manufacturer catalog so that engineers, maintenance planners and buyers in Oman and the GCC can confirm that the PSTX570-600-70 matches the motor before sending an enquiry.

Key features of the ABB PSTX570-600-70

  • Soft start and soft stop by voltage ramp or by torque control; the catalog describes torque control as the best way to start pumps and to limit water hammer on stopping
  • Built-in bypass contactor and fan cooling that is thermostat controlled
  • Detachable graphical display with start, stop, info and remote or local keys, protected to IP66 so it can be placed on a panel door
  • Three programmable signal relays and three programmable digital inputs, plus a start and a stop input
  • Analog output with a choice of 0 to 10 V, 0 to 10 mA, 0 to 20 mA or 4 to 20 mA for current, power or temperature signals
  • Built-in Modbus RTU on an RS485 interface, with a connection for optional Anybus communication modules
  • Pre-start functions such as motor heating, stand-still brake and jog, and a pump cleaning function that can reverse flow
  • Limp mode, which keeps two-phase motor control running if one set of thyristors is shorted, so the process can continue until planned maintenance

PSTX570-600-70 technical specifications

Parameter Value
Type designation PSTX570-600-70
Series ABB PSTX softstarter
Rated operational current Ie 570 A
Current setting range 171.0 to 570.0 A
Rated operational voltage Ue 208 to 600 V, +10 percent / minus 15 percent, 50/60 Hz plus or minus 10 percent
Rated insulation voltage Ui 690 V
Rated control supply voltage Us 100 to 250 V, +10 percent / minus 15 percent, 50/60 Hz
Rated control circuit voltage Uc internal or external 24 V dc
UL/CSA FLA (ordering table) 590 A
UL/CSA power at 200/208 V 200 hp
UL/CSA power at 220/240 V 200 hp
UL/CSA power at 440/480 V 500 hp
UL/CSA power at 550/600 V 600 hp
Starting capacity 4 x Ie for 10 seconds
Starts per hour 6 (normal start, class 10, 50 percent on time)
Overload protection electronic, user-defined class 10A, 10, 20 or 30
Maximum power loss at rated Ie 146 W
Maximum fuse, main circuit (Bussmann semiconductor) 1000 A, type 170M6814, size 3
Supply circuit holding / pull-in 67/434 VA
Ambient temperature, operation minus 25 to plus 60 C, derate 0.8 percent per C above 40 C
Ambient temperature, storage minus 40 to plus 70 C
Maximum altitude 4000 m, with current derating above 1000 m
Degree of protection, supply and control circuit IP20
Detachable keypad protection IP66 (Type 1, 4X, 12)
Signal relays 3 programmable, rated 250 V ac / 24 V dc, Ith 5 A, AC-15 1.5 A
Fieldbus built-in Modbus RTU (RS485), optional Anybus
Package weight 25.00 kg

The catalog states that the integrated bypass of this size uses an AF370 contactor, rated 370 A in AC-3 at 400 V (200 kW, 300 hp at 480 V). Values are taken from the ordering and technical data tables of the manufacturer PSTX catalog; always confirm the selection against the current documentation for your voltage, duty and ambient conditions.

Typical applications of the PSTX570-600-70 in Oman and the GCC

The catalog lists centrifugal pumps, short conveyor belts, centrifugal blowers and belt presses as typical normal-duty applications for the ratings shown above, and wastewater pumps, long conveyors, mixers and positive displacement machines for heavy-duty starts, which need a larger frame or a higher class setting. In Gulf plants the PSTX570-600-70 is commonly considered for the following duties.

  • Oil and gas: water injection, cooling-water and firewater pumps, where the emergency mode keeps the starter running regardless of a trip
  • Utilities and power: boiler feed, cooling tower fans and auxiliary blowers
  • Water and desalination: booster, transfer and sewage pumps that benefit from torque control and pump cleaning
  • Manufacturing and petrochemical: conveyors, mixers, crushers and compressors that need a limited starting current on weak networks

High ambient temperatures are normal in the region, so note the derating rule: above 40 C the rated current falls by 0.8 percent per degree up to 60 C. A PSTX570-600-70 installed in a hot switchroom may need to be sized one step up.

Selection and compatibility notes for the PSTX570-600-70

Start from the motor nameplate current, not the kilowatt rating. The PSTX570-600-70 covers a setting range of 171.0 to 570.0 A, so the motor full-load current should fall inside that window. The ordering table gives 500 hp at 440 to 480 V and 600 hp at 550 to 600 V for normal-duty starts. If the application has long ramp times, frequent starts or high inertia, step up to a larger frame or choose the heavy-duty row of the catalog.

The catalog also shows a 690 V version of the range; this page covers the 208 to 600 V type PSTX570-600-70 only, so confirm the voltage suffix when ordering. For short-circuit protection the catalog recommends semiconductor fuses of type 170M6814 (size 3, up to 1000 A) for the main circuit, while a line contactor is optional and is often added to open the circuit if the overload protection trips. The control supply circuit needs a 6 A delayed device.

Installation and commissioning of the PSTX570-600-70

Mount the PSTX570-600-70 vertically on a flat panel, keeping the minimum distances to the wall given in the catalog mounting table so that the fan can move air through the heat sink. Connect the three-phase supply to the upper terminals and the motor to the lower terminals, connect the 100 to 250 V control supply, and wire start and stop to the dedicated inputs. The catalog notes that the detachable keypad can be placed on the panel door.

During commissioning enter the motor rated current, choose voltage ramp or torque control, set the current limit and the overload class, and test the ramp with the motor uncoupled where possible. The three signal relays default to run, top of ramp (bypass) and event group 0 (faults) on the PSTX570-600-70, which suits most control schemes. Record the settings so a replacement PSTX570-600-70 can be configured the same way.

Maintenance and spare parts

The PSTX570-600-70 has few wearing parts. Check that the fan runs and the heat sink is clean, tighten power terminals to the torque shown on the unit, and review the event log, which stores trips, parameter changes and operation. The device also reports thyristor runtime, a faulty fan warning and a thyristor overload warning, so planned replacement is easy to schedule. Accessories listed in the catalog include terminal lug kits, terminal extensions, Modbus and Anybus communication modules and a PSTX USB cable.

Related products and ordering notes for the PSTX570-600-70

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Neighbouring sizes of the same range, such as the PSTX470-600-70 and PSTX720-600-70, can be quoted on request. When ordering, quote the full type PSTX570-600-70 and state whether you need the 600 V or the 690 V version, the control supply and any accessories such as a Modbus or Anybus module.

PSTX570-600-70 FAQ summary

Questions about the PSTX570-600-70 usually concern the current range, the control supply, the bypass and the protections. In short, the PSTX570-600-70 is rated 570 A, uses 100 to 250 V ac control supply, has a built-in bypass and electronic overload protection, and communicates by Modbus RTU as standard.

Documents and quotation

The PSTX softstarter catalog covering the PSTX570-600-70 is attached to this page as a datasheet. To request a quotation, send an RFQ with the part number PSTX570-600-70, the quantity and your delivery location in Oman or the GCC, and we will reply with availability and lead time.

ABB PSTX570-600-70 vs Other ABB PSTX Softstarter A Variants

The ABB PSTX570-600-70 is the choice when your application specifically needs PSTX570-600-70 570. Ordering a neighbouring size or rating in this family is the most common cause of returns, so compare the figure on the existing unit or the design data sheet before you send an RFQ.

Variant Distinguishing detail
ABB PSTX470-600-70 PSTX Softstarter 470 A PSTX470-600-70 470
ABB PSTX570-600-70 PSTX Softstarter 570 A (this page) PSTX570-600-70 570
ABB PSTX720-600-70 PSTX Softstarter 720 A PSTX720-600-70 720
ABB PSTX840-600-70 PSTX Softstarter 840 A PSTX840-600-70 840

Other Models in the PSTX Range

Seven Star LLC supplies models from the PSTX range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ABB PSTX37-600-70 PSTX Softstarter 37 ASwitchgear, Enclosures & DistributionView details
ABB PSTX45-600-70 PSTX Softstarter 45 ASwitchgear, Enclosures & DistributionView details
ABB PSTX60-600-70 PSTX Softstarter 60 ASwitchgear, Enclosures & DistributionView details
ABB PSTX85-600-70 PSTX Softstarter 85 ASwitchgear, Enclosures & DistributionView details
ABB PSTX105-600-70 PSTX Softstarter 105 ASwitchgear, Enclosures & DistributionView details
ABB PSTX170-600-70 PSTX Softstarter 170 ASwitchgear, Enclosures & DistributionView details
ABB PSTX210-600-70 PSTX Softstarter 210 ASwitchgear, Enclosures & DistributionView details
ABB PSTX300-600-70 PSTX Softstarter 300 ASwitchgear, Enclosures & DistributionView details
ABB PSTX370-600-70 PSTX Softstarter 370 ASwitchgear, Enclosures & DistributionView details
ABB PSTX470-600-70 PSTX Softstarter 470 ASwitchgear, Enclosures & DistributionView details
ABB PSTX570-600-70 PSTX Softstarter 570 ASwitchgear, Enclosures & DistributionYou are viewing this model
Datasheets & Documents
  • PDF Datasheet ABB PSTX570-600-70 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.

ABB company profile

Formed 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50%
ASEA Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators
Brown, Boveri & Cie Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri
Headquarters Zurich, Switzerland; ABB Ltd became the group holding company in 1999
Ownership Public company listed on SIX Swiss Exchange and Nasdaq Stockholm
Brands in the group Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers
Product families Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots

Milestones

  • 1883: ASEA is founded in Västerås, Sweden.
  • 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
  • 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
  • 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
  • 2011 and 2017: Baldor Electric and B&R join ABB.
  • 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.

Choosing an ABB drive

ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.

Where ABB products are used

In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.

ABB products we list

Family Examples
AC drives ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module
Breakers, motor control and protection SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay
Flow measurement ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500
Pressure, temperature and level 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge
Analysers Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210
Control systems and actuators AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000

Ordering ABB products: what we need

Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.

Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.

Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.

FAQ

Questions about the ABB PSTX570-600-70 PSTX Softstarter 570 A

Answers from our engineering team on installation, compatibility and integration.

01What current range does the PSTX570-600-70 cover?
The catalog gives a setting range of 171.0 to 570.0 A for the PSTX570-600-70, with a rated operational current of 570 A.
02What supply voltages does the PSTX570-600-70 use?
The main circuit operates on 208 to 600 V, and the control supply is 100 to 250 V at 50 or 60 Hz.
03Does the PSTX570-600-70 have a built-in bypass?
Yes. The PSTX range has a built-in bypass; The catalog states that the integrated bypass of this size uses an AF370 contactor, rated 370 A in AC-3 at 400 V (200 kW, 300 hp at 480 V).
04Which communication does the PSTX570-600-70 support?
Modbus RTU on an RS485 interface is built in, and optional Anybus modules add other fieldbus protocols.
05How do I request a quotation for the PSTX570-600-70?
Send an RFQ with the part number PSTX570-600-70, quantity and delivery location in Oman or the GCC, and we will reply with availability and lead time.