Brand: Metrohm
Metrohm 913 pH Meter Handheld IP67 pH Meter
Description
Overview
A handheld pH meter has to survive three environments: the field, the process area and the laboratory bench. The Metrohm 913 pH Meter is designed for all three. Seven Star LLC is an independent supplier serving Oman and the GCC. Metrohm’s brochure for the 912, 913 and 914 meters describes a family of handheld instruments certified to IP67, and the 913 pH Meter is the unit with two galvanically separated measuring inputs for pH, one analog and one digital. This page restates the brochure for environmental, water and process technicians.
What the Metrohm 913 pH Meter offers
The pH input resolves 0.001 pH units. Because two pH inputs are available, an analog electrode and a digital sensor can be connected at the same time, which lets a user compare two sensors in the same sample or run a check electrode alongside a working one. The meter can monitor calibration and the calibration interval and warns when recalibration is due. Calibration acceptance criteria can be set freely, and sensors can be managed in a sensor pool. Almost any Metrohm sensor can be connected, so an existing electrode inventory remains useful.
Results are saved with date, time, sample identification and user name, in two protected user levels, which supports GLP compliant documentation and prevents tampering with stored data. Notes can be stored with each measurement, for example sample location, and the meter detects automatically when the signal is stable so that reproducible readings are recorded.
Data table for Metrohm 913 pH Meter
| Item | Published information |
|---|---|
| Measuring inputs | Two galvanically separated pH inputs: analog and digital |
| pH resolution | 0.001 pH units |
| Ingress protection | IP67; complete submersion for up to 30 minutes without damage |
| Casing | Highly robust plastic, protects against drops from a height |
| Power | Battery for all-day use; can be recharged from a car or an external power bank |
| Data export | USB to PC as CSV or PC/LIMS format |
| Printing | Dot matrix, thermal and A4 printers supported |
| Data security | Two user levels with password protection |
| Calibration | Interval and acceptance criteria freely selectable |
| Carrying options | Compact carrying case; stand plate with support rod for bench use |
| Ordering codes | 2.913.0010 pH Meter; 2.913.0110 with Solidtrode with Pt1000 in carrying case; 2.913.0210 Lab with stand plate |
How 913 pH Meter differs from other Metrohm handheld meters
The brochure presents five variants. The 912 Conductometer measures conductivity from a few microsiemens per centimetre to 1000 millisiemens per centimetre. The 913 pH/DO Meter measures pH and dissolved oxygen in parallel. The 914 pH/Conductometer has two analog inputs for pH and conductivity at once, and the 914 pH/DO/Conductometer combines a digital input with an analog conductivity input. The Metrohm 913 pH Meter, in contrast, is the pH-only version with two pH inputs, and it is the one to buy when the question is pH accuracy, sensor comparison or documentation of pH calibration rather than conductivity or oxygen.
Working outdoors and in the process with 913 pH Meter
The meter is meant for field sampling, in situ process checks and laboratory work. For outdoor surveys of wells, ponds or effluent, the IP67 case and the all-day battery are the main advantages. In process areas, the quick pH check of a tank or line allows corrections before a batch is lost. In the laboratory, a stand plate with support rod turns the handheld into a bench meter. Typical Gulf uses include desalination and water treatment, cooling water chemistry, wastewater compliance sampling and food or beverage production.
Why two pH inputs are useful
Most handheld pH meters accept a single electrode. When a reading looks suspicious, the operator has no immediate way to tell whether the sample or the sensor is at fault. Having two measuring inputs that are electrically isolated from one another changes that. The user can place a digital sensor and an analog electrode in the same sample, compare the values, and see at once whether they agree. A second electrode also serves as a reference during field work, where it is not practical to return to the laboratory for a recalibration. The galvanic separation prevents the two sensors from disturbing each other, which can happen when two electrodes share the same liquid and the same ground path. The meter also keeps calibration data and the validity period for each sensor in its sensor pool, so the operator can see which electrodes are due for a check before leaving for site. These features support both quick troubleshooting and the documentation that environmental regulators and quality auditors expect.
Routine care of the Metrohm 913 pH Meter
Calibrate with fresh buffer solutions at the interval set in the meter, rinse the electrode between samples, and keep the electrode moist in the storage solution recommended by its maker. Wipe the case after use in the field and keep the connectors clean and dry. Back up stored measurements to a PC regularly through the USB interface. Replace the electrode when calibration slope falls outside your acceptance criteria.
Documentation and data integrity
Environmental and quality laboratories must show that a reading was taken with a calibrated meter by an identified user. The Metrohm 913 pH Meter stores each result together with date, time, sample name and user name, and the two password-protected user levels stop casual changes to stored data. Results can be printed on the spot or exported to a PC as a CSV file or in a format suitable for a laboratory information system. A field technician can therefore collect dozens of readings along a pipeline or across a site and hand over a complete electronic record at the end of the day instead of a handwritten sheet that needs retyping.
Ordering notes for 913 pH Meter
Choose between the meter alone, the set with a Solidtrode and Pt1000 in a carrying case, or the laboratory version with a stand plate. Add buffers, extra electrodes and a printer as needed. Please confirm the full ordering code before purchase.
Related items you may also need: Metrohm 916 Ti-Touch Compact Potentiometric Titrator | Metrohm 905 Titrando Potentiometric Titrator | Metrohm 2035 Process Analyzer | All Metrohm products.
Documents and quotation
The manufacturer’s brochure for the 912, 913 and 914 meters is attached to this page as a datasheet. Send your RFQ with Metrohm 913 pH Meter, quantity and delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Metrohm 913 pH Meter Handheld IP67 pH Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.
Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.
Metrohm company profile
| Founded | 1943, Herisau, Switzerland |
|---|---|
| Founder | Bertold Suhner |
| Headquarters | Herisau, Switzerland |
| Ownership | Metrohm Foundation |
| Product families | Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes |
Metrohm instruments listed here
The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.
Metrohm products we list
| Family | Examples |
|---|---|
| Liquid Analytical Systems | 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr… |
Ordering Metrohm equipment: what we need
Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.
Facts checked against Metrohm's published company history, October 2026.
Browse Metrohm products by category: Liquid Analytical Systems.
FAQ
Questions about the Metrohm 913 pH Meter Handheld IP67 pH Meter
Answers from our engineering team on installation, compatibility and integration.
01What does the Metrohm 913 pH Meter measure?
It measures pH with 0.001 resolution through two galvanically separated inputs, one analog and one digital, so two sensors can be used at once.
02Is the Metrohm 913 pH Meter waterproof?
It is certified to IP67, and the brochure states that complete submersion for up to 30 minutes causes no damage.
03How does the 913 pH Meter store and export data?
Results are saved with date, time, sample ID and user, and can be exported by USB as CSV or PC/LIMS files or printed directly.
04What ordering codes exist for the 913 pH Meter?
The brochure lists 2.913.0010 for the meter, 2.913.0110 with a Solidtrode with Pt1000 in a carrying case and 2.913.0210 as the lab version with stand plate.
05How does the 913 pH Meter differ from the 914?
The 914 pH/Conductometer adds a conductivity input alongside pH, while the 913 pH Meter is the pH-only version with two pH inputs.