Brand:

Hydac HDA 478G-A-0200-DV-000 Ex d Transmitter, 1/4 NPT Male

Description

Hydac HDA 478G-A-0200-DV-000 screws straight into a female 1/4-18 NPT port and delivers 4 to 20 mA from 0 to 200 psi. That male-thread feature is why plant engineers ask for it by name: gauge tees, block valves and manifold test points in North American style hydraulics almost always present a female NPT port. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

The HDA 478G-A-0200-DV-000 at a glance

The housing is 316L stainless, the wetted parts are the 1.45xx and 1.43xx grades listed by the manufacturer and the seal is FKM. A flameproof conduit connection of 1/2-14 NPT carries the open cable. The weight is 0.661 lb, which is light enough to hang on the cable without strain relief in a bench test.

A practical point on this part: because the thread is male, the transmitter can be fitted into a standard pipe-thread tee or a block with a 1/4 NPT female port without a nipple, and the 40 N·m tightening value is applied at the hex nearest the thread rather than on the housing. The two flying leads that matter are white and brown; the spare green and yellow ends should be insulated and folded back, not connected to a shield or earth, because the manufacturer lists them as not used.

Feature list

  • Male 1/4-18 NPT, 40 N·m tightening value.
  • White/brown flying leads; green and yellow spare.
  • Accuracy 0.25 percent FS, hysteresis 0.1 percent FS, repeatability 0.05 percent FS.
  • Rise time 1.5 ms or less.
  • Operating pressure 200 psi, overload 1160 psi, burst 2900 psi.
  • Ex d I Mb / Ex d IIC T6, T5 Gb / Ex tb IIIC Db.

Specification table, HDA 478G-A-0200-DV-000

Parameter Value
Model code HDA 478G-A-0200-DV-000
Material number (catalog) 923033
Measuring range 0 to 200 psi
Overload pressure 1160 psi
Burst pressure 2900 psi
Cell type Vented gauge (V)
Process connection 1/4-18 NPT, male
Tightening torque 30 lb-ft (40 N·m)
Electrical connection 1/2-14 NPT conduit, open-ended cable
Cores / cable 72 in. cable per catalog code; white signal plus, brown signal minus, green and yellow not used
Output 4 to 20 mA, 2-wire, load RLmax = (UB – 8 V) / 20 mA in kOhm
Supply voltage 8 to 30 V DC, residual ripple 5 percent or less, about 25 mA
Accuracy (terminal based) 0.25 percent FS typical and maximum; best-fit line 0.15 percent typical
Non-linearity / hysteresis / repeatability 0.3 / 0.1 / 0.05 percent FS maximum
Temperature coefficient (zero, span) 0.008 percent FS per degC typical, 0.015 maximum
Rise time / long-term drift 1.5 ms or less / 0.1 percent FS per year
Wetted parts Stainless steel 1.4542, 1.4571, 1.4435, 1.4404, 1.4301; FKM seal
Housing / conduit 1.4404 and 1.4435 (316L)
Compensated temperature T5 / T130: -13 to 176 degF; T6 / T110: -13 to 140 degF
Operating and fluid temperature T5: -4 to 176 degF; T6: -4 to 140 degF (FKM seal)
Storage temperature -40 to 212 degF
Protection IP 65 (vented gauge)
Vibration 20 g, 10 to 500 Hz
Weight 0.661 lb (about 300 g)
Approvals ATEX KEMA 10ATEX100 X; CSA MC 224264; IECEx KEM 10.0053X

Applications

Typical places include pump skid gauge tees on mining dewatering rigs, hydraulic test stands in explosion-risk workshops and drive-end panels on valve actuation stations. In a gas processing plant the unit measures instrument-air or seal-gas pressure within classified boxes, where HDA 478G-A-0200-DV-000 sends its current to a safe-area marshalling cabinet.

How HDA 478G-A-0200-DV-000 differs from other HDA 47xx Ex d versions

The relevant comparison is the thread gender. 478G-A-0200 is male 1/4 NPT; 47FG-A-0200 is female 1/4 NPT with an otherwise identical wiring scheme. The 478G-A-0300 sister raises the range to 300 psi with the same overload of 1160 psi. The 477G variant changes the port to SAE 6 and the torque to 20 N·m. For HDA 478G-A-0200-DV-000, all four share the same housing and certificates.

Selection

Pick this version when the mating port is female NPT. Confirm the fluid is compatible with stainless steel and FKM, and select a larger range if peaks exceed roughly five times the span. A 200 psi device is suited to circuits that stay below 200 psi in normal operation.

Installation

Wrap threads with a compatible sealant, thread the male stub into the female port and tighten the hex to 40 N·m. Terminate the white and brown cores in a certified enclosure, insulate the unused green and yellow ends and power the loop from 8 to 30 V DC. Check zero and span before commissioning HDA 478G-A-0200-DV-000.

Service and care

There is no wearing part. Annual calibration checks against a gauge are enough. If HDA 478G-A-0200-DV-000 is exposed to repeated pressure shock, review the range choice before blaming the sensor.

When replacing an obsolete transmitter, compare range, thread gender and wiring before quoting HDA 478G-A-0200-DV-000. We read the order key back to you in writing.

Spares and Lifecycle Considerations

For critical service, many plants hold one Hydac HDA 478G-A-0200-DV-000 as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical pressure transmitters units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.

Frequently asked questions about HDA 478G-A-0200-DV-000

What does the 8 in 478G stand for? The eighth position of the mechanical code selects a 1/4-18 NPT male process connection, while F would be female.

How is the output connected? White is signal plus and brown is signal minus on the flying leads. Green and yellow cores are not used.

What is the burst pressure of HDA 478G-A-0200-DV-000? The catalog gives 2900 psi, with 1160 psi overload and a maximum operating pressure of 200 psi.

What torque should I use? The catalog lists 40 N·m (30 lb-ft) for the 1/4 NPT thread.

Where do I send an enquiry? Send an RFQ with HDA 478G-A-0200-DV-000, quantity and delivery location to Seven Star LLC.

Documents and quotation

Attached: the datasheet for HDA 478G-A-0200-DV-000. Send an RFQ with the part number HDA 478G-A-0200-DV-000, quantity and destination to receive availability and delivery time.

Datasheets & Documents
  • PDF Datasheet Hydac HDA 478G-A-0200-DV-000 Ex d Transmitter, 1/4 NPT Male Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac HDA 478G-A-0200-DV-000 Ex d Transmitter, 1/4

Answers from our engineering team on installation, compatibility and integration.

01What does the 8 in 478G stand for?
The eighth position of the mechanical code selects a 1/4-18 NPT male process connection, while F would be female.
02How is the output connected?
White is signal plus and brown is signal minus on the flying leads. Green and yellow cores are not used.
03What is the burst pressure of HDA 478G-A-0200-DV-000?
The catalog gives 2900 psi, with 1160 psi overload and a maximum operating pressure of 200 psi.
04What torque should I use?
The catalog lists 40 N·m (30 lb-ft) for the 1/4 NPT thread.
05Where do I send an enquiry?