Brand:

Yokogawa EJX530A-JBS8N-012DL Gauge Pressure, G1/2 Male

Description

Ready to bolt on: EJX530A-JBS8N-012DL

A transmitter that already has a display and a bracket can go straight onto a pipe stand and be read by operators. Yokogawa EJX530A-JBS8N-012DL comes that way: a B capsule gauge pressure transmitter with a span of 0.02 to 2 MPa, HART 5 or 7 output, a G1/2 DIN male process connection, a digital indicator, and a 316 SST two-inch pipe bracket. The housing is cast aluminum with two 1/2 NPT conduit entries.

Code detail for EJX530A-JBS8N-012DL

Code position Meaning
-J 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering)
B Capsule: span 0.02 to 2 MPa
S 316L SST process connector, Hastelloy C-276 diaphragm, 316L SST or F316L SST other wetted parts
8 Process connection: G1/2 DIN 16 288 male
1 Amplifier housing: cast aluminum alloy
2 Electrical: 1/2 NPT female, two electrical connections, no blind plugs
D Integral indicator: digital indicator
L Mounting bracket: 316 SST 2-inch pipe mounting bracket

Figures for the B capsule

Upper range limit and maximum working pressure are 2 MPa (290 psig), over-pressure is 4 MPa and burst pressure is 30 MPa. Reference accuracy is plus or minus 0.04 percent of span from a span of 0.2 MPa upward; stability is plus or minus 0.1 percent of URL over fifteen years. Response time is 90 ms and the update period 45 ms. The range extends to minus 0.1 MPa, useful for suction lines. Ambient and process temperature limits are minus 40 to 85 degrees C and minus 40 to 120 degrees C, narrowed to minus 30 to 80 degrees C ambient by the LCD.

Output, diagnostics and safety data of EJX530A-JBS8N-012DL

Output is 3.6 to 21.6 mA with a configurable failure alarm at 110 percent or minus 5 percent. A 10-segment signal characterizer can be set by the user. The self-diagnostic list includes CPU and hardware failure, configuration errors and process alarms for pressure and capsule temperature. Without options the EJX530A in HART or BRAIN form is certified for SIL 2 capability for single use and SIL 3 for dual-transmitter use under IEC 61508, whereas the fieldbus versions are outside that certification. Local parameter setting through the external zero screw and push button covers loop test, tag, unit, LRV, URV, damping, output mode and display. Supply is 10.5 to 42 V DC with a 250 ohm minimum for HART communication.

Reference data for EJX530A-JBS8N-012DL

Item Value
Capsule B 0.02 to 2 MPa gauge; URL 2 MPa
Thread G1/2 DIN 16 288 male
Indicator D, digital LCD
Bracket L, 316 SST 2-inch pipe
Output 4 to 20 mA, HART 5/7
Housing Cast aluminum alloy
Electrical 1/2 NPT female x2
Over-pressure 4 MPa
Burst 30 MPa
Response 90 ms
Weight 1.2 kg before indicator and bracket

Use cases

Pump discharge pressure on cooling water and fire water systems, filter and strainer supervision, steam header pressure at low levels, air receivers and process air. G1/2 male ports are common on skids built in Europe and the Far East, which is why this code appears in spare lists on imported packages. Two megapascals is a convenient ceiling for most utility lines at industrial sites in the Gulf.

Selection notes for EJX530A-JBS8N-012DL

If your tapping is NPT, choose the 4 or 7 process connection. If you want push-button range setting, choose indicator code E instead of D. If the line may be exposed to pressure surges above 4 MPa, upgrade to the C capsule that withstands 20 MPa. The DIN male thread is described in the datasheet as based on the withdrawn DIN 16 288; ask your supplier of fittings which sealing washer matches your female counterpart.

Installation of EJX530A-JBS8N-012DL

Clamp the bracket on a 2-inch pipe, thread the connector into the mating fitting with a suitable sealing washer, wire through one 1/2 NPT entry and plug the other. Check the loop with at least 250 ohm of resistance if you use HART, and adjust the zero screw once the transmitter is hanging at its final angle.

Compare the LCD reading with a reference gauge once a year and look at the diagnostics through a HART host. If the reading drifts beyond the fifteen-year stability band, schedule a recalibration.

Spare covers, amplifier assemblies and indicators follow the EJX family rather than the capsule, so stocking one LCD module and a pair of cover O-rings covers all variants of EJX530A-JBS8N-012DL and its relatives.

Quick answers about EJX530A-JBS8N-012DL

  • What does the L suffix give on EJX530A-JBS8N-012DL? A 316 SST bracket for 2-inch pipe mounting, supplied with the transmitter.
  • Which thread does code 8 select? G1/2 DIN 16 288 male, a parallel pipe thread that should be sealed with a washer or gasket.
  • What span can I set on the B capsule? Between 0.02 and 2 MPa, with a lower range limit of minus 0.1 MPa gauge.
  • Is there a local display? Yes. D gives a digital indicator that can show pressure in percent, scaled pressure and measured pressure.
  • How accurate is it? Plus or minus 0.04 percent of span for spans of 0.2 MPa and above, per the datasheet.

Documents and quotation

Mention thread type and bracket when ordering.

The Yokogawa general specification GS 01C25F01-01EN, which covers the EJX510A and EJX530A, is supplied as the datasheet PDF with this listing. To request a quotation, send the part number EJX530A-JBS8N-012DL, the quantity, tag numbers, process fluid and the approval you need if the area is classified. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Availability and lead time are confirmed per RFQ.

Spares and Lifecycle Considerations

For critical service, many plants hold one Yokogawa EJX530A-JBS8N-012DL as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical pressure transmitters units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.

Other Models in the EJX530A Range

Seven Star LLC supplies models from the EJX530A range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa EJX530A-DAS4N-012NN Gauge Pressure TransmitterPressure TransmittersView details
Yokogawa EJX530A-JBS8N-012DL Gauge Pressure, G1/2 MalePressure TransmittersYou are viewing this model
Yokogawa EJX530A-JCH4N-032EL Hastelloy Gauge PressurePressure TransmittersView details
Datasheets & Documents
  • PDF Datasheet Yokogawa EJX530A-JBS8N-012DL Gauge Pressure, G1/2 Male Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJX530A-JBS8N-012DL Gauge Pressure, G1/2

Answers from our engineering team on installation, compatibility and integration.

01What does the L suffix give on EJX530A-JBS8N-012DL?
A 316 SST bracket for 2-inch pipe mounting, supplied with the transmitter.
02Which thread does code 8 select?
G1/2 DIN 16 288 male, a parallel pipe thread that should be sealed with a washer or gasket.
03What span can I set on the B capsule?
Between 0.02 and 2 MPa, with a lower range limit of minus 0.1 MPa gauge.
04Is there a local display?
Yes. D gives a digital indicator that can show pressure in percent, scaled pressure and measured pressure.
05How accurate is it?
Plus or minus 0.04 percent of span for spans of 0.2 MPa and above, per the datasheet.