The Metrohm 888 Titrando is a potentiometric titrator from Metrohm, built around intelligent dosing and sensor technology so that every titration can be traced back to the exact titrant cylinder and electrode that produced it. Seven Star LLC is an independent supplier serving Oman and the GCC. The manufacturer’s brochure for the 888 and 890 Titrando covers both models, and this page concentrates on the 888, the potentiometric version, rewriting the brochure for laboratory managers in refineries, water utilities, petrochemical plants and quality control labs.

Titration is still the workhorse method for acid number, base number, chloride, hardness, alkalinity and many other determinations. What separates one titrator from another is not the chemistry but the safeguards around it: whether the titer is current, whether the electrode is calibrated, and whether a method change is recorded. The Metrohm 888 Titrando puts those safeguards in the instrument.

Intelligent dosing and sensors in the Metrohm 888 Titrando

Each Exchange Unit carries a data chip. The titrator reads from it the titrant type, titer, date of the last titer determination, shelf-life data and more, compares them with the selected method and refuses to start if the values do not fit. Each unit has serial and cylinder numbers and its own certificate. The Exchange Unit offers 20,000 increments per cylinder volume. A similar chip sits in the iTrodes, Metrohm’s intelligent electrodes, storing article and serial numbers, calibration data, calibration history, working life and validity period. When the electrode is plugged in, the data are read automatically, mix-ups are avoided, and an electrode calibrated on another instrument can be moved without recalibration. The 888 also accepts conventional analog sensors, so existing electrodes remain usable.

Technical overview for Metrohm 888 Titrando

Feature Published information
Instrument type Potentiometric titrator; Karl Fischer version is the 890 Titrando
Dosing element One integrated Dosimat for the Exchange Unit; a further titration buret (800 Dosino or 805 Dosimat) possible with OMNIS
Resolution of dosing 20,000 increments per cylinder volume
Measuring input One interface for pH, U/mV, T/degrees C, intelligent iTrodes; differential amplifier optional
Temperature sensor Pt1000 or NTC
Titration modes DET, MET, SET, MEAS and CAL; KFT volumetric Karl Fischer with OMNIS
Operation 900 Touch Control with colour screen, or OMNIS Software on a PC
Stirrer and stand 801 or 802 Stirrer with 804 Ti Stand; 803 Ti Stand for KF
Automation One sample changer via USB, for example 814 USB Sample Processor or 815 Robotic USB Sample Processor XL
Connections Four MSB connections, two USB slave ports, USB interfaces for printer, keyboard, barcode reader and balances
Compliance GLP and GMP functions; complies with FDA 21 CFR Part 11 with Touch Control or OMNIS
Ordering codes 2.888.0010 888 Titrando; 2.888.0110 with Touch Control

How 888 Titrando differs from other Metrohm titrators

The 890 Titrando in the same brochure is the Karl Fischer variant, with a measuring input for polarizable electrodes and conditioning for water determination. The entry-level 848 Titrino plus has a 10,000-step Exchange Unit and no iTrode interface, while the Metrohm 888 Titrando resolves 20,000 steps per cylinder and supports intelligent electrodes. It also offers dynamic and monotonic equivalence-point titration, titration to preset endpoints and real-time curve display, and can run additional dosing elements under OMNIS. Choose the 888 when traceability and automation matter more than purchase simplicity.

Using the 888 Titrando in Oman and the GCC

Gulf laboratories use potentiometric titration for the acid and base number of lubricants and crude, chloride in desalination feed and boiler water, alkalinity and hardness of water supplies, and a wide range of food and pharmaceutical assays. The sample processors connect through USB, so a laboratory handling many samples can run overnight. Standard user methods help new technicians get started, and templates for methods and calculation formulas support in-house procedures.

Quality management features

The brochure lists an auto-diagnostic test after switching on, monitoring of validation and service intervals, calibration data of sensors, titers and results, documentation of every method change, and strict control of access rights with login and password. Methods can carry names of up to 32 characters and be stored in structured directories. Data can be saved on the instrument, on a USB stick or on a PC, and the Touch Control can export results as PDF to a network location or to a LIMS.

Why traceability matters in a titration laboratory

When a result is questioned, the first thing an auditor asks is which titrant, which titer and which electrode were used. In many labs that information lives in a notebook or a spreadsheet and is easily wrong. The Metrohm 888 Titrando stores it with the result because the instrument itself read it from the data chips. This reduces repeated determinations caused by an expired titer, prevents the wrong electrode from being used for a method, and makes it much easier to show regulators or customers that a result was produced under controlled conditions. The monitoring functions for validation and service intervals also give the laboratory manager an early warning before a certificate lapses, instead of discovering the problem during an audit. For laboratories that run both potentiometric and Karl Fischer work, using the same Titrando platform for both reduces training time, because the Touch Control screens, method structure and sample changer connections are the same.

Installation and care of Metrohm 888 Titrando

Install the titrator on a vibration-free bench, connect the stirrer and stand, fit the Exchange Unit and electrode, and let the instrument read their chips. Rinse the buret and tubing when changing titrant, calibrate the electrode at the interval set in the method and keep titers current. Follow the manual for service intervals.

Ordering notes for 888 Titrando

State whether you need the bare instrument or the version with Touch Control, and list stirrer, stand, electrodes and Exchange Units for the methods you run. Confirm the full configuration with the supplier before ordering.

Related items you may also need: Metrohm 905 Titrando Potentiometric Titrator | Metrohm 916 Ti-Touch Compact Potentiometric Titrator | Metrohm 2035 Process Analyzer | All Metrohm products.

Documents and quotation

The manufacturer’s 888/890 Titrando brochure is attached to this page as a datasheet. Send your RFQ with Metrohm 888 Titrando, ordering code, quantity and delivery location in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet Metrohm 888 Titrando Potentiometric Titrator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.

Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.

Metrohm company profile

Founded 1943, Herisau, Switzerland
Founder Bertold Suhner
Headquarters Herisau, Switzerland
Ownership Metrohm Foundation
Product families Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes

Metrohm instruments listed here

The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.

Metrohm products we list

Family Examples
Liquid Analytical Systems 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr…

Ordering Metrohm equipment: what we need

Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.

Facts checked against Metrohm's published company history, October 2026.

FAQ

Questions about the Metrohm 888 Titrando Potentiometric Titrator

Answers from our engineering team on installation, compatibility and integration.

01What kind of titrator is the Metrohm 888 Titrando?
It is a potentiometric titrator with an intelligent Exchange Unit dosing element and an interface for pH, mV and temperature sensors including iTrodes.
02How fine is the dosing of the Metrohm 888 Titrando?
The Exchange Unit offers 20,000 increments per cylinder volume and carries a data chip with titrant, titer and shelf-life data.
03How is the 888 Titrando operated?
It is operated with the 900 Touch Control colour screen or with OMNIS Software on a PC, and it supports FDA 21 CFR Part 11 compliance.
04What is the difference between the 888 and 890 Titrando?
The 888 is for potentiometric titration, while the 890 is the Karl Fischer titrator with a measuring input for polarizable electrodes.
05Can the 888 Titrando be automated?
Yes. A sample changer such as the 814 USB Sample Processor or 815 Robotic USB Sample Processor XL connects through USB.