- Automation & ControlView all 3,068 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Metrohm
Metrohm 781 pH/Ion Meter Laboratory Ion Analyzer
Description
Overview
The Metrohm 781 pH/Ion Meter is the top model of Metrohm’s classic laboratory pH meters. On top of pH, millivolt and temperature measurement it determines ion concentrations with ion-selective electrodes, either from a calibration curve or by standard or sample addition. Seven Star LLC is an independent supplier serving Oman and the GCC. Facts below come from the Metrohm brochure for the 780 and 781 and the product page for article 2.781.0010.
Ion measurement with the 781 pH/Ion Meter
Three modes are available for ion work: direct measurement against a calibration curve, standard addition and sample addition. For the direct mode up to 19 standards can be used, and the meter evaluates the curve automatically. The result can carry any name the user chooses, and the unit is freely selectable. With a Dosimat plus attached, both calibration and additions become automatic: the user enters the concentration of the standard and the number of addition steps, and the instrument handles the rest. That raises precision and removes a good deal of pipetting from the day.
Electrodes that fit the Metrohm 781 pH/Ion Meter meter
Metrohm lists the following ion-selective Metrosensor electrodes for the meter. With crystal membrane: fluoride, chloride, lead, copper, silver, sulfide, cyanide, iodide, bromide, cadmium and thiocyanate. With polymer membrane: sodium, calcium, nitrate and potassium. With glass membrane: sodium. Ordinary pH work uses the supplied 6.0258.600 Unitrode with integrated Pt1000 temperature sensor.
Measuring data of Metrohm 781 pH/Ion Meter
| Item | Value |
|---|---|
| pH range | 0 to 14 display, 20.000 pH calculable |
| Potential range | plus or minus 2200 mV |
| Temperature range, Pt1000 | minus 150.0 to plus 250.0 degrees C |
| Temperature range, NTC | minus 20.0 to plus 250.0 degrees C |
| Resolution | 0.001 pH; 0.1 mV; 0.1 degrees C |
| pH calibration | 1 to 9 buffers with automatic buffer recognition |
| Memory | method memory; up to 100 measured value data sets |
| Dialog languages | English, German, French, Spanish |
| Interfaces | RS-232C for printer or PC; MSB for stirrer; PC keyboard and barcode reader; remote for sample changer |
| Power supply | 100 to 240 V, 50 to 60 Hz (12 V DC adapter) |
| Supplied electrode | 6.0258.600 Unitrode with integrated Pt1000 |
| Concentration range | ten to the power of minus 37 up to ten to the power of 38 |
| Calibration standards for ion mode | up to 19 |
| Ion modes | direct measurement, standard addition, sample addition |
| Automation | Dosimat plus for calibration and additions (option) |
Quality functions inherited from the 780 line
The 781 keeps the GLP-compliant electrode test, the nine-buffer pH calibration with automatic buffer recognition, calibration and service interval monitoring, user identification on printouts and an automatic self-diagnosis at switch-on. The plot function shows pH, millivolts, temperature and concentration against time, the last of which only the 781 provides. A memory holds up to 100 measured data sets, and sample names of up to 15 characters can be typed on a PC keyboard or scanned from a barcode, so results always carry the right identity when they are printed or transferred to a computer for further evaluation.
How 781 pH/Ion Meter differs from the 780 pH Meter
If a laboratory only measures pH, the 780 is the sensible choice. The 781 is for labs where chloride in process water, fluoride in drinking water, nitrate in fertilizer solutions or sodium in boiler water must also be determined. Hardware, ranges, resolution and interfaces are the same; the difference is the concentration mode and the associated automation with a Dosimat plus.
Uses in Oman and the GCC
Desalination plants watch chloride, fluoride and sodium; fertilizer producers track nitrate and potassium; electroplating shops measure cyanide and copper; dairies check salt. An ion meter answers these questions faster and more cheaply than a full chromatograph when only one or two ions are of interest. The 781 stores methods under meaningful names, which helps when several analysts share the instrument in a busy shift laboratory and each wants his own sample series ready.
Ion-selective measurement in practice
Ion work is sensitive to preparation. Total ionic strength adjustment buffer is normally added to standards and samples so that activity effects are the same in both, temperature must be steady, and the electrode needs time to respond at low concentrations. The 781 supports this with stirrer control, a plot of concentration against time that shows when the signal has stabilised, and storage of the calibration data per electrode. Sample addition is useful when the matrix is complex, because the same sample provides both the baseline and the spiked readings and so matrix errors partly cancel. Standard addition suits unknown matrices in the same way, and automation with a Dosimat makes the additions precise and repeatable.
Choosing the right accessories
Plan the bench around the work. For occasional ion measurements a magnetic stirrer and a stand are enough. For dozens of determinations a week, add a Dosimat plus with its 20 mL Exchange Unit so that standard additions run unattended, and connect the Custom printer so that every calibration and result is documented on paper. The brochure also lists a remote box for attaching a 25-pin cable together with an MSB cable, and the dedicated cable between the 781 and the Dosimat plus. Where a sample rack is needed, the 869 Compact Autosampler is the combination Metrohm recommends for both meters.
Installation and routine work
Mount the stand rod and electrode holder, fit the electrode, attach the stirrer to the MSB socket, and connect the Dosimat plus through the dedicated cable if automatic additions are planned. Calibrate the ion electrode with fresh standards in the right concentration order, from low to high, and check slope and response time. Condition and store ion-selective membranes as the electrode instructions describe, because a dry or fouled membrane is the commonest cause of drifting results.
Related items you may also need: Metrohm 2035 Process Analyzer | Metrohm 916 Ti-Touch Compact Potentiometric Titrator | Metrohm 905 Titrando Potentiometric Titrator | All Metrohm products.
Before you order the Metrohm 781 pH/Ion Meter
- To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Metrohm 781 pH/Ion Meter code on this page.
- The quotation for the Metrohm 781 pH/Ion Meter states the confirmed code and the lead time to site.
- The attached manufacturer datasheet covers the Metrohm 781 pH/Ion Meter ratings, dimensions and installation details.
- Delivery of the Metrohm 781 pH/Ion Meter is arranged to project sites in Oman and across the GCC, alongside the rest of our liquid analytical systems range.
- A spare Metrohm 781 pH/Ion Meter on the shelf is a simple way to protect critical service from long lead times.
Documents and quotation
The Metrohm brochure for the 780 pH Meter and Metrohm 781 pH/Ion Meter is attached to this page. Please send your RFQ with the model name, the article number, quantity, the ion-selective electrodes and accessories needed, and your delivery location in Oman or the GCC.
Other Models in the PHmeter Range
Seven Star LLC supplies models from the PHmeter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Metrohm 780 pH Meter Benchtop pH and mV Instrument | Liquid Analytical Systems | View details |
| Metrohm 781 pH/Ion Meter Laboratory Ion Analyzer | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Metrohm 781 pH/Ion Meter Laboratory Ion Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.
Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.
Metrohm company profile
| Founded | 1943, Herisau, Switzerland |
|---|---|
| Founder | Bertold Suhner |
| Headquarters | Herisau, Switzerland |
| Ownership | Metrohm Foundation |
| Product families | Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes |
Metrohm instruments listed here
The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.
Metrohm products we list
| Family | Examples |
|---|---|
| Liquid Analytical Systems | 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr… |
Ordering Metrohm equipment: what we need
Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.
Facts checked against Metrohm's published company history, October 2026.
Browse Metrohm products by category: Liquid Analytical Systems.
FAQ
Questions about the Metrohm 781 pH/Ion Meter Laboratory Ion Analyzer
Answers from our engineering team on installation, compatibility and integration.
01Which ions can the Metrohm 781 pH/Ion Meter measure?
Metrohm lists Metrosensor electrodes for fluoride, chloride, lead, copper, silver, sulfide, cyanide, iodide, bromide, cadmium, thiocyanate, sodium, calcium, nitrate and potassium.
02How many standards can the 781 use for calibration?
Up to 19 standards can be used for a direct measurement calibration, and the calibration curve is evaluated automatically by the instrument.
03What ion measuring modes does the 781 have?
Direct measurement, standard addition and sample addition, with the additions automatable through an attached Dosimat plus.
04What is supplied with article 2.781.0010?
The pH/Ion Meter with a 6.0258.600 Unitrode pH electrode, a stand rod with base and electrode holder, and a line adapter for 100 to 240 V.
05How does the Metrohm 781 differ from the 780?
They share ranges and interfaces; the 781 adds concentration mode with up to 19 standards and standard or sample additions that the 780 does not offer.


















Reviews
There are no reviews yet.