Brand: Victaulic
Victaulic Series 721 Vic-Ball Grooved Ball Valve 800 psi
Description
Overview
Victaulic Series 721 is the Vic-Ball valve, a standard port, end entry ball valve with grooved ends, designed for 800 psi WOG service (5515 kPa). The datasheet in our file lists the 4 inch and 6 inch sizes, with ductile iron body and end cap, a micro finished nickel plated steel ball and stem and a reinforced TFE seat. It is a heavy duty, quarter turn isolation valve for steel piping that is joined with grooved couplings instead of flanges. Seven Star LLC is an independent supplier serving Oman and the GCC.
Design of Victaulic Series 721
A standard port design means the ball bore is slightly smaller than the pipe, which keeps the valve compact and light while still giving a streamlined flow path. The valve is end entry: the ball and seats are installed through the end cap, so the body is a single casting with no split line in the middle of the pressure boundary. The body and end cap are ductile iron to ASTM A536 and the body is painted with black enamel. The ball and stem are nickel plated carbon steel, stem nuts and washers are electrogalvanized steel and the handle is ductile iron to the same standard. Seals are reinforced tetrafluoroethylene, rated to 450 degrees F (232 degrees C), though the datasheet adds that the real fluid temperature is limited by the gaskets of the Victaulic couplings used at the ends.
Datasheet figures for Victaulic Series 721
| Item | Datasheet value |
|---|---|
| Rating | 800 psi WOG, 5515 kPa |
| Port | Standard port, end entry |
| Sizes in this publication | 4 inch (DN100) and 6 inch (DN150) |
| Body and end cap | Ductile iron ASTM A536, painted black enamel |
| Ball and stem | Nickel plated carbon steel |
| Seat and seals | Reinforced TFE, rated to 450 degrees F, 232 degrees C |
| Handle | Ductile iron ASTM A536; pinned extensions available |
| 4 inch end to end | 8.25 inch, 210 mm |
| 4 inch height | 6.92 inch, 176 mm; weight 32.4 lb, 14.7 kg |
| 6 inch end to end | 10.10 inch, 257 mm |
| 6 inch height | 9.14 inch, 232 mm; weight 75.0 lb, 34.0 kg |
| Cv full open, 4 inch | 815 gpm per 1 psi drop, 3085 l per minute |
| Cv full open, 6 inch | 1500 gpm per 1 psi drop, 5678 l per minute |
| Option | Stainless steel body, see Victaulic section 17.02 |
Operating torque and flow data
The datasheet includes a torque chart derived from water tests at ambient temperature, plus guidance on service factors. Its remark that a ball valve left static for hours needs extra breakaway torque, with a factor between 2 to 1 and 3 to 1, is worth keeping in mind when sizing gear operators or actuators. Flow capacity is given as Cv with the valve fully open: 815 for the 4 inch size and 1500 for the 6 inch size, so pressure drop at design flow can be calculated from the formula printed on the page, where flow equals Cv times the square root of the pressure drop.
How Victaulic Series 721 differs from the other Vic valves
The Series 700 butterfly valve stops at 200 psi, and the Series 377 Vic-Plug is a throttling valve that seals up to 175 psi. The Victaulic Series 721 sits well above both with 800 psi WOG and a full ball closure, so it is the natural pick for high pressure shutoff, fire pump discharge lines and process water headers, but it is not a balancing or throttling valve. Compared with the brass Series 722 for small threaded lines, it is a large bore valve for grooved pipe, and unlike the 722 it is not meant for steam.
Typical use in Oman and the GCC
Large grooved ball valves are chosen for high pressure water lines in desalination plants, boiler feed and cooling water systems, offshore utility piping and fire water pump headers where a positive shutoff is needed. The compact end to end length helps in crowded pipe racks and pump rooms.
Installation guidance
Install the valve with matching grooved couplings and make sure the pipe ends are grooved to publication 25.01. Close and open the valve once before pressure is applied. Support the line on both sides, because at 32 to 75 pounds the valve is a significant load. Keep the handle clear of obstructions, and use a pinned extension only when space or height demands it, since longer levers can overload the stem.
Inspection and maintenance
Exercise the valve regularly, particularly if it is a seldom used isolation point. Look for weeping at the stem and the end cap joint, and for stiffness that shows scale or debris in the seat. Because the seat and seals are PTFE based, avoid abrasive fluids and open the valve gradually after long periods of shutdown.
Selection notes
State the pipe size, working pressure, medium and temperature. Ask for the stainless steel body if the water is aggressive or if corrosion in the pipe room is a problem. Confirm that the couplings you plan to use have gaskets that match the fluid, since they limit the system temperature.
Why an end entry ball suits high pressure service
In the Victaulic Series 721, the single piece body keeps all of the pressure in one casting, and the removable end cap lets the seat and ball be serviced without cutting the line apart. The nickel plated ball is micro finished, which reduces friction against the TFE seat and gives smooth, repeatable operation over many cycles. The valve closes with a quarter turn of the handle, so the position is visible at a glance from the handle direction: in line with the pipe means open and across the pipe means closed. In a plant where operators must isolate a pump quickly in an emergency, that single clear movement is a real advantage compared with a multi turn gate valve, and the grooved ends make later removal for service quick because only two couplings have to be released.
Related items you may also need: Victaulic Series 761 Vic-300 MasterSeal Butterfly Valve | Victaulic FireLock Series 705 Butterfly Valve, Supervised Open | Victaulic Style 07 Zero-Flex Rigid Coupling | All Victaulic products.
Specifying the right Victaulic Series 721 size and gasket
The Victaulic Series 721 is a product style that is supplied in many sizes and material combinations, so a single order line is defined by the details below rather than by the style name alone.
- Nominal size of the Victaulic Series 721 and the pipe outside diameter it must fit (IPS or metric).
- Pipe end preparation: roll grooved, cut grooved or plain end, and the pipe material.
- Body and trim materials, seat or seal elastomer grade, and the fluid and temperature it must handle.
- Working pressure required and any approval needed for the service, for example fire protection listings.
- Operator or accessory options, such as lever, gear operator, tamper switch or test and drain fittings, where the valve offers them.
Send these details, or the Victaulic part number from an existing installation or drawing, and the quotation will confirm the exact orderable item and the matching gasket.
Documents and quotation
The Victaulic publication 08.14 for the Victaulic Series 721 is attached and has the dimensions, Cv table and torque chart. Send your RFQ with the Victaulic Series 721 size, quantity and delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Victaulic Series 721 Vic-Ball Grooved Ball Valve 800 psi Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Victaulic is an American maker of grooved mechanical pipe joining systems, valves and fire protection products, headquartered in Easton, Pennsylvania. Its grooved coupling was patented in 1919 by Ernest Tribe, and the name combines 'victory' and 'hydraulic'. Victaulic is privately held and reinvests in its own plants and technology.
Seven Star LLC lists Victaulic couplings and butterfly valves, among them the Style 107N QuickVic rigid coupling, and supplies Victaulic couplings and fittings for mechanical, utility and process piping in Oman on inquiry.
Victaulic company profile
| Origins | 1919, grooved coupling patent |
|---|---|
| Name | From 'victory' and 'hydraulic' |
| Headquarters | Easton, Pennsylvania |
| Ownership | Privately held |
| Product families | Style 07, 77 and 107N grooved couplings, Vic-300 MasterSeal butterfly valves, FireLock fire protection valves and sprinklers, grooved fittings and tools |
Milestones
- 1919: The grooved Victaulic coupling is patented.
- 2019: Victaulic marks 100 years.
Victaulic Style 107N QuickVic couplings
The Style 107N is a rigid coupling for roll-grooved or cut-grooved carbon steel and stainless steel pipe in sizes from 2 to 12 inches (DN 50 to DN 300). Victaulic rates it from full vacuum up to 750 psi (5171 kPa), but the working pressure of a given joint depends on pipe material, wall thickness and size. The housing has an angled bolt pad that makes the joint rigid, and a galvanized finish is optional.
Where Victaulic couplings are used and what to send
The manufacturer names HVAC, utility and process piping as the applications for this style. For an inquiry, send the style number, nominal size, pipe material and schedule, the fluid and temperature so the gasket grade can be checked, the housing finish and the quantity. GCC consultants often ask for the submittal sheet, which we provide from the manufacturer.
Facts checked against Victaulic's 100-year innovation timeline, October 2026.
Browse Victaulic products by category: Pipes & Fittings.
Victaulic products we list
FAQ
Questions about the Victaulic Series 721 Vic-Ball Grooved Ball Valve
Answers from our engineering team on installation, compatibility and integration.
01What is the pressure rating of Victaulic Series 721?
The datasheet describes it as designed for 800 psi WOG service, which is 5515 kPa.
02What sizes of Victaulic Series 721 are in the datasheet?
The publication lists 4 inch DN100 and 6 inch DN150, both standard port with grooved ends.
03What is the Cv of Victaulic Series 721?
Full open Cv is 815 gpm for the 4 inch size and 1500 gpm for the 6 inch size, per 1 psi pressure drop.
04What is the seat material of Victaulic Series 721?
The seat and seals are reinforced TFE, rated to 450 degrees F or 232 degrees C, though coupling gaskets may limit the service.
05Is a stainless steel body available for Victaulic Series 721?
The datasheet notes that a stainless steel body is also available and refers to Victaulic section 17.02 for details.