Brand:

Advantech ADAM-4018+ 8-Channel Thermocouple Input Module

Description

Overview

Advantech ADAM-4018+ is an eight-channel thermocouple input module with Modbus, built for the ADAM-4000 family of RS-485 remote I/O. A pair of wires carries both power and data, so a string of these modules can sit in a marshalling cabinet or beside a furnace, reading temperatures and reporting to a PLC, SCADA gateway or industrial PC over a single multidrop line. The front label of the module prints its own range-code table: code 0E for type J, 0F for K, 10 for T, 11 for E, 12 for R, 13 for S, 14 for B and 07 for 4 to 20 mA, which is a handy check for a technician configuring it on site.

The unit uses the Modbus RTU protocol or Advantech’s ASCII command set, which makes it easy to add to an existing monitoring loop. Seven Star LLC is an independent supplier serving Oman and the GCC. Buyers in Oman generally need this module for kilns, boilers, heat exchangers and motor winding monitoring.

Why engineers choose Advantech ADAM-4018+

  • Eight differential input channels, each of them independently configurable, so a mixture of thermocouple types can share one module.
  • Thermocouple types J, K, T, E, R, S, B and N covered, plus 4 to 20 mA and plus or minus 20 mA current input.
  • Burnout detection for thermocouple channels, so a broken sensor wire is reported instead of read as a plausible temperature.
  • 3,000 VDC isolation, built-in TVS and ESD protection and plus or minus 35 VDC overvoltage protection.
  • Low power draw of 0.8 W at 24 VDC and a wide unregulated supply of 10 to 30 VDC.
  • Watchdog timer with a 1.6 second system and communication watchdog.

Specification table for Advantech ADAM-4018+

Model ADAM-4018+ (ordering code ADAM-4018+-F)
Function 8-channel thermocouple input module with Modbus
Input channels 8 differential, independent configuration
Input types Thermocouple and mA
Current input range Plus or minus 20 mA, 4 to 20 mA
Input impedance Voltage 20 megohm, current 120 ohm
Type J range 0 to 760 degrees Celsius
Type K range 0 to 1,370 degrees Celsius
Type T range minus 100 to 400 degrees Celsius
Type E range 0 to 1,000 degrees Celsius
Type R and S range 500 to 1,750 degrees Celsius
Type B range 500 to 1,800 degrees Celsius
Type N range minus 200 to 1,300 degrees Celsius
Resolution 16-bit
Sampling rate 10 samples per second, total
Accuracy Voltage mode 0.1 percent or better; current mode 0.2 percent or better
Common mode rejection at 50/60 Hz 120 dB
Normal mode rejection at 50/60 Hz 100 dB
Span drift Plus or minus 25 ppm per degree Celsius, typical
Zero drift Plus or minus 6 microvolt per degree Celsius
Isolation 3,000 VDC
Power Unregulated 10 to 30 VDC, 0.8 W at 24 VDC
Connectors 2 plug-in terminal blocks, 14 to 22 AWG
Protocols ASCII command and Modbus RTU
Operating temperature minus 10 to 70 degrees Celsius
Storage temperature minus 25 to 85 degrees Celsius
Humidity 5 to 95 percent RH

How Advantech ADAM-4018+ measures temperature

Thermocouples produce millivolt signals that are small compared with noise on a plant floor. With 120 dB common mode rejection and 100 dB normal mode rejection at mains frequency, the input stage is prepared for long cable runs near motors and variable speed drives. The sampling rate of 10 samples per second is the total for the module, so eight channels share that budget; for fast loops use fewer channels per module. Cold junction compensation, linearization and engineering unit scaling are handled by the module, and the host receives temperature values over Modbus rather than raw voltage counts. Check the user manual for the accuracy of each thermocouple range, because the datasheet refers to it for the thermocouple span.

Where Advantech ADAM-4018+ is used in Oman and the GCC

Typical jobs include furnace and oven profiling in metalworking, bearing and winding temperature monitoring on large pumps and compressors, flue gas temperature readings on boilers, and process temperatures in food and chemical plants. The Modbus RTU interface means the module can be polled by almost any PLC or DCS gateway used at oil and gas sites, power stations and desalination plants. The module is meant for indoor cabinet use, so allow a suitable enclosure for outdoor or very hot places beyond the 70 degree limit.

Wiring and signal integrity tips

Use thermocouple extension or compensating cable of the same type as the sensor all the way to the module terminals, because a copper joint in the middle of the run creates a second junction and a measurement error. Keep the sensor cables away from power conductors, and ground the shield at one end only. Input channels are differential, which helps rejecting pickup, but the best result still comes from short, tidy runs and a stable cabinet temperature near the terminals. When a channel is not used, leave it configured and open or shorted according to the user manual so that burnout detection does not generate nuisance alarms in the host software.

How ADAM-4018+ differs from other ADAM-4000 analog modules

The ADAM-4017+ is the eight-channel voltage and current module with ranges such as 0 to 10 V and 4 to 20 mA, using 1.2 W. The ADAM-4019+ is the universal eight-channel input that accepts thermocouples, millivolt, volt and milliamp signals channel by channel, using 1.0 W. The ADAM-4018+ is the thermocouple-focused variant at 0.8 W, with thermocouple ranges plus 4 to 20 mA current input. Choose it when most of your channels are thermocouples and you do not need volt-level inputs.

Installation and commissioning

Mount the module on a DIN rail or panel, wire the supply and RS-485 pair to the lower terminal block, and land the thermocouple leads on the upper terminals using the correct polarity and compensating cable. Set the address, baud rate and input type of each channel with the Advantech utility, then confirm readings against a calibrator. Keep the terminal block wiring within 14 to 22 AWG and shield the thermocouple cables.

Maintenance

There are no user-serviceable parts. Periodically verify the readings against a reference calibrator, review burnout alarms, and check terminal tightness. Keep a spare module of the same model in stores; the configuration is easy to restore because the settings are stored in the module and can be read back through the utility.

Ordering notes for Advantech ADAM-4018+

State the number of modules, the thermocouple types you will connect and the host protocol. Please note the ordering code ADAM-4018+-F listed by the manufacturer.

Related items you may also need: Advantech TPC-1551WP-E3AE Panel PC | Advantech ARK-3534B LGA1700 Expansion Fanless Box PC with PCIe Slots | Advantech ADAM-6017 8-Channel Analog Input Ethernet I/O Module | All Advantech products.

Documents and quotation

The manufacturer datasheet is shared by the ADAM-4017+, ADAM-4018+ and ADAM-4019+ modules and is attached to this page. Send an RFQ with the part number Advantech ADAM-4018+ and the quantity needed to receive a quotation.

Datasheets & Documents
  • PDF Datasheet Advantech ADAM-4018+ 8-Channel Thermocouple Input Module Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Advantech is the Taiwanese maker of industrial computers and IoT hardware: ADAM remote I/O modules, EKI industrial Ethernet switches and serial device servers, industrial PCs, panel PCs and embedded boards. It was founded in Taipei in 1983 by K.C. Liu and partners, and today Advantech Co., Ltd. is headquartered in Taipei and listed on the Taiwan Stock Exchange.

Seven Star LLC supplies Advantech automation products to system integrators and plant teams in Oman, and this page lists items such as an ADAM-6000 Ethernet I/O module, an ADAM-4000 serial converter and an IPC rackmount chassis.

Advantech company profile

Founded 1983, Taipei, Taiwan
Founder K.C. Liu and partners
Headquarters Taipei, Taiwan
Ownership Advantech Co., Ltd., public company listed on the Taiwan Stock Exchange
Product families ADAM-4000 and ADAM-6000 remote I/O, EKI managed and unmanaged switches and serial device servers, industrial PCs and rackmount computers, panel PCs, embedded boards and edge gateways

Advantech ADAM and IPC products listed here

The ADAM-6017 is an 8-channel analog input module from the ADAM-6000 Ethernet I/O family. It brings voltage and current signals onto a network and is read by SCADA or PLC software over Modbus TCP. The ADAM-4520 belongs to the ADAM-4000 serial family and converts RS-232 to isolated RS-422 or RS-485, a common fix for linking a PC or panel to field devices. The IPC-623 is a 4U, 20-slot rackmount chassis that houses a backplane, CPU card and expansion cards for control room computers.

Advantech products we list

Family Examples
Industrial Communications ADAM-4520 Isolated RS-232 to RS-422/485, ADAM-4571 1-Port RS-232/422/485 Serial Device, ECU-1152 Industrial Communication Gateway, EKI-2528 8-Port Unmanaged Industrial Ethernet, EKI-2725 5-Port Gigabit Unmanaged Industrial, EKI-5710E 10-Port Managed Industrial Ethernet, EKI-7710E-2CI 8FE+2G Combo Managed Redundant
Industrial Computers ARK-3534B LGA1700 Expansion Fanless Box PC, IPC-610-L 4U 15-Slot Rackmount Industrial, IPC-623 Industrial 4U Rackmount Chassis, TPC-1051WP-E3AE Panel PC, TPC-1551WP-E3AE Panel PC, UNO-1372G Atom Quad-Core DIN-Rail Control PC, UNO-2484G V2 Modular Fanless Box PC with 4 x
PLC & I/O Cards ADAM-4017+ 8-Channel Analog Input Module, ADAM-6017 8-Channel Analog Input Ethernet I/O, ADAM-6050 12DI/6DO Ethernet Digital I/O Module
Controllers & Data Acquisition ADAM-4055 16-Channel Isolated Digital I/O, ADAM-4150 Robust 15-Channel Digital I/O

Ordering Advantech hardware: what we need

Send the full part number with its suffix. Advantech adds letters after the model, as in ADAM-6017-D, to mark the hardware revision, and existing configurations sometimes depend on it. For an IPC chassis, state the backplane, power supply and drive bay arrangement, since these are ordered as specific versions. We supply across the GCC and check part numbers against Advantech documentation.

Facts checked against Advantech's published corporate profile, October 2026.

FAQ

Questions about the Advantech ADAM-4018+ 8-Channel Thermocouple Input

Answers from our engineering team on installation, compatibility and integration.

01How many channels does the Advantech ADAM-4018+ have?
It has 8 differential input channels, and each channel can be configured independently, which allows different thermocouple types on the same module.
02Which thermocouple types does the ADAM-4018+ support?
The datasheet lists J, K, T, E, R, S, B and N types, with temperature ranges such as 0 to 1,370 degrees Celsius for type K.
03What communication protocols does the ADAM-4018+ use?
It supports ASCII commands and Modbus RTU over RS-485, so it can be polled by PLCs, SCADA gateways and industrial PCs.
04What power supply does the ADAM-4018+ need?
An unregulated 10 to 30 VDC supply; the module consumes 0.8 W at 24 VDC according to the datasheet.
05What isolation and protection does the ADAM-4018+ have?
It provides 3,000 VDC isolation, built-in TVS and ESD protection and plus or minus 35 VDC overvoltage protection.