Metrohm 860 KF Thermoprep Karl Fischer Sample Oven
Description
Overview
The Metrohm 860 KF Thermoprep is a heated oven that prepares samples for Karl Fischer titration when the water cannot be reached by direct injection into the cell. Samples are weighed into sealed vials, warmed in the oven, and the moisture that evaporates is carried by dry gas into a titration cell where a coulometric or volumetric titrator measures it. Seven Star LLC is an independent supplier serving Oman and the GCC. The text below follows the Metrohm leaflet for the 860 and the product page for article 2.860.0010.
Why an oven is sometimes the only practical route
Plenty of materials look simple but refuse to behave in a Karl Fischer cell. Metrohm names five typical problems: the sample releases its water only slowly, it releases it only at high temperature, it dissolves poorly in alcohols, it undergoes side reactions with the KF solution, or it contaminates the cell and the electrodes. Plastics, salts, oils with additives, powders and many foods fall into these groups. Heating the sealed vial moves the water into the gas phase, leaving the matrix behind. Since no solubilisers are needed, matrix effects and secondary reactions disappear and the cell stays clean.
Working steps with the Metrohm 860 KF Thermoprep
- Weigh the sample into a vial and close it airtight with an aluminium septum cap.
- Bring the oven to the chosen temperature and condition the titration cell.
- Place the vial in the oven so the needle pierces the septum.
- Start the determination on the connected coulometer or titrator.
- Remove the vial when the titration has ended.
A needle support guides the needle so that it always hits the septum, and the transfer line is heated so that released moisture arrives quantitatively in the cell instead of condensing on the way.
Characteristics of the Metrohm 860 KF Thermoprep
| Item | Value |
|---|---|
| Function | manual thermal sample preparation for Karl Fischer titration |
| Dimensions W/H/D | 440 / 500 / 230 mm |
| Sample container | hermetically sealed sample vials; 6 mL vials listed as accessory |
| Transfer line | heated outlet tubing |
| Needle guidance | needle support prevents the needle landing outside the septum |
| Titrator compatibility | volumetric or coulometric KF titrators |
| Operation | control unit with a clearly structured menu |
| Optional modification | oven adapted for customer’s own production vials |
| Article number | 2.860.0010 |
| Accessories listed | aluminium septum caps 1000 pieces, needle support, 6 mL vials 1000 pieces |
Sample vials and septa
The accessories in the leaflet give a sense of the consumables: aluminium septum caps are sold in packs of 1000, 6 mL vials in packs of 1000, and a replaceable needle support keeps the needle centred. Vial size matters because the headspace and the amount of material influence how fast the water leaves the sample. Smaller vials heat quickly and suit low sample masses, while a custom vial adaption lets a plant use the same containers it uses on the production line, which makes it easier to correlate laboratory results with process samples. Septa must be fresh enough to reseal after puncture, and caps need crimping tightly so that no ambient humidity leaks in.
Matching titrators
The leaflet lists the 851 and 852 Titrando, the Eco Coulometer, the 917 Coulometer and the 915 KF Ti-Touch as ordering options to pair with the oven. Low water contents call for a coulometric cell; higher contents suit a volumetric unit. In practice a laboratory chooses the titrator according to the expected moisture and the oven according to how many vials per day must be run. Samples in the trace range, such as polymer pellets for extrusion, belong with a coulometer, while moist powders suit the volumetric route.
How 860 KF Thermoprep differs from the 885 and 874
The 860 is the manual member of the oven family: each vial is placed in the oven by hand, and the footprint is 440 by 230 mm. The 885 Compact Oven Sample Changer takes the same task to an automated changer, and the product page states samples can be heated to 250 degrees C in it. The 874 Oven Sample Processor is intended for high sample throughput. Pick the 860 when the day brings a handful of oven samples; step up when the vial queue grows.
Uses across Oman and the GCC
Polymer compounders, cable plants, pharmaceutical packers and lubricant blenders in the region regularly need water figures on materials that cannot go into the cell directly. Oven preparation also removes the need to purchase large volumes of special solvents, which simplifies storage and disposal at sites where hazardous chemicals are tightly controlled. Typical test items are plastic granules, cable insulation, powders, and salts of limited solubility.
Choosing the oven temperature
There is no universal setting. The right temperature is high enough to drive out the water within a reasonable time yet below the point at which the matrix itself decomposes and releases water or other volatile compounds that react with iodine. Method developers usually run a short series at stepped temperatures, watch the extraction curve, and select the lowest temperature that gives a stable plateau and reproducible results. Document this choice in the method together with the vial size, sample mass, carrier gas flow and the end criterion used on the titrator.
Installation and routine care
Connect the carrier gas line with a drying cartridge, route the heated transfer tubing to the cell inlet, and let temperature settle before the first vial. Run a blank vial at the chosen temperature to establish the background moisture, and subtract it according to your method. Replace septa regularly because a damaged septum leaks and falsifies the result, and keep spare vials and caps on hand.
Related items you may also need: Metrohm 2035 Process Analyzer | Metrohm 916 Ti-Touch Compact Potentiometric Titrator | Metrohm 905 Titrando Potentiometric Titrator | All Metrohm products.
Before you order the Metrohm 860 KF Thermoprep
- To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Metrohm 860 KF Thermoprep code on this page.
- The quotation for the Metrohm 860 KF Thermoprep states the confirmed code and the lead time to site.
- The attached manufacturer datasheet covers the Metrohm 860 KF Thermoprep ratings, dimensions and installation details.
- Delivery of the Metrohm 860 KF Thermoprep is arranged to project sites in Oman and across the GCC, alongside the rest of our liquid analytical systems range.
- A spare Metrohm 860 KF Thermoprep on the shelf is a simple way to protect critical service from long lead times.
Documents and quotation
The Metrohm leaflet for the Metrohm 860 KF Thermoprep, with the measuring procedure and ordering list, is attached to this page. Please send your RFQ with the model name, quantity, the titrator you plan to combine it with and your delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Metrohm 860 KF Thermoprep Karl Fischer Sample Oven Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.
Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.
Metrohm company profile
| Founded | 1943, Herisau, Switzerland |
|---|---|
| Founder | Bertold Suhner |
| Headquarters | Herisau, Switzerland |
| Ownership | Metrohm Foundation |
| Product families | Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes |
Metrohm instruments listed here
The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.
Metrohm products we list
| Family | Examples |
|---|---|
| Liquid Analytical Systems | 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr… |
Ordering Metrohm equipment: what we need
Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.
Facts checked against Metrohm's published company history, October 2026.
Browse Metrohm products by category: Liquid Analytical Systems.
FAQ
Questions about the Metrohm 860 KF Thermoprep Karl Fischer Sample Oven
Answers from our engineering team on installation, compatibility and integration.
01What is the Metrohm 860 KF Thermoprep used for?
It prepares samples thermally for Karl Fischer titration, heating sealed vials so that the evaporated water is carried by dry gas into a coulometric or volumetric titration cell.
02Which samples need the KF oven method?
Metrohm lists samples that release water slowly or only at high temperature, dissolve poorly in alcohols, react with KF solutions, or contaminate the cell or electrodes.
03Which titrators does the 860 KF Thermoprep pair with?
The leaflet lists the 851 and 852 Titrando, Eco Coulometer, 917 Coulometer and 915 KF Ti-Touch, and any volumetric or coulometric KF titrator can analyse the samples.
04What are the dimensions of the Metrohm 860 KF Thermoprep?
The product page gives 440 mm width, 500 mm height and 230 mm depth for article 2.860.0010.
05Can the oven take my own production vials?
Yes, Metrohm states that the oven can be modified as an option so that vials used in your own plant can be used instead of the standard sample vials.