Brand: Metrohm
Metrohm 899 Coulometer for Karl Fischer Water Determination
Description
Overview
Water content decides whether a transformer oil can stay in service, whether a lubricant meets its specification, and whether a pharmaceutical powder is stable. At trace level the standard method is coulometric Karl Fischer titration, and the Metrohm 899 Coulometer is Metrohm’s smallest and most compact instrument for it. Seven Star LLC is an independent supplier serving Oman and the GCC. The brochure for the 899 Coulometer, edition 2019, states that the instrument takes no more bench space than a sheet of A4 paper, and the notes below rework it for laboratories and field teams.
Compact design of the Metrohm 899 Coulometer
The instrument measures 144 x 112 x 282 mm in width, height and depth, without the titration cell holder. It includes an integral magnetic stirrer, so no external stirrer needs to be connected, and an integral holder keeps the titration cell standing securely on top, so no support rod is needed. Despite its size, the brochure claims no compromise in performance, with water contents determined to trace level, over a range of 10 micrograms to 200 milligrams.
An optional Power Box holds rechargeable batteries that give hours of uninterrupted operation, so the instrument can be used in the field without a mains socket. That makes it relevant for site checks of oil or solvent samples where waiting for laboratory results would cost time.
Specification table for Metrohm 899 Coulometer
| Item | Published information |
|---|---|
| Water content range | 10 micrograms to 200 milligrams |
| Predefined user methods | 3 |
| Stored user methods | Up to 100 |
| Dialog modes | Routine and expert |
| Stirrer | Integral magnetic stirrer; also 801 magnetic stirrer or 803 Ti Stand |
| Temperature sensor | Pt1000 |
| Connections | One remote connection (885 Compact Oven Sample Changer); one USB port; RS-232/USB Box optional |
| Auto start | Titration starts automatically when sample enters the vessel |
| Battery operation | Yes, with optional Power Box |
| Languages | German, English, French, Spanish, Italian, Portuguese |
| Dimensions | 144 x 112 x 282 mm |
| Ordering codes | 2.899.0010 with diaphragm generator electrode; 2.899.0110 without diaphragm; variants with printer, 860 KF Thermoprep or 885 oven changer |
How 899 Coulometer differs from other Metrohm coulometers
The 899 is the mobile, compact member of the coulometer range and offers the same capabilities as the larger instruments, including thermal sample preparation and full automation if needed. Its distinguishing points are the dimensions, the optional battery supply and the automatic start function. Where a 917 Coulometer or the bigger benchtop units add more connections, the Metrohm 899 Coulometer concentrates on portability and a small footprint with up to 100 stored methods and a live curve during titration.
Automatic start and the oven method
If a sample is added before the titration is started, conditioning continues until the cell is again titrated dry, so the water introduced by the sample is lost and the analysis has to be repeated. The automatic start of the 899 avoids this by starting the titration as soon as a sample enters the vessel. For samples that do not dissolve, react with the chemicals, release water slowly, release water only when hot, or would dirty the cell, the oven method is recommended: the sample is heated, a dry carrier gas carries the water into the cell, and the titration takes place there. The 899 can work with the manual 860 KF Thermoprep or the automated 885 Compact Oven Sample Changer.
Why coulometry for trace water
In volumetric Karl Fischer titration the iodine is added from a burette. In coulometric titration the iodine is generated electrochemically inside the cell at the generator electrode, and the amount of water is calculated from the electric charge needed to consume it. Because charge can be measured very precisely, the method is well suited to samples with very little water, which is why the 899 Coulometer starts at 10 micrograms. It needs no burette or titer determination, but it does depend on the cell solutions and a dry cell, so sample size, drift and cell condition matter. Keep sample volumes small enough that the cell is not overloaded, and use the oven for oils and solids that would contaminate the cell solution. Record the drift value before each determination and subtract it according to the method, since background moisture entering the cell from the air affects trace results more than any other factor. Seals, drying tubes and tubing should be checked at regular intervals, because even a small leak adds to the apparent water content.
Applications in Oman and the GCC
Typical uses in Gulf laboratories include water in transformer, hydraulic and lubricating oils, in fuels and solvents, in plastics granules via the oven, and in pharmaceutical and food materials. The mobile configuration also suits utilities that sample transformer oil at substations and want a result on site.
Working outside the laboratory
Carrying a coulometer to a substation or a storage tank only helps if the rest of the method travels with it. Pack sealed syringes for the sample, spare cell solution, a dry-tube refill and a clean towel, and set the instrument on a level surface away from wind and dust. Allow the cell to condition until the drift settles before the first determination, because a freshly moved cell often shows high drift. Take samples in dry, airtight containers, since oils pick up moisture from humid Gulf air within minutes, and report the sampling conditions together with the water result so that the reading can be interpreted properly later.
Operation and care of Metrohm 899 Coulometer
Condition the cell until the drift is stable, add the sample, and let the titration start automatically. Replace the cell solutions according to the manual, keep the generator electrode clean and store the Power Box charged. The instrument runs three predefined methods straight away, and the routine mode hides expert settings for operators who only need standard determinations.
Ordering notes for 899 Coulometer
Choose whether you need a generator electrode with or without diaphragm, the printer, the KF Thermoprep or the 885 oven changer, and add the Power Box if the unit must work off mains. Confirm the full code before ordering.
Related items you may also need: Metrohm 916 Ti-Touch Compact Potentiometric Titrator | Metrohm 905 Titrando Potentiometric Titrator | Metrohm 2035 Process Analyzer | All Metrohm products.
Documents and quotation
The manufacturer’s 899 Coulometer brochure is attached to this page as a datasheet. Send your RFQ with Metrohm 899 Coulometer, the ordering code, quantity and your delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Metrohm 899 Coulometer for Karl Fischer Water Determination Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.
Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.
Metrohm company profile
| Founded | 1943, Herisau, Switzerland |
|---|---|
| Founder | Bertold Suhner |
| Headquarters | Herisau, Switzerland |
| Ownership | Metrohm Foundation |
| Product families | Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes |
Metrohm instruments listed here
The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.
Metrohm products we list
| Family | Examples |
|---|---|
| Liquid Analytical Systems | 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr… |
Ordering Metrohm equipment: what we need
Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.
Facts checked against Metrohm's published company history, October 2026.
Browse Metrohm products by category: Liquid Analytical Systems.
FAQ
Questions about the Metrohm 899 Coulometer for Karl Fischer Water
Answers from our engineering team on installation, compatibility and integration.
01How small is the Metrohm 899 Coulometer?
It measures 144 x 112 x 282 mm, about the bench space of a sheet of A4 paper, and has an integral magnetic stirrer and cell holder.
02What water range does the 899 Coulometer cover?
The brochure gives a water content range of 10 micrograms to 200 milligrams, suitable for trace-level determinations.
03Can the 899 Coulometer run without mains power?
Yes. With the optional Power Box of rechargeable batteries it can run for hours of uninterrupted operation in the field.
04What does automatic start do on the 899 Coulometer?
It begins the titration as soon as the sample is placed in the vessel, avoiding repeated analyses when the start is forgotten.
05Can the 899 Coulometer use an oven?
Yes. It works with the manual 860 KF Thermoprep or the automated 885 Compact Oven Sample Changer for samples that cannot be added directly.